Article: The Finapres 2300e finger cuff. The influence of cuff application on the accuracy of blood pressure measurement
Title | The Finapres 2300e finger cuff. The influence of cuff application on the accuracy of blood pressure measurement |
---|---|
Authors | |
Keywords | Blood pressure blood pressure Equipment Finapres 2300e measurement |
Issue Date | 1993 |
Publisher | Wiley-Blackwell Publishing Ltd. The Journal's web site is located at http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 |
Citation | Anaesthesia, 1993, v. 48 n. 7, p. 611-615 How to Cite? |
Abstract | Blood pressure measurements associated with malapplication of a finger cuff were compared with contemporaneous intra-arterial pressure data in seven volunteers to determine the influence of cuff application on the accuracy of the Finapres 2300e. Systolic readings in all cuff positions differed from arterial line data by more than the recommended standard and tight and loose cuff applications under and over-read respectively, in all subjects. The results show the Finapres to be sensitive to small degrees of finger cuff malapplication which contribute to the bias on direct arterial comparison and limit the reliability of the instrument in clinical practice. |
Persistent Identifier | http://hdl.handle.net/10722/147164 |
ISSN | 2023 Impact Factor: 7.5 2023 SCImago Journal Rankings: 2.400 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jones, RDM | en_US |
dc.contributor.author | Kornberg, JP | en_US |
dc.contributor.author | Roulson, CJ | en_US |
dc.contributor.author | Visram, AR | en_US |
dc.contributor.author | Irwin, MG | en_US |
dc.date.accessioned | 2012-05-29T06:00:30Z | - |
dc.date.available | 2012-05-29T06:00:30Z | - |
dc.date.issued | 1993 | en_US |
dc.identifier.citation | Anaesthesia, 1993, v. 48 n. 7, p. 611-615 | en_US |
dc.identifier.issn | 0003-2409 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/147164 | - |
dc.description.abstract | Blood pressure measurements associated with malapplication of a finger cuff were compared with contemporaneous intra-arterial pressure data in seven volunteers to determine the influence of cuff application on the accuracy of the Finapres 2300e. Systolic readings in all cuff positions differed from arterial line data by more than the recommended standard and tight and loose cuff applications under and over-read respectively, in all subjects. The results show the Finapres to be sensitive to small degrees of finger cuff malapplication which contribute to the bias on direct arterial comparison and limit the reliability of the instrument in clinical practice. | en_US |
dc.language | eng | en_US |
dc.publisher | Wiley-Blackwell Publishing Ltd. The Journal's web site is located at http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 | en_US |
dc.relation.ispartof | Anaesthesia | en_US |
dc.subject | Blood pressure | - |
dc.subject | blood pressure | - |
dc.subject | Equipment | - |
dc.subject | Finapres 2300e | - |
dc.subject | measurement | - |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Blood Pressure | en_US |
dc.subject.mesh | Blood Pressure Determination - Methods | en_US |
dc.subject.mesh | Blood Pressure Monitors - Standards | en_US |
dc.subject.mesh | Fingers | en_US |
dc.subject.mesh | Humans | en_US |
dc.title | The Finapres 2300e finger cuff. The influence of cuff application on the accuracy of blood pressure measurement | en_US |
dc.type | Article | en_US |
dc.identifier.email | Irwin, MG:mgirwin@hku.hk | en_US |
dc.identifier.authority | Irwin, MG=rp00390 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1111/j.1365-2044.1993.tb07129.x | - |
dc.identifier.pmid | 8346779 | - |
dc.identifier.scopus | eid_2-s2.0-0027169495 | en_US |
dc.identifier.volume | 48 | en_US |
dc.identifier.issue | 7 | en_US |
dc.identifier.spage | 611 | en_US |
dc.identifier.epage | 615 | en_US |
dc.identifier.isi | WOS:A1993LK87700015 | - |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.issnl | 0003-2409 | - |