File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Effect of protraction headgear on Class III malocclusion.

TitleEffect of protraction headgear on Class III malocclusion.
Authors
Issue Date1992
PublisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.com
Citation
Quintessence International, 1992, v. 23 n. 3, p. 197-207 How to Cite?
AbstractTen patients with skeletal Class III malocclusion in the early mixed dentition who were treated with maxillary expansion appliance and protraction headgear were compared with reasonably matched controls. Significant orthopedic effects were found after as little as 6 months of treatment. Cephalometric analysis revealed that the correction of Class III malocclusion was primarily a result of forward and downward movement of the maxilla and backward rotation of the mandible. The clinical result of one patient treated with this appliance is used to demonstrate the importance of force magnitudes and directions, as well as the design of the appliance, to the success of the treatment.
Persistent Identifierhttp://hdl.handle.net/10722/153787
ISSN
2023 Impact Factor: 1.3
2023 SCImago Journal Rankings: 0.487

 

DC FieldValueLanguage
dc.contributor.authorNgan, Pen_US
dc.contributor.authorWei, SHen_US
dc.contributor.authorHagg, Uen_US
dc.contributor.authorYiu, CKen_US
dc.contributor.authorMerwin, Den_US
dc.contributor.authorStickel, Ben_US
dc.date.accessioned2012-08-08T08:21:34Z-
dc.date.available2012-08-08T08:21:34Z-
dc.date.issued1992en_US
dc.identifier.citationQuintessence International, 1992, v. 23 n. 3, p. 197-207en_US
dc.identifier.issn0033-6572en_US
dc.identifier.urihttp://hdl.handle.net/10722/153787-
dc.description.abstractTen patients with skeletal Class III malocclusion in the early mixed dentition who were treated with maxillary expansion appliance and protraction headgear were compared with reasonably matched controls. Significant orthopedic effects were found after as little as 6 months of treatment. Cephalometric analysis revealed that the correction of Class III malocclusion was primarily a result of forward and downward movement of the maxilla and backward rotation of the mandible. The clinical result of one patient treated with this appliance is used to demonstrate the importance of force magnitudes and directions, as well as the design of the appliance, to the success of the treatment.en_US
dc.languageengen_US
dc.publisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.comen_US
dc.relation.ispartofQuintessence internationalen_US
dc.subject.meshCephalometryen_US
dc.subject.meshChilden_US
dc.subject.meshDentition, Mixeden_US
dc.subject.meshExtraoral Traction Appliancesen_US
dc.subject.meshFemaleen_US
dc.subject.meshHumansen_US
dc.subject.meshMaleen_US
dc.subject.meshMalocclusion, Angle Class Iii - Therapyen_US
dc.subject.meshMaxillofacial Developmenten_US
dc.subject.meshOrthodontic Appliance Designen_US
dc.subject.meshOrthodontics, Corrective - Methodsen_US
dc.subject.meshPalatal Expansion Techniqueen_US
dc.subject.meshProspective Studiesen_US
dc.subject.meshReference Valuesen_US
dc.titleEffect of protraction headgear on Class III malocclusion.en_US
dc.typeArticleen_US
dc.identifier.emailHagg, U:euohagg@hkusua.hku.hken_US
dc.identifier.emailYiu, CK:ckyyiu@hkucc.hku.hken_US
dc.identifier.authorityHagg, U=rp00020en_US
dc.identifier.authorityYiu, CK=rp00018en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.pmid1641462-
dc.identifier.scopuseid_2-s2.0-0026827552en_US
dc.identifier.volume23en_US
dc.identifier.issue3en_US
dc.identifier.spage197en_US
dc.identifier.epage207en_US
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridNgan, P=7006250823en_US
dc.identifier.scopusauthoridWei, SH=7401765260en_US
dc.identifier.scopusauthoridHagg, U=7006790279en_US
dc.identifier.scopusauthoridYiu, CK=7007115156en_US
dc.identifier.scopusauthoridMerwin, D=16683389900en_US
dc.identifier.scopusauthoridStickel, B=6506431250en_US
dc.identifier.issnl0033-6572-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats