File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/0003-2670(92)80216-T
- Scopus: eid_2-s2.0-0026582888
- WOS: WOS:A1992HX85600049
- Find via
Supplementary
- Citations:
- Appears in Collections:
Conference Paper: Application of square-wave voltammetry for the determination of ascorbic acid in soft drinks and fruit juices using a flow-injection system
Title | Application of square-wave voltammetry for the determination of ascorbic acid in soft drinks and fruit juices using a flow-injection system |
---|---|
Authors | |
Keywords | Ascorbic acid Flow system Fruit juices Soft drinks Voltammetry |
Issue Date | 1992 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/aca |
Citation | Analytica Chimica Acta, 1992, v. 261 n. 1-2, p. 375-380 How to Cite? |
Abstract | The application of square-wave voltammetry for detection in the flow-injection determination of ascorbic acid in soft drinks and fruit juices was investigated. The pH of the solution was buffered at 2.87 to stabilize the ascorbic acid prior to analysis. Parameters such as scan rate, square-wave amplitude, step height and flow-rate of electrolyte were found to have little effect on the potential, but a significant effect on the current. The analytical current is only slightly affected by the flow-rate of the electrolyte and a maximum scan rate of 0.5 V s-1 can be used. As a compromise between sensitivity and selectivity, 40 mV was chosen as the amplitude of the square wave and 10 mV as the potential step height. Similarly, a flow-rate of 0.5 ml min-1 and an injection volume of 100 μl were chosen as a compromise between the sensitivity and resolution of the FIA method. Using the above procedures, the maximum number of samples that could be analysed was 120 h-1. The linear calibration range was from 2 x 10-6 to 6 x 10-3 M and the determination limit (10δ) was 2 x 10-7 M. No significant interference was found from additives commonly found in juices and drinks samples within their normal concentration ranges. Four juice samples were analysed using the developed method and the results were compared with those given by the established AOAC method. No significant difference was observed between the two methods used for the four samples studied. |
Persistent Identifier | http://hdl.handle.net/10722/168794 |
ISSN | 2023 Impact Factor: 5.7 2023 SCImago Journal Rankings: 0.998 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fung, YS | en_US |
dc.contributor.author | Mo, SY | en_US |
dc.date.accessioned | 2012-10-08T03:34:17Z | - |
dc.date.available | 2012-10-08T03:34:17Z | - |
dc.date.issued | 1992 | en_US |
dc.identifier.citation | Analytica Chimica Acta, 1992, v. 261 n. 1-2, p. 375-380 | en_US |
dc.identifier.issn | 0003-2670 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/168794 | - |
dc.description.abstract | The application of square-wave voltammetry for detection in the flow-injection determination of ascorbic acid in soft drinks and fruit juices was investigated. The pH of the solution was buffered at 2.87 to stabilize the ascorbic acid prior to analysis. Parameters such as scan rate, square-wave amplitude, step height and flow-rate of electrolyte were found to have little effect on the potential, but a significant effect on the current. The analytical current is only slightly affected by the flow-rate of the electrolyte and a maximum scan rate of 0.5 V s-1 can be used. As a compromise between sensitivity and selectivity, 40 mV was chosen as the amplitude of the square wave and 10 mV as the potential step height. Similarly, a flow-rate of 0.5 ml min-1 and an injection volume of 100 μl were chosen as a compromise between the sensitivity and resolution of the FIA method. Using the above procedures, the maximum number of samples that could be analysed was 120 h-1. The linear calibration range was from 2 x 10-6 to 6 x 10-3 M and the determination limit (10δ) was 2 x 10-7 M. No significant interference was found from additives commonly found in juices and drinks samples within their normal concentration ranges. Four juice samples were analysed using the developed method and the results were compared with those given by the established AOAC method. No significant difference was observed between the two methods used for the four samples studied. | en_US |
dc.language | eng | en_US |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/aca | en_US |
dc.relation.ispartof | Analytica Chimica Acta | en_US |
dc.subject | Ascorbic acid | - |
dc.subject | Flow system | - |
dc.subject | Fruit juices | - |
dc.subject | Soft drinks | - |
dc.subject | Voltammetry | - |
dc.title | Application of square-wave voltammetry for the determination of ascorbic acid in soft drinks and fruit juices using a flow-injection system | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Fung, YS:ysfung@hku.hk | en_US |
dc.identifier.authority | Fung, YS=rp00697 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1016/0003-2670(92)80216-T | en_US |
dc.identifier.scopus | eid_2-s2.0-0026582888 | en_US |
dc.identifier.volume | 261 | en_US |
dc.identifier.issue | 1-2 | en_US |
dc.identifier.spage | 375 | en_US |
dc.identifier.epage | 380 | en_US |
dc.identifier.isi | WOS:A1992HX85600049 | - |
dc.publisher.place | Netherlands | en_US |
dc.identifier.scopusauthorid | Fung, YS=13309754700 | en_US |
dc.identifier.scopusauthorid | Mo, SY=7004957705 | en_US |
dc.identifier.issnl | 0003-2670 | - |