Article: Comparison of horizontal earthquake action in the seismic design codes of China, America and Europe
Title | Comparison of horizontal earthquake action in the seismic design codes of China, America and Europe |
---|---|
Authors | |
Keywords | Comparison Horizontal Earthquake Action Importance Seismic Design Strength Reduction Factors |
Issue Date | 2010 |
Citation | World Information On Earthquake Engineering, 2010, v. 26 n. 1, p. 167-172 How to Cite? |
Abstract | The differences of horizontal earthquake action in the seismic design codes of China, America and Europe are studied in this paper. Firstly, comparison of building importance, strength reduction factors of GB50011-2001, FEMA450 and Eurocode 8 is presented, and base shear method of GB50011 -2001, equivalent lateral force procedure of FEMA450, lateral force analysis method of Eurocode 8 are summarized. Then, the seismic base shear of a multistorey frame structure with different ductility is computed as an office or a hospital building under intensities 7, 8 and 9, the both computed results are compared, and some differences of seismic base shear are found for the three codes. |
Persistent Identifier | http://hdl.handle.net/10722/150531 |
ISSN | 2023 SCImago Journal Rankings: 0.249 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lu, H | en_US |
dc.contributor.author | Liang, P | en_US |
dc.contributor.author | Yang, J | en_US |
dc.contributor.author | Qiu, Z | en_US |
dc.date.accessioned | 2012-06-26T06:05:30Z | - |
dc.date.available | 2012-06-26T06:05:30Z | - |
dc.date.issued | 2010 | en_US |
dc.identifier.citation | World Information On Earthquake Engineering, 2010, v. 26 n. 1, p. 167-172 | en_US |
dc.identifier.issn | 1007-6069 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/150531 | - |
dc.description.abstract | The differences of horizontal earthquake action in the seismic design codes of China, America and Europe are studied in this paper. Firstly, comparison of building importance, strength reduction factors of GB50011-2001, FEMA450 and Eurocode 8 is presented, and base shear method of GB50011 -2001, equivalent lateral force procedure of FEMA450, lateral force analysis method of Eurocode 8 are summarized. Then, the seismic base shear of a multistorey frame structure with different ductility is computed as an office or a hospital building under intensities 7, 8 and 9, the both computed results are compared, and some differences of seismic base shear are found for the three codes. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | World Information on Earthquake Engineering | en_US |
dc.subject | Comparison | en_US |
dc.subject | Horizontal Earthquake Action | en_US |
dc.subject | Importance | en_US |
dc.subject | Seismic Design | en_US |
dc.subject | Strength Reduction Factors | en_US |
dc.title | Comparison of horizontal earthquake action in the seismic design codes of China, America and Europe | en_US |
dc.type | Article | en_US |
dc.identifier.email | Yang, J:junyang@hkucc.hku.hk | en_US |
dc.identifier.authority | Yang, J=rp00201 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.scopus | eid_2-s2.0-77954451465 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-77954451465&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 26 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.spage | 167 | en_US |
dc.identifier.epage | 172 | en_US |
dc.publisher.place | China | en_US |
dc.identifier.scopusauthorid | Lu, H=26323246700 | en_US |
dc.identifier.scopusauthorid | Liang, P=36162559900 | en_US |
dc.identifier.scopusauthorid | Yang, J=35605258800 | en_US |
dc.identifier.scopusauthorid | Qiu, Z=36191057500 | en_US |
dc.identifier.issnl | 1007-6069 | - |