File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Intracytoplasmic barium salts in pleural fluid

TitleIntracytoplasmic barium salts in pleural fluid
Authors
KeywordsBarium crystals
Contamination
Cytology
Energy dispersive spectroscopy system
Pleural fluid
X-ray analysis
Issue Date1993
PublisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/00313025.asp
Citation
Pathology, 1993, v. 25 n. 4, p. 410-411 How to Cite?
AbstractCytological examination of the pleural effusion fluid obtained from a 66-yr-old Chinese lady showed numerous intra- and extracytoplasmic colourless refractile non-birefringent crystals. X-ray analysis of the crystals identified barium salts. On further inquiry, it was learnt that the fluid obtained had been placed in a specimen bottle provided by the x-ray department. This container was presumably contaminated with barium salts. The case highlights an unusual aspect of specimen contamination and the usefulness of x-ray analysis in the identification of crystals/substances.
Persistent Identifierhttp://hdl.handle.net/10722/147992
ISSN
2021 Impact Factor: 5.335
2020 SCImago Journal Rankings: 1.335
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChan, ACLen_US
dc.contributor.authorCollins, RJen_US
dc.contributor.authorCheung, TKen_US
dc.date.accessioned2012-05-29T06:10:16Z-
dc.date.available2012-05-29T06:10:16Z-
dc.date.issued1993en_US
dc.identifier.citationPathology, 1993, v. 25 n. 4, p. 410-411en_US
dc.identifier.issn0031-3025en_US
dc.identifier.urihttp://hdl.handle.net/10722/147992-
dc.description.abstractCytological examination of the pleural effusion fluid obtained from a 66-yr-old Chinese lady showed numerous intra- and extracytoplasmic colourless refractile non-birefringent crystals. X-ray analysis of the crystals identified barium salts. On further inquiry, it was learnt that the fluid obtained had been placed in a specimen bottle provided by the x-ray department. This container was presumably contaminated with barium salts. The case highlights an unusual aspect of specimen contamination and the usefulness of x-ray analysis in the identification of crystals/substances.en_US
dc.languageengen_US
dc.publisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/00313025.aspen_US
dc.relation.ispartofPathologyen_US
dc.subjectBarium crystals-
dc.subjectContamination-
dc.subjectCytology-
dc.subjectEnergy dispersive spectroscopy system-
dc.subjectPleural fluid-
dc.subjectX-ray analysis-
dc.subject.meshAgeden_US
dc.subject.meshBarium Compounds - Analysisen_US
dc.subject.meshEquipment Contaminationen_US
dc.subject.meshFemaleen_US
dc.subject.meshHumansen_US
dc.subject.meshPleural Effusion - Chemistryen_US
dc.subject.meshSpectrum Analysisen_US
dc.subject.meshX-Raysen_US
dc.titleIntracytoplasmic barium salts in pleural fluiden_US
dc.typeArticleen_US
dc.identifier.emailCollins, RJ:rcollins@hkucc.hku.hken_US
dc.identifier.authorityCollins, RJ=rp00251en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.3109/00313029309090870-
dc.identifier.pmid8165010-
dc.identifier.scopuseid_2-s2.0-0027724927en_US
dc.identifier.volume25en_US
dc.identifier.issue4en_US
dc.identifier.spage410en_US
dc.identifier.epage411en_US
dc.identifier.isiWOS:A1993NP11400018-
dc.publisher.placeUnited Kingdomen_US
dc.identifier.issnl0031-3025-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats