Article: Practical evaluation of dimming control methods for electronic ballasts

TitlePractical evaluation of dimming control methods for electronic ballasts
Authors
KeywordsDimmable electronic ballasts
Dimming methods
Issue Date2006
PublisherIEEE
Citation
Ieee Transactions On Power Electronics, 2006, v. 21 n. 6, p. 1769-1775 How to Cite?
AbstractThe authors compare and evaluate 1) the traditional frequency-control dimming method and 2) a recently-patented voltage-control dimming method in electronic ballasts for fluorescent lamps. The power factor, energy efficiency, electronic loss, efficacy (lumen/W), and crest factor of 2 × 36 W electronic ballasts based on these two dimming methods are recorded and compared over a wide dimming range. It is found that the voltage dimming control approach is much better than the frequency control method in most of the compared aspects as the lamp is dimmed. In particular, voltage dimming approach has much higher energy efficiency and lumen per watt than the frequency control one. Unlike the frequency dimming method, voltage dimming control has a distinctive feature in that its electronic loss decreases with decreasing lamp power. © 2006 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/136964
ISSN
2021 Impact Factor: 5.967
2020 SCImago Journal Rankings: 2.159
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorTam, PWen_HK
dc.contributor.authorLee, STSen_HK
dc.contributor.authorHui, SYRen_HK
dc.contributor.authorChung, HSHen_HK
dc.date.accessioned2011-07-29T02:13:50Z-
dc.date.available2011-07-29T02:13:50Z-
dc.date.issued2006en_HK
dc.identifier.citationIeee Transactions On Power Electronics, 2006, v. 21 n. 6, p. 1769-1775en_HK
dc.identifier.issn0885-8993en_HK
dc.identifier.urihttp://hdl.handle.net/10722/136964-
dc.description.abstractThe authors compare and evaluate 1) the traditional frequency-control dimming method and 2) a recently-patented voltage-control dimming method in electronic ballasts for fluorescent lamps. The power factor, energy efficiency, electronic loss, efficacy (lumen/W), and crest factor of 2 × 36 W electronic ballasts based on these two dimming methods are recorded and compared over a wide dimming range. It is found that the voltage dimming control approach is much better than the frequency control method in most of the compared aspects as the lamp is dimmed. In particular, voltage dimming approach has much higher energy efficiency and lumen per watt than the frequency control one. Unlike the frequency dimming method, voltage dimming control has a distinctive feature in that its electronic loss decreases with decreasing lamp power. © 2006 IEEE.en_HK
dc.languageengen_US
dc.publisherIEEEen_US
dc.relation.ispartofIEEE Transactions on Power Electronicsen_HK
dc.subjectDimmable electronic ballastsen_HK
dc.subjectDimming methodsen_HK
dc.titlePractical evaluation of dimming control methods for electronic ballastsen_HK
dc.typeArticleen_HK
dc.identifier.emailHui, SYR:ronhui@eee.hku.hken_HK
dc.identifier.authorityHui, SYR=rp01510en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/TPEL.2006.882914en_HK
dc.identifier.scopuseid_2-s2.0-37849186702en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-37849186702&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume21en_HK
dc.identifier.issue6en_HK
dc.identifier.spage1769en_HK
dc.identifier.epage1775en_HK
dc.identifier.isiWOS:000241965100028-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridTam, PW=7202539475en_HK
dc.identifier.scopusauthoridLee, STS=35468613000en_HK
dc.identifier.scopusauthoridHui, SYR=7202831744en_HK
dc.identifier.scopusauthoridChung, HSH=7404007467en_HK
dc.identifier.issnl0885-8993-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats