Article: ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group
Title | ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group |
---|---|
Authors | |
Keywords | Medicine & Public Health Cardiology |
Issue Date | 2010 |
Publisher | Springer Netherlands |
Citation | The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging), 2010, v. 26, p. 203-212 How to Cite? |
Abstract | The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. © 2010 The Author(s). |
Persistent Identifier | http://hdl.handle.net/10722/145031 |
ISSN | 2023 Impact Factor: 1.5 2023 SCImago Journal Rankings: 0.694 |
ISI Accession Number ID | |
References | Matsuo S, Imai E, Horio M et al (2009) Revised equations for estimated GFR from serum creatinine in Japan. Am J Kidney Dis 53(6):982–992 doi: 10.1053/j.ajkd.2008.12.034 Ma Y, Zuo L, Chen JH et al (2006) Modified glomerular filtration rate estimating equation for Chinese patients with chronic kidney disease. J Am Soc Nephrol 17(10):2937–2944 doi: 10.1681/ASN.2006040368 Fleischmann D, Kamaya A (2009) Optimal vascular and parenchymal contrast enhancement: the current state of the art. Radiol Clin North Am 47(1):13–26 doi: 10.1016/j.rcl.2008.10.009 Cademartiri F, van der Lugt A, Luccichenti G et al (2002) Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr 26(4):598–607 doi: 10.1097/00004728-200207000-00022 Becker CR, Hong C, Knez A et al (2003) Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 38(11):690–694 doi: 10.1097/01.rli.0000084886.44676.e4 Cademartiri F, Mollet NR, Lemos PA et al (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187(4):W430–W433 doi: 10.2214/AJR.05.1406 Cademartiri F, Maffei E, Palumbo AA et al (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18(3):576–583 doi: 10.1007/s00330-007-0773-0 Cademartiri F, Mollet NR, van der Lugt A et al (2005) Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 236(2):661–665 doi: 10.1148/radiol.2362040468 Rist C, Nikolaou K, Kirchin MA et al (2006) Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. Invest Radiol 41(5):460–467 doi: 10.1097/01.rli.0000208239.34723.5d Tatsugami F, Kanamoto T, Nakai G et al (2010) Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography. Br J Radiol 83(985):35–39 doi: 10.1259/bjr/23203690 Tatsugami F, Matsuki M, Inada Y et al (2010) Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography. Acad Radiol 17(2):207–211 doi: 10.1016/j.acra.2009.09.010 Mitsumori LM, Wang E, May JM et al (2010) Triphasic contrast bolus for whole-chest ECG-gated 64-MDCT of patients with nonspecific chest pain: evaluation of arterial enhancement and streak artifact. AJR Am J Roentgenol 194(3):W263–W271 doi: 10.2214/AJR.09.2788 Litmanovich D, Zamboni GA, Hauser TH et al (2008) ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain. Eur Radiol 18(2):308–317 doi: 10.1007/s00330-007-0739-2 Ishida M, Sakuma H, Murashima S et al (2009) Absolute blood contrast concentration and blood signal saturation on myocardial perfusion MRI: estimation from CT data. J Magn Reson Imag 29(1):205–210 doi: 10.1002/jmri.21470 Webb JA, Thomsen HS, Morcos SK (2005) Members of Contrast Media Safety Committee of European Society of Urogenital Radiology (ESUR). The use of iodinated and gadolinium contrast media during pregnancy and lactation. Eur Radiol 15(6):1234–1240 doi: 10.1007/s00330-004-2583-y Sakuma H, Ichikawa Y, Chino S et al (2006) Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. J Am Coll Cardiol 48(10):1946–1950 doi: 10.1016/j.jacc.2006.07.055 Wang CL, Cohan RH, Ellis JH et al (2007) Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69, 657 intravenous injections. Radiology 243(1):80–87 doi: 10.1148/radiol.2431060554 Dillman JR, Strouse PJ, Ellis JH et al (2007) Incidence and severity of acute allergic-like reactions to i.v nonionic iodinated contrast material in children. AJR Am J Roentgenol 188(6):1643–1647 doi: 10.2214/AJR.06.1328 Wang CL, Cohan RH, Ellis JH et al (2008) Frequency, outcome, and appropriateness of treatment of nonionic iodinated contrast media reactions. AJR Am J Roentgenol 191(2):409–415 doi: 10.2214/AJR.07.3421 Herborn CU, Honold E, Wolf M et al (2007) Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA). Invest Radiol 42(1):58–62 doi: 10.1097/01.rli.0000248893.01067.e5 Bleicher AG, Kanal E (2008) Assessment of adverse reaction rates to a newly approved MRI contrast agent: review of 23,553 administrations of gadobenate dimeglumine. Am J Roentgenol 191(6):W307–W311 doi: 10.2214/AJR.07.3951 Christiansen C, Pichler WJ, Skotland T (2000) Delayed allergy-like reactions to X-ray contrast media: mechanistic considerations. Eur Radiol 10(12):1965–1975 doi: 10.1007/s003300000543 Cockcroft DW, Gault MH (1976) Prediction of creatinine clearance from serum creatinine. Nephron 16(1):31–41 doi: 10.1159/000180580 Hafez T (2007) Modification of diet in renal disease (MDRD) estimated glomerular filtration rate (eGFR) formula. Am J Cardiol 99(4):584 doi: 10.1016/j.amjcard.2006.10.013 Solomon R, Werner C, Mann D et al (1994) Effects of saline, mannitol, and furosemide to prevent acute decreases in renal function induced by radiocontrast agents. N Engl J Med 331(21):1416–1420 doi: 10.1056/NEJM199411243312104 Solomon RJ, Natarajan MK, Doucet S et al (2007) Cardiac angiography in renally impaired patients (CARE) study: a randomized double-blind trial of contrast-induced nephropathy in patients with chronic kidney disease. Circulation 115(25):3189–3196 doi: 10.1161/CIRCULATIONAHA.106.671644 Baker CS, Wragg A, Kumar S et al (2003) A rapid protocol for the prevention of contrast-induced renal dysfunction: the RAPPID study. J Am Coll Cardiol 41(12):2114–2118 doi: 10.1016/S0735-1097(03)00487-X Ferrario F, Barone MT, Landoni G et al (2009) Acetylcysteine and non-ionic isosmolar contrast-induced nephropathy–a randomized controlled study. Nephrol Dial Transpl 24(10):3103–3107 doi: 10.1093/ndt/gfp306 Kanter MZ (2006) Comparison of oral and i.v. acetylcysteine in the treatment of acetaminophen poisoning. Am J Health Syst Pharm 63(19):1821–1827 doi: 10.2146/ajhp060050 Schweiger MJ, Chambers CE, Davidson CJ et al (2007) Prevention of contrast induced nephropathy: recommendations for the high risk patient undergoing cardiovascular procedures. Catheter Cardiovasc Interv 69(1):135–140 doi: 10.1002/ccd.20964 Grobner T (2006) Gadolinium—a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? Nephrol Dial Transpl 21(4):1104–1108 doi: 10.1093/ndt/gfk062 Perazella MA (2009) Current status of gadolinium toxicity in patients with kidney disease. Clin J Am Soc Nephrol 4(2):461–469 doi: 10.2215/CJN.06011108 Marckmann P, Skov L, Rossen K et al (2006) Nephrogenic systemic fibrosis: suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging. J Am Soc Nephrol 17(9):2359–2362 doi: 10.1681/ASN.2006060601 Prince MR, Zhang H, Morris M et al (2008) Incidence of nephrogenic systemic fibrosis at two large medical centers. Radiology 248(3):807–816 doi: 10.1148/radiol.2483071863 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | ASCI CCT & CMR Guideline Working Group | en_US |
dc.contributor.author | Jinzaki, M | en_US |
dc.contributor.author | Kitagawa, K | en_US |
dc.contributor.author | Tsai, IC | en_US |
dc.contributor.author | Chan, C | en_US |
dc.contributor.author | Yu, W | en_US |
dc.contributor.author | Yong, HS | en_US |
dc.contributor.author | Choi, BW | en_US |
dc.date.accessioned | 2012-02-21T05:42:56Z | - |
dc.date.available | 2012-02-21T05:42:56Z | - |
dc.date.issued | 2010 | en_US |
dc.identifier.citation | The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging), 2010, v. 26, p. 203-212 | en_US |
dc.identifier.issn | 1569-5794 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/145031 | - |
dc.description.abstract | The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. © 2010 The Author(s). | en_US |
dc.language | eng | en_US |
dc.publisher | Springer Netherlands | en_US |
dc.relation.ispartof | The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging) | en_US |
dc.rights | The Author(s) | en_US |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | en_US |
dc.subject | Medicine & Public Health | en_US |
dc.subject | Cardiology | en_US |
dc.title | ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group | en_US |
dc.type | Article | en_US |
dc.identifier.openurl | http://library.hku.hk:4551/resserv?sid=springerlink&genre=article&atitle=ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group&title=The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging)&issn=15695794&date=2010-12-01&volume=26&issue=0& spage=203&authors=ASCI CCT & CMR Guideline Working Group, Masahiro Jinzaki, Kakuya Kitagawa, <i>et al.</i> | en_US |
dc.description.nature | published_or_final_version | en_US |
dc.identifier.doi | 10.1007/s10554-010-9691-3 | en_US |
dc.identifier.pmid | 20931289 | - |
dc.identifier.scopus | eid_2-s2.0-78650511346 | en_US |
dc.relation.references | American College of Radiology Manual on Contrast Media v7 http://www.acr.org/SecondaryMainMenuCategories/quality_safety/contrast_manual.aspx | en_US |
dc.relation.references | ESUR Guidelines on Contrast media (2006) Ver 6.0 http://www.esur.org/fileadmin/Guidelines/ESUR_2007_Guideline_6_Kern_Ubersicht.pdf | en_US |
dc.relation.references | Matsuo S, Imai E, Horio M et al (2009) Revised equations for estimated GFR from serum creatinine in Japan. Am J Kidney Dis 53(6):982–992 | en_US |
dc.relation.references | doi: 10.1053/j.ajkd.2008.12.034 | en_US |
dc.relation.references | Ma Y, Zuo L, Chen JH et al (2006) Modified glomerular filtration rate estimating equation for Chinese patients with chronic kidney disease. J Am Soc Nephrol 17(10):2937–2944 | en_US |
dc.relation.references | doi: 10.1681/ASN.2006040368 | en_US |
dc.relation.references | Fleischmann D, Kamaya A (2009) Optimal vascular and parenchymal contrast enhancement: the current state of the art. Radiol Clin North Am 47(1):13–26 | en_US |
dc.relation.references | doi: 10.1016/j.rcl.2008.10.009 | en_US |
dc.relation.references | Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate–pharmacokinetic analysis and experimental porcine model. Radiology 206(2):455–464 | en_US |
dc.relation.references | Cademartiri F, van der Lugt A, Luccichenti G et al (2002) Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr 26(4):598–607 | en_US |
dc.relation.references | doi: 10.1097/00004728-200207000-00022 | en_US |
dc.relation.references | Becker CR, Hong C, Knez A et al (2003) Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 38(11):690–694 | en_US |
dc.relation.references | doi: 10.1097/01.rli.0000084886.44676.e4 | en_US |
dc.relation.references | Cademartiri F, Mollet NR, Lemos PA et al (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187(4):W430–W433 | en_US |
dc.relation.references | doi: 10.2214/AJR.05.1406 | en_US |
dc.relation.references | Cademartiri F, Maffei E, Palumbo AA et al (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18(3):576–583 | en_US |
dc.relation.references | doi: 10.1007/s00330-007-0773-0 | en_US |
dc.relation.references | Cademartiri F, Mollet NR, van der Lugt A et al (2005) Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 236(2):661–665 | en_US |
dc.relation.references | doi: 10.1148/radiol.2362040468 | en_US |
dc.relation.references | Rist C, Nikolaou K, Kirchin MA et al (2006) Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. Invest Radiol 41(5):460–467 | en_US |
dc.relation.references | doi: 10.1097/01.rli.0000208239.34723.5d | en_US |
dc.relation.references | Fleischmann D, Rubin GD, Bankier AA et al (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214(2):363–371 | en_US |
dc.relation.references | Haage P, Schmitz-Rode T, Hübner D et al (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 174(4):1049–1053 | en_US |
dc.relation.references | Tatsugami F, Kanamoto T, Nakai G et al (2010) Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography. Br J Radiol 83(985):35–39 | en_US |
dc.relation.references | doi: 10.1259/bjr/23203690 | en_US |
dc.relation.references | Tatsugami F, Matsuki M, Inada Y et al (2010) Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography. Acad Radiol 17(2):207–211 | en_US |
dc.relation.references | doi: 10.1016/j.acra.2009.09.010 | en_US |
dc.relation.references | Mitsumori LM, Wang E, May JM et al (2010) Triphasic contrast bolus for whole-chest ECG-gated 64-MDCT of patients with nonspecific chest pain: evaluation of arterial enhancement and streak artifact. AJR Am J Roentgenol 194(3):W263–W271 | en_US |
dc.relation.references | doi: 10.2214/AJR.09.2788 | en_US |
dc.relation.references | Litmanovich D, Zamboni GA, Hauser TH et al (2008) ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain. Eur Radiol 18(2):308–317 | en_US |
dc.relation.references | doi: 10.1007/s00330-007-0739-2 | en_US |
dc.relation.references | Ishida M, Sakuma H, Murashima S et al (2009) Absolute blood contrast concentration and blood signal saturation on myocardial perfusion MRI: estimation from CT data. J Magn Reson Imag 29(1):205–210 | en_US |
dc.relation.references | doi: 10.1002/jmri.21470 | en_US |
dc.relation.references | Webb JA, Thomsen HS, Morcos SK (2005) Members of Contrast Media Safety Committee of European Society of Urogenital Radiology (ESUR). The use of iodinated and gadolinium contrast media during pregnancy and lactation. Eur Radiol 15(6):1234–1240 | en_US |
dc.relation.references | doi: 10.1007/s00330-004-2583-y | en_US |
dc.relation.references | Sakuma H, Ichikawa Y, Chino S et al (2006) Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. J Am Coll Cardiol 48(10):1946–1950 | en_US |
dc.relation.references | doi: 10.1016/j.jacc.2006.07.055 | en_US |
dc.relation.references | Yamaguchi K, Katayama H, Takashima T et al (1991) Prediction of severe adverse reactions to ionic and nonionic contrast media in Japan: evaluation of pretesting. A report from the Japanese Committee on the Safety of Contrast Media. Radiology 178(2):363–367 | en_US |
dc.relation.references | Laroche D, Aimone-Gastin I, Dubois F et al (1998) Mechanisms of severe, immediate reactions to iodinated contrast material. Radiology 209(1):183–190 | en_US |
dc.relation.references | Hopper KD, Houts PS, TenHave TR et al (1994) The effect of informed consent on the level of anxiety in patients given i.v. contrast material. AJR Am J Roentgenol 162(3):531–535 | en_US |
dc.relation.references | Federle MP, Chang PJ, Confer S et al (1998) Frequency and effects of ionic and nonionic CT contrast media during rapid bolus injection. Radiology 206(3):637–640 | en_US |
