File Download
Supplementary

Conference Paper: An animal study comparing electrocautery and nanopeptide scaffold in neurosurgical haemostasis

TitleAn animal study comparing electrocautery and nanopeptide scaffold in neurosurgical haemostasis
Authors
Issue Date2011
PublisherEANS 2011.
Citation
The 14th European Congress of Neurosurgery (EANS 2011), Rome, Italy, 9-14 October 2011. How to Cite?
AbstractINTRODUCTION: Bipolar electrocautery is commonly used in neurosurgery but it may also cause additional tissue injury. A search for novel biomaterials that are conducive to haemostasis and healing is needed. RADA16-I, a type I self-assembling peptide nanofibre scaffold (SAPNS), is a novel biomaterial and a potential alternative haemostatic agent for clinical use. OBJECTIVE: To investigate the haemostatic property of RADA16-I, and to compare it with bipolar electrocautery. MATERIALS AND METHODS: Adult female Sprague Dawley (SD) rats (220g – 250g) were craniotomized and a cortical vessel was transected. Animals were randomized to receive (i) bipolar electrocautery; (ii) RADA16-1 for haemostasis. A third group received electrocoagulated lesions bilaterally, with RADA16-I added on the left. The extent of tissue necrosis, cellular infiltration, and adjacent neuronal degeneration were studied. RESULTS: RADA16-I achieved haemostasis instantaneously. Its use resulted in significantly less tissue necrosis when compared with electrocautery on magnetic resonance imaging studies and histological examinations. It was also associated with less astrocyte and macrophage infiltration in the surrounding brain. CONCLUSION: RADA16-I achieves neurosurgical haemostasis effectively and its use is associated with less tissue damage when compared with bipolar electrocautery. Whether this would translate into better preservation of function and/or better recovery of deficit requires further analysis using another injury model on eloquent cortex and functional outcome analysis. This pilot study demonstrates that a nanopeptide-based biomaterial may be exploited as a potential alternative to electrocautery for clinical use.
Persistent Identifierhttp://hdl.handle.net/10722/160436

 

DC FieldValueLanguage
dc.contributor.authorLeung, GKKen_US
dc.contributor.authorWang, Yen_US
dc.contributor.authorUn, Ten_US
dc.contributor.authorWu, Wen_US
dc.date.accessioned2012-08-16T06:11:09Z-
dc.date.available2012-08-16T06:11:09Z-
dc.date.issued2011en_US
dc.identifier.citationThe 14th European Congress of Neurosurgery (EANS 2011), Rome, Italy, 9-14 October 2011.en_US
dc.identifier.urihttp://hdl.handle.net/10722/160436-
dc.description.abstractINTRODUCTION: Bipolar electrocautery is commonly used in neurosurgery but it may also cause additional tissue injury. A search for novel biomaterials that are conducive to haemostasis and healing is needed. RADA16-I, a type I self-assembling peptide nanofibre scaffold (SAPNS), is a novel biomaterial and a potential alternative haemostatic agent for clinical use. OBJECTIVE: To investigate the haemostatic property of RADA16-I, and to compare it with bipolar electrocautery. MATERIALS AND METHODS: Adult female Sprague Dawley (SD) rats (220g – 250g) were craniotomized and a cortical vessel was transected. Animals were randomized to receive (i) bipolar electrocautery; (ii) RADA16-1 for haemostasis. A third group received electrocoagulated lesions bilaterally, with RADA16-I added on the left. The extent of tissue necrosis, cellular infiltration, and adjacent neuronal degeneration were studied. RESULTS: RADA16-I achieved haemostasis instantaneously. Its use resulted in significantly less tissue necrosis when compared with electrocautery on magnetic resonance imaging studies and histological examinations. It was also associated with less astrocyte and macrophage infiltration in the surrounding brain. CONCLUSION: RADA16-I achieves neurosurgical haemostasis effectively and its use is associated with less tissue damage when compared with bipolar electrocautery. Whether this would translate into better preservation of function and/or better recovery of deficit requires further analysis using another injury model on eloquent cortex and functional outcome analysis. This pilot study demonstrates that a nanopeptide-based biomaterial may be exploited as a potential alternative to electrocautery for clinical use.-
dc.languageengen_US
dc.publisherEANS 2011.-
dc.relation.ispartof14th European Congress of Neurosurgery, EANS 2011en_US
dc.titleAn animal study comparing electrocautery and nanopeptide scaffold in neurosurgical haemostasisen_US
dc.typeConference_Paperen_US
dc.identifier.emailLeung, GKK: gilberto@hku.hken_US
dc.identifier.emailWang, Y: monkeyme@hku.hken_US
dc.identifier.authorityLeung, GKK=rp00522en_US
dc.description.naturelink_to_OA_fulltext-
dc.identifier.hkuros204799en_US
dc.publisher.placeItaly-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats