Article: Rate responsive pacing with a minute ventilation sensing pacemaker during pregnancy and delivery
Title | Rate responsive pacing with a minute ventilation sensing pacemaker during pregnancy and delivery |
---|---|
Authors | |
Keywords | cesarean section minute ventilation pregnancy rate responsive pacing |
Issue Date | 1990 |
Citation | PACE - Pacing and Clinical Electrophysiology, 1990, v. 13 n. 2, p. 158-163 How to Cite? |
Abstract | A minute ventilation sensing rate responsive pacemaker was implanted in a 29-week pregnant woman with symptomatic complete atrioventricular (AV) block under echocardiographic and electrocardiographic (ECG) guidance. Satisfactory rate responses during a submaximal treadmill exercise test and daily activities were achieved. The course of pregnancy and cesarean section is discussed. During the cesarean section and after the delivery of the baby, changes in the ventilator settings confirmed that the pacing rate was closely correlated with both the tidal volume (r = 0.94, P < 0.01) and the respiratory rate (r = 0.93, P < 0.05). |
Persistent Identifier | http://hdl.handle.net/10722/194093 |
ISSN | 2023 Impact Factor: 1.7 2023 SCImago Journal Rankings: 0.579 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lau, C-P | - |
dc.contributor.author | Lee, C-P | - |
dc.contributor.author | Wong, C-K | - |
dc.contributor.author | Cheng, C-H | - |
dc.contributor.author | Leung, W-H | - |
dc.date.accessioned | 2014-01-30T03:32:09Z | - |
dc.date.available | 2014-01-30T03:32:09Z | - |
dc.date.issued | 1990 | - |
dc.identifier.citation | PACE - Pacing and Clinical Electrophysiology, 1990, v. 13 n. 2, p. 158-163 | - |
dc.identifier.issn | 0147-8389 | - |
dc.identifier.uri | http://hdl.handle.net/10722/194093 | - |
dc.description.abstract | A minute ventilation sensing rate responsive pacemaker was implanted in a 29-week pregnant woman with symptomatic complete atrioventricular (AV) block under echocardiographic and electrocardiographic (ECG) guidance. Satisfactory rate responses during a submaximal treadmill exercise test and daily activities were achieved. The course of pregnancy and cesarean section is discussed. During the cesarean section and after the delivery of the baby, changes in the ventilator settings confirmed that the pacing rate was closely correlated with both the tidal volume (r = 0.94, P < 0.01) and the respiratory rate (r = 0.93, P < 0.05). | - |
dc.language | eng | - |
dc.relation.ispartof | PACE - Pacing and Clinical Electrophysiology | - |
dc.subject | cesarean section | - |
dc.subject | minute ventilation | - |
dc.subject | pregnancy | - |
dc.subject | rate responsive pacing | - |
dc.title | Rate responsive pacing with a minute ventilation sensing pacemaker during pregnancy and delivery | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1111/j.1540-8159.1990.tb05065.x | - |
dc.identifier.pmid | 1689831 | - |
dc.identifier.scopus | eid_2-s2.0-0025072194 | - |
dc.identifier.volume | 13 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 158 | - |
dc.identifier.epage | 163 | - |
dc.identifier.isi | WOS:A1990DC49800006 | - |
dc.identifier.issnl | 0147-8389 | - |