File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Unstable phalangeal fractures: Treatment by A.O. screw and plate fixation

TitleUnstable phalangeal fractures: Treatment by A.O. screw and plate fixation
Authors
Issue Date1991
PublisherWB Saunders Co. The Journal's web site is located at http://www.elsevier.com/locate/jhsa
Citation
Journal Of Hand Surgery, 1991, v. 16 n. 1, p. 113-117 How to Cite?
AbstractA prospective study of fifty-two fresh traumatic unstable fractures of the proximal or middle phalanges of the hand in forty-seven patients was reviewed. All the fractures were fixed with A.O. miniature screws and plates. The overall results were not satisfactory and complications were frequent. Only 26.9% of the fractures had good results. Fractures associated with significant soft tissue injuries had very poor results. When the present series was compared with a comparable group of fractures fixed with Kirschner wires, there was no significant improvement in the results. The unsatisfactory outcome of this group of unstable fractures may be largely due to the frequent association with poor prognostic factors.
Persistent Identifierhttp://hdl.handle.net/10722/169984
ISSN
2023 Impact Factor: 2.1
2023 SCImago Journal Rankings: 0.983
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorPun, WKen_HK
dc.contributor.authorChow, SPen_HK
dc.contributor.authorSo, YCen_HK
dc.contributor.authorLuk, KDKen_HK
dc.contributor.authorNgai, WKen_HK
dc.contributor.authorIp, FKen_HK
dc.contributor.authorPeng, WHen_HK
dc.contributor.authorNg, Cen_HK
dc.contributor.authorCrosby, Cen_HK
dc.date.accessioned2012-10-30T06:04:32Z-
dc.date.available2012-10-30T06:04:32Z-
dc.date.issued1991en_HK
dc.identifier.citationJournal Of Hand Surgery, 1991, v. 16 n. 1, p. 113-117en_HK
dc.identifier.issn0363-5023en_HK
dc.identifier.urihttp://hdl.handle.net/10722/169984-
dc.description.abstractA prospective study of fifty-two fresh traumatic unstable fractures of the proximal or middle phalanges of the hand in forty-seven patients was reviewed. All the fractures were fixed with A.O. miniature screws and plates. The overall results were not satisfactory and complications were frequent. Only 26.9% of the fractures had good results. Fractures associated with significant soft tissue injuries had very poor results. When the present series was compared with a comparable group of fractures fixed with Kirschner wires, there was no significant improvement in the results. The unsatisfactory outcome of this group of unstable fractures may be largely due to the frequent association with poor prognostic factors.en_HK
dc.languageengen_US
dc.publisherWB Saunders Co. The Journal's web site is located at http://www.elsevier.com/locate/jhsaen_HK
dc.relation.ispartofJournal of Hand Surgeryen_HK
dc.subject.meshAdolescenten_US
dc.subject.meshAdulten_US
dc.subject.meshAgeden_US
dc.subject.meshBone Platesen_US
dc.subject.meshBone Screwsen_US
dc.subject.meshBone Wiresen_US
dc.subject.meshFemaleen_US
dc.subject.meshFinger Injuries - Radiography - Surgeryen_US
dc.subject.meshFracture Fixation, Internalen_US
dc.subject.meshFractures, Bone - Radiography - Surgeryen_US
dc.subject.meshHumansen_US
dc.subject.meshMaleen_US
dc.subject.meshMiddle Ageden_US
dc.subject.meshPostoperative Complicationsen_US
dc.subject.meshProspective Studiesen_US
dc.titleUnstable phalangeal fractures: Treatment by A.O. screw and plate fixationen_HK
dc.typeArticleen_HK
dc.identifier.emailChow, SP: spchow@hku.hken_HK
dc.identifier.emailLuk, KDK: hcm21000@hku.hken_HK
dc.identifier.authorityChow, SP=rp00064en_HK
dc.identifier.authorityLuk, KDK=rp00333en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/S0363-5023(10)80023-1-
dc.identifier.pmid1995665-
dc.identifier.scopuseid_2-s2.0-0025974083en_HK
dc.identifier.volume16en_HK
dc.identifier.issue1en_HK
dc.identifier.spage113en_HK
dc.identifier.epage117en_HK
dc.identifier.isiWOS:A1991EU71600021-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridPun, WK=7003726073en_HK
dc.identifier.scopusauthoridChow, SP=7201828376en_HK
dc.identifier.scopusauthoridSo, YC=7006794052en_HK
dc.identifier.scopusauthoridLuk, KDK=7201921573en_HK
dc.identifier.scopusauthoridNgai, WK=6602875630en_HK
dc.identifier.scopusauthoridIp, FK=6603683344en_HK
dc.identifier.scopusauthoridPeng, WH=7202994978en_HK
dc.identifier.scopusauthoridNg, C=36747469700en_HK
dc.identifier.scopusauthoridCrosby, C=7004098004en_HK
dc.identifier.issnl0363-5023-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats