File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1093/eurheartj/sum057
- Scopus: eid_2-s2.0-77949357393
- WOS: WOS:000252061700003
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Evolution of pacing for bradycardias: Sensors
Title | Evolution of pacing for bradycardias: Sensors |
---|---|
Authors | |
Keywords | Chronotropic Incompetence Exercise Pacing Rate-Adaptive Pacing Sensor Sinus Node Disease |
Issue Date | 2007 |
Citation | European Heart Journal, Supplement, 2007, v. 9 I, p. I11-I22 How to Cite? |
Abstract | A physiological pacing system should be able to restore normal chronotropic response and optimal conduction within and between the atrial and ventricular pacing. Implantable sensors are initially developed to overcome chronotropic incompetence of the sinus node to exercise and non-exercise requirements. Ideal sensor behaviour includes speed of response, proportionality, specificity, and sensitivity. Sensors can be classified by the method they detect a physiological change: body accelerations, paced QRS, impedance and sensors that require special leads. Rate-adaptive pacing is proven to improve exercise capacity and oxygen consumption over fixed-rated pacing, especially during ventricular pacing. Patients with chronotropic incompetence can derive symptomatic benefit in the rate-adaptive mode. The latest development involves the use of sensors to monitor heart failure, and to best optimize rate and conduction status in cardiac resynchronization therapy. © The Author 2007. |
Persistent Identifier | http://hdl.handle.net/10722/163297 |
ISSN | 2023 Impact Factor: 1.7 2023 SCImago Journal Rankings: 0.477 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lau, CP | en_US |
dc.contributor.author | Tse, HF | en_US |
dc.contributor.author | Camm, AJ | en_US |
dc.contributor.author | Barold, SS | en_US |
dc.date.accessioned | 2012-09-05T05:29:49Z | - |
dc.date.available | 2012-09-05T05:29:49Z | - |
dc.date.issued | 2007 | en_US |
dc.identifier.citation | European Heart Journal, Supplement, 2007, v. 9 I, p. I11-I22 | en_US |
dc.identifier.issn | 1520-765X | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/163297 | - |
dc.description.abstract | A physiological pacing system should be able to restore normal chronotropic response and optimal conduction within and between the atrial and ventricular pacing. Implantable sensors are initially developed to overcome chronotropic incompetence of the sinus node to exercise and non-exercise requirements. Ideal sensor behaviour includes speed of response, proportionality, specificity, and sensitivity. Sensors can be classified by the method they detect a physiological change: body accelerations, paced QRS, impedance and sensors that require special leads. Rate-adaptive pacing is proven to improve exercise capacity and oxygen consumption over fixed-rated pacing, especially during ventricular pacing. Patients with chronotropic incompetence can derive symptomatic benefit in the rate-adaptive mode. The latest development involves the use of sensors to monitor heart failure, and to best optimize rate and conduction status in cardiac resynchronization therapy. © The Author 2007. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | European Heart Journal, Supplement | en_US |
dc.subject | Chronotropic Incompetence | en_US |
dc.subject | Exercise | en_US |
dc.subject | Pacing | en_US |
dc.subject | Rate-Adaptive Pacing | en_US |
dc.subject | Sensor | en_US |
dc.subject | Sinus Node Disease | en_US |
dc.title | Evolution of pacing for bradycardias: Sensors | en_US |
dc.type | Article | en_US |
dc.identifier.email | Tse, HF:hftse@hkucc.hku.hk | en_US |
dc.identifier.authority | Tse, HF=rp00428 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1093/eurheartj/sum057 | en_US |
dc.identifier.scopus | eid_2-s2.0-77949357393 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-77949357393&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 9 | en_US |
dc.identifier.issue | I | en_US |
dc.identifier.spage | I11 | en_US |
dc.identifier.epage | I22 | en_US |
dc.identifier.isi | WOS:000252061700003 | - |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.scopusauthorid | Lau, CP=7401968501 | en_US |
dc.identifier.scopusauthorid | Tse, HF=7006070805 | en_US |
dc.identifier.scopusauthorid | Camm, AJ=7202602504 | en_US |
dc.identifier.scopusauthorid | Barold, SS=7101800584 | en_US |
dc.identifier.issnl | 1520-765X | - |