File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1002/jmri.22245
- Scopus: eid_2-s2.0-77955365667
- PMID: 20677256
- WOS: WOS:000280447300008
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers
Title | International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers | ||||||||
---|---|---|---|---|---|---|---|---|---|
Authors | |||||||||
Keywords | Cardiac siderosis Cardiomyopathy Cardiovascular MR Thalassemia | ||||||||
Issue Date | 2010 | ||||||||
Publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www.interscience.wiley.com/jpages/1053-1807/ | ||||||||
Citation | Journal Of Magnetic Resonance Imaging, 2010, v. 32 n. 2, p. 315-319 How to Cite? | ||||||||
Abstract | Purpose: To examine the reproducibility of the single breathhold T2* technique fromdifferent scanners, after installation of standardmethodology in five international centers. Materials and Methods: Up to 10 patients from each center were scanned twice locally for local interstudy reproducibility of heart and liver T2*, and then flown to a central MR facility to be rescanned on a reference scanner for intercenter reproducibility. Interobserver reproducibility for all scans was also assessed. Results: Of the 49 patients scanned, the intercenter reproducibility for T2* was 5.9% for the heart and 5.8% for the liver. Local interstudy reproducibility for T2* was 7.4% for the heart and 4.6% for the liver. Interobserver reproducibility for T2* was 5.4% for the heart and 4.4% for the liver. Conclusion: These data indicate that T2* MR may be developed into a widespread test for tissue siderosis providing that well-defined and approved imaging and analysis techniques are used. © 2010 Wiley-Liss, Inc. | ||||||||
Persistent Identifier | http://hdl.handle.net/10722/125231 | ||||||||
ISSN | 2023 Impact Factor: 3.3 2023 SCImago Journal Rankings: 1.339 | ||||||||
PubMed Central ID | |||||||||
ISI Accession Number ID |
Funding Information: Contract grant sponsor: National Institutes of Health; Contract grant number: 5 R01 DK066084-02 | ||||||||
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kirk, P | en_HK |
dc.contributor.author | He, T | en_HK |
dc.contributor.author | Anderson, LJ | en_HK |
dc.contributor.author | Roughton, M | en_HK |
dc.contributor.author | Tanner, MA | en_HK |
dc.contributor.author | Lam, WWM | en_HK |
dc.contributor.author | Au, WY | en_HK |
dc.contributor.author | Chu, WCW | en_HK |
dc.contributor.author | Chan, G | en_HK |
dc.contributor.author | Galanello, R | en_HK |
dc.contributor.author | Matta, G | en_HK |
dc.contributor.author | Fogel, M | en_HK |
dc.contributor.author | Cohen, AR | en_HK |
dc.contributor.author | Tan, RS | en_HK |
dc.contributor.author | Chen, K | en_HK |
dc.contributor.author | Ng, I | en_HK |
dc.contributor.author | Lai, A | en_HK |
dc.contributor.author | Fucharoen, S | en_HK |
dc.contributor.author | Laothamata, J | en_HK |
dc.contributor.author | Chuncharunee, S | en_HK |
dc.contributor.author | Jongjirasiri, S | en_HK |
dc.contributor.author | Firmin, DN | en_HK |
dc.contributor.author | Smith, GC | en_HK |
dc.contributor.author | Pennell, DJ | en_HK |
dc.date.accessioned | 2010-10-31T11:18:54Z | - |
dc.date.available | 2010-10-31T11:18:54Z | - |
dc.date.issued | 2010 | en_HK |
dc.identifier.citation | Journal Of Magnetic Resonance Imaging, 2010, v. 32 n. 2, p. 315-319 | en_HK |
dc.identifier.issn | 1053-1807 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/125231 | - |
dc.description.abstract | Purpose: To examine the reproducibility of the single breathhold T2* technique fromdifferent scanners, after installation of standardmethodology in five international centers. Materials and Methods: Up to 10 patients from each center were scanned twice locally for local interstudy reproducibility of heart and liver T2*, and then flown to a central MR facility to be rescanned on a reference scanner for intercenter reproducibility. Interobserver reproducibility for all scans was also assessed. Results: Of the 49 patients scanned, the intercenter reproducibility for T2* was 5.9% for the heart and 5.8% for the liver. Local interstudy reproducibility for T2* was 7.4% for the heart and 4.6% for the liver. Interobserver reproducibility for T2* was 5.4% for the heart and 4.4% for the liver. Conclusion: These data indicate that T2* MR may be developed into a widespread test for tissue siderosis providing that well-defined and approved imaging and analysis techniques are used. © 2010 Wiley-Liss, Inc. | en_HK |
dc.language | eng | en_HK |
dc.publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www.interscience.wiley.com/jpages/1053-1807/ | en_HK |
dc.relation.ispartof | Journal of Magnetic Resonance Imaging | en_HK |
dc.rights | Journal of Magnetic Resonance Imaging. Copyright © John Wiley & Sons, Inc. | - |
dc.subject | Cardiac siderosis | en_HK |
dc.subject | Cardiomyopathy | en_HK |
dc.subject | Cardiovascular MR | en_HK |
dc.subject | Thalassemia | en_HK |
dc.title | International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1053-1807&volume=32&issue=2&spage=315&epage=319&date=2010&atitle=International+reproducibility+of+single+breathhold+T2*+MR+for+cardic+and+liver+iron+assessment+among+five+thalassemia+centers | - |
dc.identifier.email | Chan, G:gcfchan@hkucc.hku.hk | en_HK |
dc.identifier.authority | Chan, G=rp00431 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1002/jmri.22245 | en_HK |
dc.identifier.pmid | 20677256 | - |
dc.identifier.pmcid | PMC2946327 | - |
dc.identifier.scopus | eid_2-s2.0-77955365667 | en_HK |
dc.identifier.hkuros | 179097 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-77955365667&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 32 | en_HK |
dc.identifier.issue | 2 | en_HK |
dc.identifier.spage | 315 | en_HK |
dc.identifier.epage | 319 | en_HK |
dc.identifier.isi | WOS:000280447300008 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Kirk, P=24474747700 | en_HK |
dc.identifier.scopusauthorid | He, T=34570131700 | en_HK |
dc.identifier.scopusauthorid | Anderson, LJ=7403741602 | en_HK |
dc.identifier.scopusauthorid | Roughton, M=24067576200 | en_HK |
dc.identifier.scopusauthorid | Tanner, MA=13907612900 | en_HK |
dc.identifier.scopusauthorid | Lam, WWM=13410486800 | en_HK |
dc.identifier.scopusauthorid | Au, WY=7202383089 | en_HK |
dc.identifier.scopusauthorid | Chu, WCW=7402227871 | en_HK |
dc.identifier.scopusauthorid | Chan, G=16160154400 | en_HK |
dc.identifier.scopusauthorid | Galanello, R=7004292185 | en_HK |
dc.identifier.scopusauthorid | Matta, G=6506763913 | en_HK |
dc.identifier.scopusauthorid | Fogel, M=7102455134 | en_HK |
dc.identifier.scopusauthorid | Cohen, AR=7404780851 | en_HK |
dc.identifier.scopusauthorid | Tan, RS=7201984906 | en_HK |
dc.identifier.scopusauthorid | Chen, K=36458173600 | en_HK |
dc.identifier.scopusauthorid | Ng, I=46461891700 | en_HK |
dc.identifier.scopusauthorid | Lai, A=36458559200 | en_HK |
dc.identifier.scopusauthorid | Fucharoen, S=7103089590 | en_HK |
dc.identifier.scopusauthorid | Laothamata, J=36242024200 | en_HK |
dc.identifier.scopusauthorid | Chuncharunee, S=6701490020 | en_HK |
dc.identifier.scopusauthorid | Jongjirasiri, S=8562774500 | en_HK |
dc.identifier.scopusauthorid | Firmin, DN=7007100394 | en_HK |
dc.identifier.scopusauthorid | Smith, GC=35467183800 | en_HK |
dc.identifier.scopusauthorid | Pennell, DJ=7103221771 | en_HK |
dc.identifier.issnl | 1053-1807 | - |