File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.tripleo.2006.03.011
- Scopus: eid_2-s2.0-33947509981
- PMID: 17395071
- WOS: WOS:000245707400019
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography
Title | The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography |
---|---|
Authors | |
Issue Date | 2007 |
Publisher | Mosby, Inc. The Journal's web site is located at http://www.elsevier.com/locate/tripleo |
Citation | Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology And Endodontology, 2007, v. 103 n. 4, p. 550-559 How to Cite? |
Abstract | Objective: The purpose of this study was to investigate in vitro the accuracy of three-dimensional (3D) magnetic resonance imaging (MRI) to measure the mandible. Study design: The optimal MRI sequence for 3D mandible from the data of 2 volunteers was determined to be 3D vibe. MRI and computed tomography (CT) scans of tube, mandible, and hemimandible phantoms were obtained. MRI with 3D vibe and standard parameters used in clinical practice for 3D reconstructions of jawbones on CT were used. Pearson's correlation coefficient, standard deviation (SD), and accuracy in measurement on reconstructed 3D MRI and CT were compared to direct osteometric measurement of the phantoms. Results: The correlation coefficient between MRI and direct osteometry was high, with r = 0.85 to 0.99 (P < .001). The difference ranged from -1.5 to 0.7 mm (-8.9%-11.1%) on smaller distances, which is important for orthognathic surgery. The accuracy of MRI was similar to that of CT. Conclusion: 3D vibe MRI provided adequate dimensional accuracy and image quality during in vitro examination of the mandible. © 2007 Mosby, Inc. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/154451 |
ISSN | 2011 Impact Factor: 1.457 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Goto, TK | en_US |
dc.contributor.author | Nishida, S | en_US |
dc.contributor.author | Nakamura, Y | en_US |
dc.contributor.author | Tokumori, K | en_US |
dc.contributor.author | Nakamura, Y | en_US |
dc.contributor.author | Kobayashi, K | en_US |
dc.contributor.author | Yoshida, Y | en_US |
dc.contributor.author | Yoshiura, K | en_US |
dc.date.accessioned | 2012-08-08T08:25:24Z | - |
dc.date.available | 2012-08-08T08:25:24Z | - |
dc.date.issued | 2007 | en_US |
dc.identifier.citation | Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology And Endodontology, 2007, v. 103 n. 4, p. 550-559 | en_US |
dc.identifier.issn | 1079-2104 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/154451 | - |
dc.description.abstract | Objective: The purpose of this study was to investigate in vitro the accuracy of three-dimensional (3D) magnetic resonance imaging (MRI) to measure the mandible. Study design: The optimal MRI sequence for 3D mandible from the data of 2 volunteers was determined to be 3D vibe. MRI and computed tomography (CT) scans of tube, mandible, and hemimandible phantoms were obtained. MRI with 3D vibe and standard parameters used in clinical practice for 3D reconstructions of jawbones on CT were used. Pearson's correlation coefficient, standard deviation (SD), and accuracy in measurement on reconstructed 3D MRI and CT were compared to direct osteometric measurement of the phantoms. Results: The correlation coefficient between MRI and direct osteometry was high, with r = 0.85 to 0.99 (P < .001). The difference ranged from -1.5 to 0.7 mm (-8.9%-11.1%) on smaller distances, which is important for orthognathic surgery. The accuracy of MRI was similar to that of CT. Conclusion: 3D vibe MRI provided adequate dimensional accuracy and image quality during in vitro examination of the mandible. © 2007 Mosby, Inc. All rights reserved. | en_US |
dc.language | eng | en_US |
dc.publisher | Mosby, Inc. The Journal's web site is located at http://www.elsevier.com/locate/tripleo | en_US |
dc.relation.ispartof | Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology | en_US |
dc.subject.mesh | Cephalometry - Methods | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Imaging, Three-Dimensional - Methods | en_US |
dc.subject.mesh | Magnetic Resonance Imaging | en_US |
dc.subject.mesh | Mandible - Anatomy & Histology | en_US |
dc.subject.mesh | Observer Variation | en_US |
dc.subject.mesh | Phantoms, Imaging | en_US |
dc.subject.mesh | Statistics, Nonparametric | en_US |
dc.subject.mesh | Tomography, X-Ray Computed | en_US |
dc.title | The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography | en_US |
dc.type | Article | en_US |
dc.identifier.email | Goto, TK:gototk@hku.hk | en_US |
dc.identifier.authority | Goto, TK=rp01434 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1016/j.tripleo.2006.03.011 | en_US |
dc.identifier.pmid | 17395071 | - |
dc.identifier.scopus | eid_2-s2.0-33947509981 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-33947509981&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 103 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.spage | 550 | en_US |
dc.identifier.epage | 559 | en_US |
dc.identifier.isi | WOS:000245707400019 | - |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Goto, TK=7403938313 | en_US |
dc.identifier.scopusauthorid | Nishida, S=7402252582 | en_US |
dc.identifier.scopusauthorid | Nakamura, Y=36106137700 | en_US |
dc.identifier.scopusauthorid | Tokumori, K=6603353660 | en_US |
dc.identifier.scopusauthorid | Nakamura, Y=7406387857 | en_US |
dc.identifier.scopusauthorid | Kobayashi, K=24076495200 | en_US |
dc.identifier.scopusauthorid | Yoshida, Y=35398664300 | en_US |
dc.identifier.scopusauthorid | Yoshiura, K=7006527913 | en_US |
dc.identifier.issnl | 1079-2104 | - |