dc.relation.references | Jacobs JE, Birnbaum BA, Langlotz CP (1998) Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology 209(2):411–416 | en_US |
dc.relation.references | Wang CL, Cohan RH, Ellis JH et al (2007) Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69, 657 intravenous injections. Radiology 243(1):80–87 | en_US |
dc.relation.references | doi: 10.1148/radiol.2431060554 | en_US |
dc.relation.references | Caro JJ, Trindade E, McGregor M (1991) The risks of death and of severe nonfatal reactions with high- vs low-osmolality contrast media: a meta-analysis. AJR Am J Roentgenol 156(4):825–832 | en_US |
dc.relation.references | Bush WH, Swanson DP (1991) Acute reactions to intravascular contrast media: types, risk factors, recognition, and specific treatment. AJR Am J Roentgenol 157(6):1153–1161 | en_US |
dc.relation.references | Dillman JR, Strouse PJ, Ellis JH et al (2007) Incidence and severity of acute allergic-like reactions to i.v nonionic iodinated contrast material in children. AJR Am J Roentgenol 188(6):1643–1647 | en_US |
dc.relation.references | doi: 10.2214/AJR.06.1328 | en_US |
dc.relation.references | Katayama H, Yamaguchi K, Kozuka T et al (1990) Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media. Radiology 175(3):621–628 | en_US |
dc.relation.references | Cochran ST, Bomyea K, Sayre JW (2001) Trends in adverse events after IV administration of contrast media. AJR Am J Roentgenol 176(6):1385–1388 | en_US |
dc.relation.references | Wang CL, Cohan RH, Ellis JH et al (2008) Frequency, outcome, and appropriateness of treatment of nonionic iodinated contrast media reactions. AJR Am J Roentgenol 191(2):409–415 | en_US |
dc.relation.references | doi: 10.2214/AJR.07.3421 | en_US |
dc.relation.references | Nelson KL, Gifford LM, Lauber-Huber C et al (1995) Clinical safety of gadopentetate dimeglumine. Radiology 196(2):439–443 | en_US |
dc.relation.references | Herborn CU, Honold E, Wolf M et al (2007) Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA). Invest Radiol 42(1):58–62 | en_US |
dc.relation.references | doi: 10.1097/01.rli.0000248893.01067.e5 | en_US |
dc.relation.references | Bleicher AG, Kanal E (2008) Assessment of adverse reaction rates to a newly approved MRI contrast agent: review of 23,553 administrations of gadobenate dimeglumine. Am J Roentgenol 191(6):W307–W311 | en_US |
dc.relation.references | doi: 10.2214/AJR.07.3951 | en_US |
dc.relation.references | Christiansen C, Pichler WJ, Skotland T (2000) Delayed allergy-like reactions to X-ray contrast media: mechanistic considerations. Eur Radiol 10(12):1965–1975 | en_US |
dc.relation.references | doi: 10.1007/s003300000543 | en_US |
dc.relation.references | Berkseth RO, Kjellstrand CM (1984) Radiologic contrast-induced nephropathy. Med Clin North Am 68(2):351–370 | en_US |
dc.relation.references | Cruz C, Hricak H, Samhouri F et al (1986) Contrast media for angiography: effect on renal function. Radiology 158(1):109–112 | en_US |
dc.relation.references | Cockcroft DW, Gault MH (1976) Prediction of creatinine clearance from serum creatinine. Nephron 16(1):31–41 | en_US |
dc.relation.references | doi: 10.1159/000180580 | en_US |
dc.relation.references | Hafez T (2007) Modification of diet in renal disease (MDRD) estimated glomerular filtration rate (eGFR) formula. Am J Cardiol 99(4):584 | en_US |
dc.relation.references | doi: 10.1016/j.amjcard.2006.10.013 | en_US |
dc.relation.references | Solomon R, Werner C, Mann D et al (1994) Effects of saline, mannitol, and furosemide to prevent acute decreases in renal function induced by radiocontrast agents. N Engl J Med 331(21):1416–1420 | en_US |
dc.relation.references | doi: 10.1056/NEJM199411243312104 | en_US |
