File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Short electrode insertion in cochlear implantation: Speech perception performance of Cantonese-speaking subjects

TitleShort electrode insertion in cochlear implantation: Speech perception performance of Cantonese-speaking subjects
Authors
KeywordsCochlear implant
Cochlear ossification
Electrode insertion
Meningitis
Issue Date2005
PublisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/00016489.asp
Citation
Acta Oto-Laryngologica, 2005, v. 125 n. 7, p. 718-724 How to Cite?
AbstractConclusions. Subjects with cochlear ossification derived benefits in terms of speech performance similar to those of the nonossified group. It is thus recommended that the insertion of short electrode arrays should be considered an alternative choice for patients with cochlear ossification. Objective. Cochlear ossification has been recognized as a major obstacle to the full insertion of a multichannel cochlear implant electrode array. To alleviate the technical difficulty of placing a standard electrode array and the possibility of causing undesirable trauma to the cochlea, a newly designed electrode array with the same number of electrodes compressed into a shorter length has been made available. The aim of the present study was to examine the speech perception performance of patients implanted with the MED-EL C40 + S compressed electrode array and to compare their results with those of matched groups implanted with the MED-EL C40 + standard electrode array. Material and methods. One pre-lingually and two post-lingually deaf subjects using short electrode arrays were matched with three groups of subjects using standard electrode arrays. The pre- and postoperative speech perception scores were evaluated. Results. All three subjects using compressed electrode arrays achieved speech perception scores comparable to those of matched subjects using standard electrode arrays. There was also a tendency for the subjects to show similar patterns of speech perception scores as a function of the difficulty of the tests. © 2005 Taylor & Francis.
Persistent Identifierhttp://hdl.handle.net/10722/83964
ISSN
2021 Impact Factor: 1.698
2020 SCImago Journal Rankings: 0.609
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorChu, KMYen_HK
dc.contributor.authorAu, DKKen_HK
dc.contributor.authorHui, Yen_HK
dc.contributor.authorChow, CKen_HK
dc.contributor.authorWei, WIen_HK
dc.date.accessioned2010-09-06T08:47:19Z-
dc.date.available2010-09-06T08:47:19Z-
dc.date.issued2005en_HK
dc.identifier.citationActa Oto-Laryngologica, 2005, v. 125 n. 7, p. 718-724en_HK
dc.identifier.issn0001-6489en_HK
dc.identifier.urihttp://hdl.handle.net/10722/83964-
dc.description.abstractConclusions. Subjects with cochlear ossification derived benefits in terms of speech performance similar to those of the nonossified group. It is thus recommended that the insertion of short electrode arrays should be considered an alternative choice for patients with cochlear ossification. Objective. Cochlear ossification has been recognized as a major obstacle to the full insertion of a multichannel cochlear implant electrode array. To alleviate the technical difficulty of placing a standard electrode array and the possibility of causing undesirable trauma to the cochlea, a newly designed electrode array with the same number of electrodes compressed into a shorter length has been made available. The aim of the present study was to examine the speech perception performance of patients implanted with the MED-EL C40 + S compressed electrode array and to compare their results with those of matched groups implanted with the MED-EL C40 + standard electrode array. Material and methods. One pre-lingually and two post-lingually deaf subjects using short electrode arrays were matched with three groups of subjects using standard electrode arrays. The pre- and postoperative speech perception scores were evaluated. Results. All three subjects using compressed electrode arrays achieved speech perception scores comparable to those of matched subjects using standard electrode arrays. There was also a tendency for the subjects to show similar patterns of speech perception scores as a function of the difficulty of the tests. © 2005 Taylor & Francis.en_HK
dc.languageengen_HK
dc.publisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/00016489.aspen_HK
dc.relation.ispartofActa Oto-Laryngologicaen_HK
dc.rightsActa Oto-Laryngologica. Copyright © Informa Healthcare.-
dc.rights99138-
dc.subjectCochlear implanten_HK
dc.subjectCochlear ossificationen_HK
dc.subjectElectrode insertionen_HK
dc.subjectMeningitisen_HK
dc.titleShort electrode insertion in cochlear implantation: Speech perception performance of Cantonese-speaking subjectsen_HK
dc.typeArticleen_HK
dc.identifier.emailAu, DKK: kinkwau@hkucc.hku.hken_HK
dc.identifier.emailWei, WI: hrmswwi@hku.hken_HK
dc.identifier.authorityAu, DKK=rp00385en_HK
dc.identifier.authorityWei, WI=rp00323en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1080/00016480410024640en_HK
dc.identifier.pmid16012033-
dc.identifier.scopuseid_2-s2.0-22944469720en_HK
dc.identifier.hkuros116842en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-22944469720&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume125en_HK
dc.identifier.issue7en_HK
dc.identifier.spage718en_HK
dc.identifier.epage724en_HK
dc.identifier.isiWOS:000230505000007-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridChu, KMY=37039113900en_HK
dc.identifier.scopusauthoridAu, DKK=7004909224en_HK
dc.identifier.scopusauthoridHui, Y=7103107552en_HK
dc.identifier.scopusauthoridChow, CK=10641126300en_HK
dc.identifier.scopusauthoridWei, WI=7403321552en_HK
dc.identifier.citeulike255043-
dc.identifier.issnl0001-6489-

Export via OAI-PMH Interface in XML Formats


OR