File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: 3-D MEMS based real-time minimally invasive endoscopic optical coherence tomography

Title3-D MEMS based real-time minimally invasive endoscopic optical coherence tomography
Authors
Issue Date2005
Citation
Ieee/Leos Optical Mems 2005: International Conference On Optical Mems And Their Applications, 2005, p. 25-26 How to Cite?
AbstractA 3-dimensional, endoscopic optical coherence tomography (OCT) system based on a high-speed micromachined scanning mirror is presented. Cross sectional images of in-vitro and in-vivo samples are obtained and continuously displayed to the user. The optical resolution of the system is approximately 20μm×20μm×10μm. The endosrealtiescopie OCT probe has been utilized to identify cancerous regions of hamster cheek pouch tissue in real-time. © 2005 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/149017
References

 

DC FieldValueLanguage
dc.contributor.authorMcCormick, DTen_HK
dc.contributor.authorJung, Wen_HK
dc.contributor.authorMilanović, Ven_HK
dc.contributor.authorChen, Zen_HK
dc.contributor.authorTien, NCen_HK
dc.date.accessioned2012-06-20T06:17:53Z-
dc.date.available2012-06-20T06:17:53Z-
dc.date.issued2005en_HK
dc.identifier.citationIeee/Leos Optical Mems 2005: International Conference On Optical Mems And Their Applications, 2005, p. 25-26en_US
dc.identifier.urihttp://hdl.handle.net/10722/149017-
dc.description.abstractA 3-dimensional, endoscopic optical coherence tomography (OCT) system based on a high-speed micromachined scanning mirror is presented. Cross sectional images of in-vitro and in-vivo samples are obtained and continuously displayed to the user. The optical resolution of the system is approximately 20μm×20μm×10μm. The endosrealtiescopie OCT probe has been utilized to identify cancerous regions of hamster cheek pouch tissue in real-time. © 2005 IEEE.en_HK
dc.languageengen_US
dc.relation.ispartofIEEE/LEOS Optical MEMS 2005: International Conference on Optical MEMS and Their Applicationsen_HK
dc.title3-D MEMS based real-time minimally invasive endoscopic optical coherence tomographyen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailTien, NC: nctien@hku.hken_HK
dc.identifier.authorityTien, NC=rp01604en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/OMEMS.2005.1540058en_HK
dc.identifier.scopuseid_2-s2.0-33749068462en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33749068462&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.spage25en_HK
dc.identifier.epage26en_HK
dc.identifier.scopusauthoridMcCormick, DT=7202521902en_HK
dc.identifier.scopusauthoridJung, W=7201622408en_HK
dc.identifier.scopusauthoridMilanović, V=7006511466en_HK
dc.identifier.scopusauthoridChen, Z=7409482950en_HK
dc.identifier.scopusauthoridTien, NC=7006532826en_HK

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats