Article: Thermography in the determination of amputation levels in ischaemic limbs
Title | Thermography in the determination of amputation levels in ischaemic limbs |
---|---|
Authors | |
Keywords | Amputation Ischaemic limbs Thermography |
Issue Date | 1986 |
Publisher | Springer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/264 |
Citation | International Orthopaedics, 1986, v. 10 n. 2, p. 79-82 How to Cite? |
Abstract | The reliability of thermography for the determination of the level of amputation for an ischaemic lower limb was compared with that of the doppler flowmeter and the clinical judgement of an experienced surgeon. The results showed that thermography tended to overestimate the degree of ischaemia and to indicate a higher level of amputation than was necessary. The advantages and the limitations of each method are discussed. It is concluded that the clinical judgement of the surgeon was the most reliable method and that the other investigations are only an adjunct to clinical assessment. |
Persistent Identifier | http://hdl.handle.net/10722/169960 |
ISSN | 2023 Impact Factor: 2.0 2023 SCImago Journal Rankings: 0.877 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Luk, KDK | en_US |
dc.contributor.author | Yeung, PS | en_US |
dc.contributor.author | Leong, JCY | en_US |
dc.date.accessioned | 2012-10-30T06:04:23Z | - |
dc.date.available | 2012-10-30T06:04:23Z | - |
dc.date.issued | 1986 | en_US |
dc.identifier.citation | International Orthopaedics, 1986, v. 10 n. 2, p. 79-82 | en_US |
dc.identifier.issn | 0341-2695 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/169960 | - |
dc.description.abstract | The reliability of thermography for the determination of the level of amputation for an ischaemic lower limb was compared with that of the doppler flowmeter and the clinical judgement of an experienced surgeon. The results showed that thermography tended to overestimate the degree of ischaemia and to indicate a higher level of amputation than was necessary. The advantages and the limitations of each method are discussed. It is concluded that the clinical judgement of the surgeon was the most reliable method and that the other investigations are only an adjunct to clinical assessment. | en_US |
dc.language | eng | en_US |
dc.publisher | Springer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/264 | en_US |
dc.relation.ispartof | International Orthopaedics | en_US |
dc.subject | Amputation | - |
dc.subject | Ischaemic limbs | - |
dc.subject | Thermography | - |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Amputation | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Ischemia - Surgery | en_US |
dc.subject.mesh | Knee | en_US |
dc.subject.mesh | Leg - Blood Supply | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Middle Aged | en_US |
dc.subject.mesh | Rheology | en_US |
dc.subject.mesh | Thermography | en_US |
dc.title | Thermography in the determination of amputation levels in ischaemic limbs | en_US |
dc.type | Article | en_US |
dc.identifier.email | Luk, KDK:hcm21000@hku.hk | en_US |
dc.identifier.authority | Luk, KDK=rp00333 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1007/BF00267745 | - |
dc.identifier.pmid | 2943686 | - |
dc.identifier.scopus | eid_2-s2.0-0022450346 | en_US |
dc.identifier.volume | 10 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.spage | 79 | en_US |
dc.identifier.epage | 82 | en_US |
dc.identifier.isi | WOS:A1986D024300002 | - |
dc.publisher.place | Germany | en_US |
dc.identifier.scopusauthorid | Luk, KDK=7201921573 | en_US |
dc.identifier.scopusauthorid | Yeung, PS=7006727690 | en_US |
dc.identifier.scopusauthorid | Leong, JCY=35560782200 | en_US |
dc.identifier.issnl | 0341-2695 | - |