File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: Metabolite profiling using a novel QqQ linear ion trap mass spectrometer
Title | Metabolite profiling using a novel QqQ linear ion trap mass spectrometer |
---|---|
Authors | |
Issue Date | 2002 |
Citation | Proceedings 50Th Asms Conference On Mass Spectrometry And Allied Topics, 2002, p. 627-628 How to Cite? |
Abstract | A novel hybrid RF/DC quadrupole-linear ion trap mass spectrometer (QqQ linear ion trap) was developed for analizing metabolite profiling. Primary hepatocyte incubations were used to demonstrate the utility of the QqQ linear ion trap mass spectrometer for metabolite profiling. High sensitivity in full scan mode MS, MS 2 and MS 3 modes, was provided by the ion trap scan functions of the QqQ linear ion trap. The flexibility to simultaneously perform quantitative and qualitative analysis was provided by MRM scan function. The experimental results show that seven major metabolites were observed during incubations. |
Persistent Identifier | http://hdl.handle.net/10722/168826 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Flarakos, T | en_US |
dc.contributor.author | Reimer, MLJ | en_US |
dc.contributor.author | Leblanc, Y | en_US |
dc.contributor.author | Chu, IK | en_US |
dc.date.accessioned | 2012-10-08T03:34:43Z | - |
dc.date.available | 2012-10-08T03:34:43Z | - |
dc.date.issued | 2002 | en_US |
dc.identifier.citation | Proceedings 50Th Asms Conference On Mass Spectrometry And Allied Topics, 2002, p. 627-628 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/168826 | - |
dc.description.abstract | A novel hybrid RF/DC quadrupole-linear ion trap mass spectrometer (QqQ linear ion trap) was developed for analizing metabolite profiling. Primary hepatocyte incubations were used to demonstrate the utility of the QqQ linear ion trap mass spectrometer for metabolite profiling. High sensitivity in full scan mode MS, MS 2 and MS 3 modes, was provided by the ion trap scan functions of the QqQ linear ion trap. The flexibility to simultaneously perform quantitative and qualitative analysis was provided by MRM scan function. The experimental results show that seven major metabolites were observed during incubations. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Proceedings 50th ASMS Conference on Mass Spectrometry and Allied Topics | en_US |
dc.title | Metabolite profiling using a novel QqQ linear ion trap mass spectrometer | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Chu, IK:ivankchu@hku.hk | en_US |
dc.identifier.authority | Chu, IK=rp00683 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.scopus | eid_2-s2.0-2442719416 | en_US |
dc.identifier.spage | 627 | en_US |
dc.identifier.epage | 628 | en_US |
dc.identifier.scopusauthorid | Flarakos, T=6508387914 | en_US |
dc.identifier.scopusauthorid | Reimer, MLJ=7004660068 | en_US |
dc.identifier.scopusauthorid | LeBlanc, Y=7004393955 | en_US |
dc.identifier.scopusauthorid | Chu, IK=7103327484 | en_US |