dc.relation.references | Solomon RJ, Natarajan MK, Doucet S et al (2007) Cardiac angiography in renally impaired patients (CARE) study: a randomized double-blind trial of contrast-induced nephropathy in patients with chronic kidney disease. Circulation 115(25):3189–3196 | en_US |
dc.relation.references | doi: 10.1161/CIRCULATIONAHA.106.671644 | en_US |
dc.relation.references | Baker CS, Wragg A, Kumar S et al (2003) A rapid protocol for the prevention of contrast-induced renal dysfunction: the RAPPID study. J Am Coll Cardiol 41(12):2114–2118 | en_US |
dc.relation.references | doi: 10.1016/S0735-1097(03)00487-X | en_US |
dc.relation.references | Ferrario F, Barone MT, Landoni G et al (2009) Acetylcysteine and non-ionic isosmolar contrast-induced nephropathy–a randomized controlled study. Nephrol Dial Transpl 24(10):3103–3107 | en_US |
dc.relation.references | doi: 10.1093/ndt/gfp306 | en_US |
dc.relation.references | Kanter MZ (2006) Comparison of oral and i.v. acetylcysteine in the treatment of acetaminophen poisoning. Am J Health Syst Pharm 63(19):1821–1827 | en_US |
dc.relation.references | doi: 10.2146/ajhp060050 | en_US |
dc.relation.references | Schweiger MJ, Chambers CE, Davidson CJ et al (2007) Prevention of contrast induced nephropathy: recommendations for the high risk patient undergoing cardiovascular procedures. Catheter Cardiovasc Interv 69(1):135–140 | en_US |
dc.relation.references | doi: 10.1002/ccd.20964 | en_US |
dc.relation.references | Younathan CM, Kaude JV, Cook MD et al (1994) Dialysis is not indicated immediately after administration of nonionic contrast agents in patients with end-stage renal disease treated with maintenance dialysis. AJR Am J Roentgenol 163(4):969–971 | en_US |
dc.relation.references | Manufactuer’s Briefing Documents for FDA AdCom Meeting Dec (2009) http://www.fda.gov/downloads/AdvisoryCommittees/CommitteesMeetingMaterials/Drugs/AnestheticAndLifeSupportDrugsAdvisoryCommittee/UCM183205.pdf | en_US |
dc.relation.references | Grobner T (2006) Gadolinium—a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? Nephrol Dial Transpl 21(4):1104–1108 | en_US |
dc.relation.references | doi: 10.1093/ndt/gfk062 | en_US |
dc.relation.references | Perazella MA (2009) Current status of gadolinium toxicity in patients with kidney disease. Clin J Am Soc Nephrol 4(2):461–469 | en_US |
dc.relation.references | doi: 10.2215/CJN.06011108 | en_US |
dc.relation.references | Marckmann P, Skov L, Rossen K et al (2006) Nephrogenic systemic fibrosis: suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging. J Am Soc Nephrol 17(9):2359–2362 | en_US |
dc.relation.references | doi: 10.1681/ASN.2006060601 | en_US |
dc.relation.references | Prince MR, Zhang H, Morris M et al (2008) Incidence of nephrogenic systemic fibrosis at two large medical centers. Radiology 248(3):807–816 | en_US |
dc.relation.references | doi: 10.1148/radiol.2483071863 | en_US |
dc.relation.references | Lu JG, Lv B, Chen XB et al. (2009) What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol [Epub ahead of print] | en_US |
dc.relation.references | Lee VS (2006) Cardiovascular MR imaging: physical principles to practical protocols. In: Lee VS (ed) Tissue characteristics and contrast agents: PD, T1 and T2, 1st edn. Lippincott Williams & Wilkins, Philadelphia, pp 42–50 | en_US |
dc.identifier.volume | 26 | en_US |
dc.identifier.spage | 203 | en_US |
dc.identifier.epage | 212 | en_US |
dc.identifier.eissn | 1573-0743 | en_US |
dc.identifier.isi | WOS:000284955200003 | - |
dc.description.other | Springer Open Choice, 21 Feb 2012 | en_US |
dc.identifier.citeulike | 7973997 | - |