Article: Effect of inter-module connections on progressive collapse behaviour of MiC structures
Title | Effect of inter-module connections on progressive collapse behaviour of MiC structures |
---|---|
Authors | |
Keywords | Component approach Failure modes Inter-module connections, beam-column joint MiC structures Progressive collapse |
Issue Date | 2021 |
Citation | Journal of Constructional Steel Research, 2021, v. 185, article no. 106823 How to Cite? |
Abstract | Modular integrated Construction (MiC) is a game changing construction approach which could significantly increase construction efficiency, quality, and sustainability. For steel MiC structures, modules are manufactured in the factories and assembled at the construction sites through inter-module connections. The concern of the vulnerability of these connections under abnormal hazards leading to disproportionate progressive collapse will impede industrial applications of MiC structures in the construction community. This study investigates the structural robustness of corner-supported modular steel buildings with the focus on different inter-module connections. A sub-structure extracted from a five-storey modular building is analysed by high fidelity finite element analysis under a corner column removal scenario. The load redistribution mechanism and failure modes are investigated thoroughly, based on which the simplified macro model is proposed where connections are modelled with rotational springs. Good consistence is found for the simplified model and the detailed FE analysis in terms of the pushdown curve. It is also found that the inter-module connection types will affect the beam-column joint properties which dominate the progressive collapse resistance of MiC structures. Therefore, attention should be paid when selecting different inter-module connections. The current rigid beam-column joint connection may lead to nonconservative evaluation. |
Persistent Identifier | http://hdl.handle.net/10722/349577 |
ISSN | 2023 Impact Factor: 4.0 2023 SCImago Journal Rankings: 1.261 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | He, Xiao Huang Can | - |
dc.contributor.author | Chan, Tak Ming | - |
dc.contributor.author | Chung, Kwok Fai | - |
dc.date.accessioned | 2024-10-17T06:59:27Z | - |
dc.date.available | 2024-10-17T06:59:27Z | - |
dc.date.issued | 2021 | - |
dc.identifier.citation | Journal of Constructional Steel Research, 2021, v. 185, article no. 106823 | - |
dc.identifier.issn | 0143-974X | - |
dc.identifier.uri | http://hdl.handle.net/10722/349577 | - |
dc.description.abstract | Modular integrated Construction (MiC) is a game changing construction approach which could significantly increase construction efficiency, quality, and sustainability. For steel MiC structures, modules are manufactured in the factories and assembled at the construction sites through inter-module connections. The concern of the vulnerability of these connections under abnormal hazards leading to disproportionate progressive collapse will impede industrial applications of MiC structures in the construction community. This study investigates the structural robustness of corner-supported modular steel buildings with the focus on different inter-module connections. A sub-structure extracted from a five-storey modular building is analysed by high fidelity finite element analysis under a corner column removal scenario. The load redistribution mechanism and failure modes are investigated thoroughly, based on which the simplified macro model is proposed where connections are modelled with rotational springs. Good consistence is found for the simplified model and the detailed FE analysis in terms of the pushdown curve. It is also found that the inter-module connection types will affect the beam-column joint properties which dominate the progressive collapse resistance of MiC structures. Therefore, attention should be paid when selecting different inter-module connections. The current rigid beam-column joint connection may lead to nonconservative evaluation. | - |
dc.language | eng | - |
dc.relation.ispartof | Journal of Constructional Steel Research | - |
dc.subject | Component approach | - |
dc.subject | Failure modes | - |
dc.subject | Inter-module connections, beam-column joint | - |
dc.subject | MiC structures | - |
dc.subject | Progressive collapse | - |
dc.title | Effect of inter-module connections on progressive collapse behaviour of MiC structures | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.jcsr.2021.106823 | - |
dc.identifier.scopus | eid_2-s2.0-85109557672 | - |
dc.identifier.volume | 185 | - |
dc.identifier.spage | article no. 106823 | - |
dc.identifier.epage | article no. 106823 | - |