Article: Biomechanical comparison of 4 fixation techniques of sacral pedicle screw in osteoporotic condition
Title | Biomechanical comparison of 4 fixation techniques of sacral pedicle screw in osteoporotic condition | ||||||
---|---|---|---|---|---|---|---|
Authors | |||||||
Keywords | biomechanics lumbosacral fusion osteoporosis polymethylmethacrylate sacral pediclescrew | ||||||
Issue Date | 2010 | ||||||
Publisher | Lippincott Williams & Wilkins. The Journal's web site is located at http://www.jspinaldisorders-tech.com | ||||||
Citation | Journal Of Spinal Disorders And Techniques, 2010, v. 23 n. 6, p. 404-409 How to Cite? | ||||||
Abstract | Objectives: To compare the subsidence displacement after cyclic loading among 4 sacral pedicle screw fixations of bicortical, tricortical, standard polymethylmethacrylate (PMMA) augmentation, and sub-endplate PMMA augmentation in osteoporotic condition. Summary of background data: Implant failure caused by screw loosening is a clinical problem for lumbosacral fusions, especially in osteoporotic patients. To improve sacral screw anchoring strength, the main fixation techniques need to be evaluated biomechanically. Methods: For this study, 11 fresh osteoporotic cadaver sacra were harvested and bone mineral density was measured with dual-energy radiograph absorptiometry. A 7mm diameter monoaxial pedicle screw (S1) was randomly assigned by side (left vs. right) and placed bicortically or tricortically. The 2 screws, followed 2000 cyclic compression loading of 30 to 250N, were removed. The screw tracts were filled up with PMMA, then, screws 5mm shorter than the bicortical or tricortical fixation were reinserted (defined as standard and sub-endplate PMMA augmented sacral screw fixations, respectively). The PMMA augmented screws were then retested as before. Screw subsidence displacement after 2000 cyclic loading was measured and compared. Results: The average bone mineral density of 11 specimens was 0.71g/cm, ranged from 0.65 to 0.78g/cm. No significant difference of subsidence displacement was detected between tricortical and standard PMMA augmented screws (P>0.05), however, the 2 fixations exhibited markedly less subsidence than bicortical screw (P<0.05). Sub-endplate PMMA augmented screw showed the least subsidence among all the screws (P<0.05). Conclusions: PMMA augmentation can increase the bonding strength of sacral screw-bone interface and the sub-endplate PMMA augmented sacral screw could obtain the highest stability among the 4 fixation techniques in osteoporotic condition. © 2010 by Lippincott Williams & Wilkins. | ||||||
Persistent Identifier | http://hdl.handle.net/10722/125175 | ||||||
ISSN | 2017 Impact Factor: 2.310 2019 SCImago Journal Rankings: 1.401 | ||||||
ISI Accession Number ID |
Funding Information: Partial support received from HKRGC (715306/06E) and GDSTC (2008B050100012). | ||||||
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yu, BS | en_HK |
dc.contributor.author | Zhuang, XM | en_HK |
dc.contributor.author | Zheng, ZM | en_HK |
dc.contributor.author | Zhang, JF | en_HK |
dc.contributor.author | Li, ZM | en_HK |
dc.contributor.author | Lu, WW | en_HK |
dc.date.accessioned | 2010-10-31T11:15:42Z | - |
dc.date.available | 2010-10-31T11:15:42Z | - |
dc.date.issued | 2010 | en_HK |
dc.identifier.citation | Journal Of Spinal Disorders And Techniques, 2010, v. 23 n. 6, p. 404-409 | en_HK |
dc.identifier.issn | 1536-0652 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/125175 | - |
dc.description.abstract | Objectives: To compare the subsidence displacement after cyclic loading among 4 sacral pedicle screw fixations of bicortical, tricortical, standard polymethylmethacrylate (PMMA) augmentation, and sub-endplate PMMA augmentation in osteoporotic condition. Summary of background data: Implant failure caused by screw loosening is a clinical problem for lumbosacral fusions, especially in osteoporotic patients. To improve sacral screw anchoring strength, the main fixation techniques need to be evaluated biomechanically. Methods: For this study, 11 fresh osteoporotic cadaver sacra were harvested and bone mineral density was measured with dual-energy radiograph absorptiometry. A 7mm diameter monoaxial pedicle screw (S1) was randomly assigned by side (left vs. right) and placed bicortically or tricortically. The 2 screws, followed 2000 cyclic compression loading of 30 to 250N, were removed. The screw tracts were filled up with PMMA, then, screws 5mm shorter than the bicortical or tricortical fixation were reinserted (defined as standard and sub-endplate PMMA augmented sacral screw fixations, respectively). The PMMA augmented screws were then retested as before. Screw subsidence displacement after 2000 cyclic loading was measured and compared. Results: The average bone mineral density of 11 specimens was 0.71g/cm, ranged from 0.65 to 0.78g/cm. No significant difference of subsidence displacement was detected between tricortical and standard PMMA augmented screws (P>0.05), however, the 2 fixations exhibited markedly less subsidence than bicortical screw (P<0.05). Sub-endplate PMMA augmented screw showed the least subsidence among all the screws (P<0.05). Conclusions: PMMA augmentation can increase the bonding strength of sacral screw-bone interface and the sub-endplate PMMA augmented sacral screw could obtain the highest stability among the 4 fixation techniques in osteoporotic condition. © 2010 by Lippincott Williams & Wilkins. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Lippincott Williams & Wilkins. The Journal's web site is located at http://www.jspinaldisorders-tech.com | en_HK |
dc.relation.ispartof | Journal of Spinal Disorders and Techniques | en_HK |
dc.subject | biomechanics | en_HK |
dc.subject | lumbosacral fusion | en_HK |
dc.subject | osteoporosis | en_HK |
dc.subject | polymethylmethacrylate | en_HK |
dc.subject | sacral pediclescrew | en_HK |
dc.subject.mesh | Aged | - |
dc.subject.mesh | Aged, 80 and over | - |
dc.subject.mesh | Osteoporosis - physiopathology - surgery | - |
dc.subject.mesh | Sacrum - physiopathology - surgery | - |
dc.subject.mesh | Spinal Fusion - instrumentation - methods | - |
dc.title | Biomechanical comparison of 4 fixation techniques of sacral pedicle screw in osteoporotic condition | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1536-0652&volume=23&issue=6&spage=404&epage=409&date=2010&atitle=Biomechanical+comparison+of+4+fixation+techniques+of+sacral+pedicle+screw+in+osteoporotic+condition | en_HK |
dc.identifier.email | Lu, WW:wwlu@hku.hk | en_HK |
dc.identifier.authority | Lu, WW=rp00411 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1097/BSD.0b013e3181b63f4d | en_HK |
dc.identifier.pmid | 20087222 | - |
dc.identifier.scopus | eid_2-s2.0-77955459474 | en_HK |
dc.identifier.hkuros | 180220 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-77955459474&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 23 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 404 | en_HK |
dc.identifier.epage | 409 | en_HK |
dc.identifier.isi | WOS:000280575000008 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Yu, BS=25633299000 | en_HK |
dc.identifier.scopusauthorid | Zhuang, XM=35436325900 | en_HK |
dc.identifier.scopusauthorid | Zheng, ZM=7403007434 | en_HK |
dc.identifier.scopusauthorid | Zhang, JF=35098035200 | en_HK |
dc.identifier.scopusauthorid | Li, ZM=36168413000 | en_HK |
dc.identifier.scopusauthorid | Lu, WW=7404215221 | en_HK |
dc.identifier.issnl | 1536-0652 | - |