Conference Paper: Fault tolerant control of harmonic injected nine-phase flux switching permanent magnet motor drive system

TitleFault tolerant control of harmonic injected nine-phase flux switching permanent magnet motor drive system
Authors
Issue Date2014
PublisherIEEE. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/conhome.jsp?punumber=1000234
Citation
The 17th International Conference on Electrical Machines and Systems (ICEMS 2014), Hangzhou, China, 22-25 October 2014. In Conference Proceedings, 2014, p. 3117-3122 How to Cite?
AbstractIn this paper, a universal online generation technique of non-sinusoidal fault-tolerant current is proposed for a nine-phase flux switching permanent magnet (NP-FSPM) motor with third harmonic back electromotive force (EMF) under single phase open-circuit fault condition. The decoupled model of NP-FSPM motor has been developed. By calculating the average torque and the pulsating torque components in steady state, the condition for reducing the torque ripple is analyzed, and the third harmonic current injection can be kept constant in the pre- and post open-circuit fault condition. The predicted results are confirmed by simulation. © 2014 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/217353
ISBN

 

DC FieldValueLanguage
dc.contributor.authorYu, F-
dc.contributor.authorCheng, M-
dc.contributor.authorLi, F-
dc.contributor.authorChau, KT-
dc.contributor.authorHuang, J-
dc.contributor.authorHua, W-
dc.date.accessioned2015-09-18T05:57:09Z-
dc.date.available2015-09-18T05:57:09Z-
dc.date.issued2014-
dc.identifier.citationThe 17th International Conference on Electrical Machines and Systems (ICEMS 2014), Hangzhou, China, 22-25 October 2014. In Conference Proceedings, 2014, p. 3117-3122-
dc.identifier.isbn978-1-4799-5162-8-
dc.identifier.urihttp://hdl.handle.net/10722/217353-
dc.description.abstractIn this paper, a universal online generation technique of non-sinusoidal fault-tolerant current is proposed for a nine-phase flux switching permanent magnet (NP-FSPM) motor with third harmonic back electromotive force (EMF) under single phase open-circuit fault condition. The decoupled model of NP-FSPM motor has been developed. By calculating the average torque and the pulsating torque components in steady state, the condition for reducing the torque ripple is analyzed, and the third harmonic current injection can be kept constant in the pre- and post open-circuit fault condition. The predicted results are confirmed by simulation. © 2014 IEEE.-
dc.languageeng-
dc.publisherIEEE. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/conhome.jsp?punumber=1000234-
dc.relation.ispartofInternational Conference on Electrical Machines and Systems (ICEMS)-
dc.titleFault tolerant control of harmonic injected nine-phase flux switching permanent magnet motor drive system-
dc.typeConference_Paper-
dc.identifier.emailChau, KT: ktchau@eee.hku.hk-
dc.identifier.authorityChau, KT=rp00096-
dc.description.naturelink_to_subscribed_fulltext-