File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Fast response low harmonic distortion control scheme for voltage source inverters

TitleFast response low harmonic distortion control scheme for voltage source inverters
Authors
Issue Date2009
Citation
Iet Power Electronics, 2009, v. 2 n. 5, p. 574-584 How to Cite?
AbstractA fast response low harmonic distortion control scheme is proposed that combines the useful features of the sliding mode control and the repetitive control to achieve excellent transient and steady-state system performances in voltage source inverters. The principle of s domain equivalent control is adopted to integrate the two methodologies and to facilitate the design and analysis of the proposed scheme. An optional specific low-pass filter can be introduced into the system to improve the transient response of the regulation. Experimental results show that fast dynamic responses are achieved through the sliding mode control, whereas low harmonic distortions are achieved through the repetitive control. © 2009 The Institution of Engineering and Technology.
Persistent Identifierhttp://hdl.handle.net/10722/148908
ISSN
2021 Impact Factor: 2.112
2020 SCImago Journal Rankings: 0.637
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorChen, Sen_HK
dc.contributor.authorLai, YMen_HK
dc.contributor.authorTan, SCen_HK
dc.contributor.authorTse, CKen_HK
dc.date.accessioned2012-06-20T06:16:15Z-
dc.date.available2012-06-20T06:16:15Z-
dc.date.issued2009en_HK
dc.identifier.citationIet Power Electronics, 2009, v. 2 n. 5, p. 574-584en_HK
dc.identifier.issn1755-4535en_HK
dc.identifier.urihttp://hdl.handle.net/10722/148908-
dc.description.abstractA fast response low harmonic distortion control scheme is proposed that combines the useful features of the sliding mode control and the repetitive control to achieve excellent transient and steady-state system performances in voltage source inverters. The principle of s domain equivalent control is adopted to integrate the two methodologies and to facilitate the design and analysis of the proposed scheme. An optional specific low-pass filter can be introduced into the system to improve the transient response of the regulation. Experimental results show that fast dynamic responses are achieved through the sliding mode control, whereas low harmonic distortions are achieved through the repetitive control. © 2009 The Institution of Engineering and Technology.en_HK
dc.languageengen_US
dc.relation.ispartofIET Power Electronicsen_HK
dc.titleFast response low harmonic distortion control scheme for voltage source invertersen_HK
dc.typeArticleen_HK
dc.identifier.emailTan, SC:sctan@hku.hken_HK
dc.identifier.authorityTan, SC=rp01606en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1049/iet-pel.2008.0149en_HK
dc.identifier.scopuseid_2-s2.0-77956002206en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-77956002206&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume2en_HK
dc.identifier.issue5en_HK
dc.identifier.spage574en_HK
dc.identifier.epage584en_HK
dc.identifier.isiWOS:000276385100011-
dc.identifier.scopusauthoridChen, S=41861162700en_HK
dc.identifier.scopusauthoridLai, YM=7401512093en_HK
dc.identifier.scopusauthoridTan, SC=26642772000en_HK
dc.identifier.scopusauthoridTse, CK=7103295097en_HK
dc.identifier.issnl1755-4535-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats