File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: NIR-emissive alkynylplatinum(II) terpyridyl complex as a turn-on selective probe for heparin quantification by induced helical self-assembly behaviour

TitleNIR-emissive alkynylplatinum(II) terpyridyl complex as a turn-on selective probe for heparin quantification by induced helical self-assembly behaviour
Authors
Keywordsbiosensors
heparin
noncovalent interactions
platinum
self-assembly
Issue Date2011
PublisherWiley - V C H Verlag GmbH & Co KGaA. The Journal's web site is located at http://www.wiley-vch.de/home/chemistry
Citation
Chemistry - A European Journal, 2011, v. 17 n. 43, p. 11987-11990 How to Cite?
AbstractNIR-emissive heparin sensor: A convenient and selective sensing protocol has been established for the quantification of both unfractionated and low-molecular-weight heparin, based on the heparin-induced helical self-assembly feature of a NIR-emissive alkynylplatinum(II) terpyridyl complex (see scheme), for which the detection range covers the clinical dosage level. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Persistent Identifierhttp://hdl.handle.net/10722/168573
ISSN
2023 Impact Factor: 3.9
2023 SCImago Journal Rankings: 1.058
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorYeung, MCLen_US
dc.contributor.authorYam, VWWen_US
dc.date.accessioned2012-10-08T03:20:54Z-
dc.date.available2012-10-08T03:20:54Z-
dc.date.issued2011en_US
dc.identifier.citationChemistry - A European Journal, 2011, v. 17 n. 43, p. 11987-11990en_US
dc.identifier.issn0947-6539en_US
dc.identifier.urihttp://hdl.handle.net/10722/168573-
dc.description.abstractNIR-emissive heparin sensor: A convenient and selective sensing protocol has been established for the quantification of both unfractionated and low-molecular-weight heparin, based on the heparin-induced helical self-assembly feature of a NIR-emissive alkynylplatinum(II) terpyridyl complex (see scheme), for which the detection range covers the clinical dosage level. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.en_US
dc.languageengen_US
dc.publisherWiley - V C H Verlag GmbH & Co KGaA. The Journal's web site is located at http://www.wiley-vch.de/home/chemistryen_US
dc.relation.ispartofChemistry - A European Journalen_US
dc.subjectbiosensors-
dc.subjectheparin-
dc.subjectnoncovalent interactions-
dc.subjectplatinum-
dc.subjectself-assembly-
dc.subject.meshBiosensing Techniquesen_US
dc.subject.meshHeparin - Chemistryen_US
dc.subject.meshMolecular Structureen_US
dc.subject.meshOrganoplatinum Compounds - Chemistryen_US
dc.subject.meshSpectroscopy, Near-Infrared - Methodsen_US
dc.titleNIR-emissive alkynylplatinum(II) terpyridyl complex as a turn-on selective probe for heparin quantification by induced helical self-assembly behaviouren_US
dc.typeArticleen_US
dc.identifier.emailYam, VWW:wwyam@hku.hken_US
dc.identifier.authorityYam, VWW=rp00822en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1002/chem.201101762en_US
dc.identifier.pmid21915929-
dc.identifier.scopuseid_2-s2.0-80054029292en_US
dc.identifier.hkuros204513-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-80054029292&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume17en_US
dc.identifier.issue43en_US
dc.identifier.spage11987en_US
dc.identifier.epage11990en_US
dc.identifier.isiWOS:000297316100006-
dc.publisher.placeGermanyen_US
dc.identifier.scopusauthoridYeung, MCL=37032452300en_US
dc.identifier.scopusauthoridYam, VWW=18539304700en_US
dc.identifier.issnl0947-6539-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats