Article: Improvement of the equivalent dose determination using aliquots of potassium feldspar

TitleImprovement of the equivalent dose determination using aliquots of potassium feldspar
Authors
Issue Date2001
PublisherPergamon. The Journal's web site is located at http://www.elsevier.com/locate/radmeas
Citation
Radiation Measurements, 2001, v. 33 n. 1, p. 65-71 How to Cite?
AbstractA procedure of preheat/measurement, dose/preheat/measurement and preheat/measurement is proposed, in which all the measurements for the equivalent dose determination are made on a single aliquot of K-feldspar sample with the additive-dose method. Correction for the loss of IRSL signal due to preheat/measurement cycles is made using correction factors determined both at the beginning and the end of the measurement cycle. It is suggested that the optimal preheat condition for the sample can be determined by comparing the correction factors obtained from the two stages of analysis, as a function of preheat temperature. The most appropriate preheat for our K-feldspar sample is at 235°C for 10 min. © 2001 Elsevier Science Ltd.
Persistent Identifierhttp://hdl.handle.net/10722/151046
ISSN
2021 Impact Factor: 1.743
2020 SCImago Journal Rankings: 0.703
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorZhang, JFen_US
dc.contributor.authorLi, SHen_US
dc.contributor.authorTso, MYWen_US
dc.date.accessioned2012-06-26T06:16:28Z-
dc.date.available2012-06-26T06:16:28Z-
dc.date.issued2001en_US
dc.identifier.citationRadiation Measurements, 2001, v. 33 n. 1, p. 65-71en_US
dc.identifier.issn1350-4487en_US
dc.identifier.urihttp://hdl.handle.net/10722/151046-
dc.description.abstractA procedure of preheat/measurement, dose/preheat/measurement and preheat/measurement is proposed, in which all the measurements for the equivalent dose determination are made on a single aliquot of K-feldspar sample with the additive-dose method. Correction for the loss of IRSL signal due to preheat/measurement cycles is made using correction factors determined both at the beginning and the end of the measurement cycle. It is suggested that the optimal preheat condition for the sample can be determined by comparing the correction factors obtained from the two stages of analysis, as a function of preheat temperature. The most appropriate preheat for our K-feldspar sample is at 235°C for 10 min. © 2001 Elsevier Science Ltd.en_US
dc.languageengen_US
dc.publisherPergamon. The Journal's web site is located at http://www.elsevier.com/locate/radmeasen_US
dc.relation.ispartofRadiation Measurementsen_US
dc.titleImprovement of the equivalent dose determination using aliquots of potassium feldsparen_US
dc.typeArticleen_US
dc.identifier.emailLi, SH:shli@hku.hken_US
dc.identifier.authorityLi, SH=rp00740en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/S1350-4487(00)00132-3en_US
dc.identifier.scopuseid_2-s2.0-0034744547en_US
dc.identifier.hkuros63410-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034744547&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume33en_US
dc.identifier.issue1en_US
dc.identifier.spage65en_US
dc.identifier.epage71en_US
dc.identifier.isiWOS:000166370100007-
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridZhang, JF=7601338769en_US
dc.identifier.scopusauthoridLi, SH=24438103700en_US
dc.identifier.scopusauthoridTso, MYW=7102052118en_US
dc.identifier.issnl1350-4487-

Export via OAI-PMH Interface in XML Formats


OR