File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: An integrated microfluidic system for interstitial fluid transdermal extraction

TitleAn integrated microfluidic system for interstitial fluid transdermal extraction
Authors
KeywordsContinuous glucose monitoring
Interstitial fluid transdermal extraction
Micro volume sensor
Microfluidics
Venturi tube
Issue Date2011
Citation
2011 16Th International Solid-State Sensors, Actuators And Microsystems Conference, Transducers'11, 2011, p. 1236-1239 How to Cite?
AbstractWe present a new microfluidic system for transdermal interstitial fluid (ISF) extraction, collection, and volumetric measurement towards the application of continuous glucose monitoring. This device consists of a venturi tube, a volume sensor, pneumatic valves, and microchannels. Under the management of pneumatic valves, demonstration of the defined volume normal saline injection, ISF extraction, collection and volumetric measurement functions of the system is presented using the stable vacuum generated by the integrated venturi structure. The stability of defined volume normal saline injection is tested, and the coefficient of variation for 20 tests is 0.0041. A simulating test of ISF collection and volumetric measurement is done with the system, and the measurement results correlate well (R 2=0.9992) with the values measured by micro syringe. © 2011 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/149035
References

 

DC FieldValueLanguage
dc.contributor.authorYu, HXen_HK
dc.contributor.authorLi, DCen_HK
dc.contributor.authorRoberts, RCen_HK
dc.contributor.authorLiang, WSen_HK
dc.contributor.authorXu, KXen_HK
dc.contributor.authorTien, NCen_HK
dc.date.accessioned2012-06-20T06:18:00Z-
dc.date.available2012-06-20T06:18:00Z-
dc.date.issued2011en_HK
dc.identifier.citation2011 16Th International Solid-State Sensors, Actuators And Microsystems Conference, Transducers'11, 2011, p. 1236-1239en_US
dc.identifier.urihttp://hdl.handle.net/10722/149035-
dc.description.abstractWe present a new microfluidic system for transdermal interstitial fluid (ISF) extraction, collection, and volumetric measurement towards the application of continuous glucose monitoring. This device consists of a venturi tube, a volume sensor, pneumatic valves, and microchannels. Under the management of pneumatic valves, demonstration of the defined volume normal saline injection, ISF extraction, collection and volumetric measurement functions of the system is presented using the stable vacuum generated by the integrated venturi structure. The stability of defined volume normal saline injection is tested, and the coefficient of variation for 20 tests is 0.0041. A simulating test of ISF collection and volumetric measurement is done with the system, and the measurement results correlate well (R 2=0.9992) with the values measured by micro syringe. © 2011 IEEE.en_HK
dc.languageengen_US
dc.relation.ispartof2011 16th International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS'11en_HK
dc.subjectContinuous glucose monitoringen_HK
dc.subjectInterstitial fluid transdermal extractionen_HK
dc.subjectMicro volume sensoren_HK
dc.subjectMicrofluidicsen_HK
dc.subjectVenturi tubeen_HK
dc.titleAn integrated microfluidic system for interstitial fluid transdermal extractionen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailRoberts, RC: rcr8@hku.hken_HK
dc.identifier.emailTien, NC: nctien@hku.hken_HK
dc.identifier.authorityRoberts, RC=rp01738en_HK
dc.identifier.authorityTien, NC=rp01604en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/TRANSDUCERS.2011.5969387en_HK
dc.identifier.scopuseid_2-s2.0-80052131761en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-80052131761&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.spage1236en_HK
dc.identifier.epage1239en_HK
dc.identifier.scopusauthoridYu, HX=16240359300en_HK
dc.identifier.scopusauthoridLi, DC=48761554400en_HK
dc.identifier.scopusauthoridRoberts, RC=24466830100en_HK
dc.identifier.scopusauthoridLiang, WS=50161762500en_HK
dc.identifier.scopusauthoridXu, KX=7403282051en_HK
dc.identifier.scopusauthoridTien, NC=7006532826en_HK

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats