File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: In vitro experiment to elucidate the mechanism of the ‘soft shell technique’ for preventing subretinal migration of perfluoro-octane

TitleIn vitro experiment to elucidate the mechanism of the ‘soft shell technique’ for preventing subretinal migration of perfluoro-octane
Authors
KeywordsExperimental – laboratory
Posterior Chamber
Retina
Treatment Surgery
Issue Date2017
PublisherBMJ Publishing Group. The Journal's web site is located at http://bjo.bmjjournals.com/
Citation
British Journal of Ophthalmology, 2017, v. 101 n. 3, p. 389-394 How to Cite?
AbstractAim: Perfluorocarbon liquid (PFCL) can migrate into subretinal space in detached and stiffened retina with open holes during vitreoretinal surgery. An innovative ‘soft shell’ technique was introduced to reduce the complication using hyaluronate (HA) to ‘cover’ the retinal hole. This study aims to study the effectiveness of this technique in vitro. Methods: Ex vivo porcine retina was mounted on a transwell insert. Beneath the retina was an aqueous solution. Two retinal holes were made using needle punctures. One of the two retinal holes was covered with HA. Perfluoro-n-octane (PFO) was added above the retina incrementally using a syringe pump. The height of PFO required to cause the migration of PFO through the retinal holes was measured. The ‘pendant drop’ method was carried out to measure the interfacial tensions between the PFO and aqueous, and between PFO and four different concentrations of HA solution. Results: A statistically higher PFO level was required to cause the migration of PFO through the retinal hole with HA coating than without HA coating (Tobit regression with p<0.05). The use of HA was associated with 2.39-fold increase in hydrostatic pressure before the collapse of the PFO interface at the retinal holes. The interfacial tension between PFO and HA solution with concentrations of 0.05%, 0.25%, 0.5% and 1% were 54.2±0.6, 55.3±0.6, 59.5±1.5 and 68.3±1.3 mN/m, respectively (mean±SD). The interfacial tension between PFO and aqueous with 1% HA coating (68.3±1.3 mN/m) was significantly higher than that without (37.4±3.4 mN/m) (p<0.05). Conclusions: The interfacial tension between HA and PFO is higher than that between aqueous and PFO. This is a plausible physical explanation of how the ‘soft shell’ technique might work to prevent subretinal migration of PFCL.
Persistent Identifierhttp://hdl.handle.net/10722/245062
ISSN
2021 Impact Factor: 5.908
2020 SCImago Journal Rankings: 2.016
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChan, YK-
dc.contributor.authorLu, Y-
dc.contributor.authorCzanner, G-
dc.contributor.authorWu, J-
dc.contributor.authorCheng, HC-
dc.contributor.authorHussain, R-
dc.contributor.authorSakamoto, T-
dc.contributor.authorShum, HC-
dc.contributor.authorWong, DSH-
dc.date.accessioned2017-09-18T02:03:57Z-
dc.date.available2017-09-18T02:03:57Z-
dc.date.issued2017-
dc.identifier.citationBritish Journal of Ophthalmology, 2017, v. 101 n. 3, p. 389-394-
dc.identifier.issn0007-1161-
dc.identifier.urihttp://hdl.handle.net/10722/245062-
dc.description.abstractAim: Perfluorocarbon liquid (PFCL) can migrate into subretinal space in detached and stiffened retina with open holes during vitreoretinal surgery. An innovative ‘soft shell’ technique was introduced to reduce the complication using hyaluronate (HA) to ‘cover’ the retinal hole. This study aims to study the effectiveness of this technique in vitro. Methods: Ex vivo porcine retina was mounted on a transwell insert. Beneath the retina was an aqueous solution. Two retinal holes were made using needle punctures. One of the two retinal holes was covered with HA. Perfluoro-n-octane (PFO) was added above the retina incrementally using a syringe pump. The height of PFO required to cause the migration of PFO through the retinal holes was measured. The ‘pendant drop’ method was carried out to measure the interfacial tensions between the PFO and aqueous, and between PFO and four different concentrations of HA solution. Results: A statistically higher PFO level was required to cause the migration of PFO through the retinal hole with HA coating than without HA coating (Tobit regression with p<0.05). The use of HA was associated with 2.39-fold increase in hydrostatic pressure before the collapse of the PFO interface at the retinal holes. The interfacial tension between PFO and HA solution with concentrations of 0.05%, 0.25%, 0.5% and 1% were 54.2±0.6, 55.3±0.6, 59.5±1.5 and 68.3±1.3 mN/m, respectively (mean±SD). The interfacial tension between PFO and aqueous with 1% HA coating (68.3±1.3 mN/m) was significantly higher than that without (37.4±3.4 mN/m) (p<0.05). Conclusions: The interfacial tension between HA and PFO is higher than that between aqueous and PFO. This is a plausible physical explanation of how the ‘soft shell’ technique might work to prevent subretinal migration of PFCL.-
dc.languageeng-
dc.publisherBMJ Publishing Group. The Journal's web site is located at http://bjo.bmjjournals.com/-
dc.relation.ispartofBritish Journal of Ophthalmology-
dc.rightsBritish Journal of Ophthalmology. Copyright © BMJ Publishing Group.-
dc.subjectExperimental – laboratory-
dc.subjectPosterior Chamber-
dc.subjectRetina-
dc.subjectTreatment Surgery-
dc.titleIn vitro experiment to elucidate the mechanism of the ‘soft shell technique’ for preventing subretinal migration of perfluoro-octane-
dc.typeArticle-
dc.identifier.emailChan, YK: josephyk@connect.hku.hk-
dc.identifier.emailShum, HC: ashum@hku.hk-
dc.identifier.authorityChan, YK=rp02536-
dc.identifier.authorityShum, HC=rp01439-
dc.identifier.authorityWong, DSH=rp00516-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1136/bjophthalmol-2016-309856-
dc.identifier.pmid28057648-
dc.identifier.scopuseid_2-s2.0-85009453052-
dc.identifier.hkuros276816-
dc.identifier.volume101-
dc.identifier.issue3-
dc.identifier.spage389-
dc.identifier.epage394-
dc.identifier.isiWOS:000395536600027-
dc.publisher.placeUnited Kingdom-
dc.identifier.issnl0007-1161-

Export via OAI-PMH Interface in XML Formats