File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Effect of static loading of dentin beams at various pH levels

TitleEffect of static loading of dentin beams at various pH levels
Authors
KeywordsChemicals And Cas Registry Numbers
Issue Date2006
PublisherSpringer New York LLC. The Journal's web site is located at http://link.springer.de/link/service/journals/00223
Citation
Calcified Tissue International, 2006, v. 79 n. 6, p. 416-421 How to Cite?
AbstractNoncarious cervical lesions have a multifactorial etiology. Mechanical stress has been identified as one of the factors, but little evidence exists for its cause-effect relationship. This study was conducted at three different pH levels to observe the surface loss on dentin beams under tension and compression. Bovine dentin beams (10 x 3.75 x 1.45 mm) were fixed at one end and immersed in 0.1 M lactic acid solution at pH levels 4.5 (n = 20), 7 (n = 20), and 10 (n = 20) for 5 days under a load of 6.5 N (663 g). The mean surface loss was more on the surface under compression than that under tension at pH 4.5 and pH 7 than at pH 10. Also, the surface loss on the beams decreased as the distance from the fixed end increased. It was concluded that stress and lower pH both increase surface loss at the fixed end of the beam, which in a tooth represents the cervical region. © 2006 Springer Science+Business Media, Inc.
Persistent Identifierhttp://hdl.handle.net/10722/90695
ISSN
2021 Impact Factor: 4.000
2020 SCImago Journal Rankings: 1.078
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorMishra, Pen_HK
dc.contributor.authorPalamara, JEAen_HK
dc.contributor.authorTyas, MJen_HK
dc.contributor.authorBurrow, MFen_HK
dc.date.accessioned2010-09-17T10:06:55Z-
dc.date.available2010-09-17T10:06:55Z-
dc.date.issued2006en_HK
dc.identifier.citationCalcified Tissue International, 2006, v. 79 n. 6, p. 416-421en_HK
dc.identifier.issn0171-967Xen_HK
dc.identifier.urihttp://hdl.handle.net/10722/90695-
dc.description.abstractNoncarious cervical lesions have a multifactorial etiology. Mechanical stress has been identified as one of the factors, but little evidence exists for its cause-effect relationship. This study was conducted at three different pH levels to observe the surface loss on dentin beams under tension and compression. Bovine dentin beams (10 x 3.75 x 1.45 mm) were fixed at one end and immersed in 0.1 M lactic acid solution at pH levels 4.5 (n = 20), 7 (n = 20), and 10 (n = 20) for 5 days under a load of 6.5 N (663 g). The mean surface loss was more on the surface under compression than that under tension at pH 4.5 and pH 7 than at pH 10. Also, the surface loss on the beams decreased as the distance from the fixed end increased. It was concluded that stress and lower pH both increase surface loss at the fixed end of the beam, which in a tooth represents the cervical region. © 2006 Springer Science+Business Media, Inc.en_HK
dc.languageengen_HK
dc.publisherSpringer New York LLC. The Journal's web site is located at http://link.springer.de/link/service/journals/00223en_HK
dc.relation.ispartofCalcified Tissue Internationalen_HK
dc.subjectChemicals And Cas Registry Numbersen_HK
dc.subject.meshAnimalsen_HK
dc.subject.meshCattleen_HK
dc.subject.meshCompressive Strengthen_HK
dc.subject.meshDental Stress Analysis - methodsen_HK
dc.subject.meshDentin - chemistry - drug effects - physiologyen_HK
dc.subject.meshHydrogen-Ion Concentrationen_HK
dc.subject.meshIncisoren_HK
dc.subject.meshLactic Acid - chemistry - pharmacologyen_HK
dc.subject.meshModels, Biologicalen_HK
dc.subject.meshStress, Mechanicalen_HK
dc.subject.meshSurface Properties - drug effectsen_HK
dc.subject.meshWeight-Bearing - physiologyen_HK
dc.titleEffect of static loading of dentin beams at various pH levelsen_HK
dc.typeArticleen_HK
dc.identifier.emailBurrow, MF:mfburr58@hku.hken_HK
dc.identifier.authorityBurrow, MF=rp01306en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1007/s00223-005-0271-9en_HK
dc.identifier.pmid17160580-
dc.identifier.scopuseid_2-s2.0-33845863391en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33845863391&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume79en_HK
dc.identifier.issue6en_HK
dc.identifier.spage416en_HK
dc.identifier.epage421en_HK
dc.identifier.isiWOS:000242851900006-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridMishra, P=54970793400en_HK
dc.identifier.scopusauthoridPalamara, JEA=7003676720en_HK
dc.identifier.scopusauthoridTyas, MJ=7006088443en_HK
dc.identifier.scopusauthoridBurrow, MF=7005876730en_HK
dc.identifier.citeulike1037399-
dc.identifier.issnl0171-967X-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats