Article: Vacuum extractor: A safe instrument?
Title | Vacuum extractor: A safe instrument? |
---|---|
Authors | |
Issue Date | 1986 |
Publisher | Blackwell Publishing Asia. The Journal's web site is located at http://www.blackwellpublishing.com/journals/ANZJOG |
Citation | Australian And New Zealand Journal Of Obstetrics And Gynaecology, 1986, v. 26 n. 3, p. 177-181 How to Cite? |
Abstract | One thousand five hundred and twenty-six records of deliveries with vacuum extractor in 1982 and 1983 in the Hong Kong University Department of Obstetrics and Gynecology were reviewed. Vacuum extractor was found to be easy and safe to use even by inexperienced house-staff. Vacuum extractor was especially useful in the delivery of malpositioned fetal heads because of its mechanism of allowing autorotation. Its advantage of not occupying extra space in the pelvis was most beneficial to the relatively smaller Chinese pelvis. Maternal injury was uncommon. Fetal scalp injury like cephalhaematoma was not uncommon but serious scalp injury was infrequent. Perinatal mortality rate attributed to the instrument was low (0.6/1,000). However, in order to achieve safety to the mother and fetus, strict rules in application of the vacuum extractor must be observed. |
Persistent Identifier | http://hdl.handle.net/10722/173103 |
ISSN | 2023 Impact Factor: 1.4 2023 SCImago Journal Rankings: 0.630 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ngan, HYS | en_US |
dc.contributor.author | Tang, GWK | en_US |
dc.contributor.author | Ma, HK | en_US |
dc.date.accessioned | 2012-10-30T06:27:57Z | - |
dc.date.available | 2012-10-30T06:27:57Z | - |
dc.date.issued | 1986 | en_US |
dc.identifier.citation | Australian And New Zealand Journal Of Obstetrics And Gynaecology, 1986, v. 26 n. 3, p. 177-181 | en_US |
dc.identifier.issn | 0004-8666 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/173103 | - |
dc.description.abstract | One thousand five hundred and twenty-six records of deliveries with vacuum extractor in 1982 and 1983 in the Hong Kong University Department of Obstetrics and Gynecology were reviewed. Vacuum extractor was found to be easy and safe to use even by inexperienced house-staff. Vacuum extractor was especially useful in the delivery of malpositioned fetal heads because of its mechanism of allowing autorotation. Its advantage of not occupying extra space in the pelvis was most beneficial to the relatively smaller Chinese pelvis. Maternal injury was uncommon. Fetal scalp injury like cephalhaematoma was not uncommon but serious scalp injury was infrequent. Perinatal mortality rate attributed to the instrument was low (0.6/1,000). However, in order to achieve safety to the mother and fetus, strict rules in application of the vacuum extractor must be observed. | en_US |
dc.language | eng | en_US |
dc.publisher | Blackwell Publishing Asia. The Journal's web site is located at http://www.blackwellpublishing.com/journals/ANZJOG | en_US |
dc.relation.ispartof | Australian and New Zealand Journal of Obstetrics and Gynaecology | en_US |
dc.subject.mesh | Apgar Score | en_US |
dc.subject.mesh | Asphyxia Neonatorum - Etiology | en_US |
dc.subject.mesh | Birth Injuries - Etiology | en_US |
dc.subject.mesh | Birth Weight | en_US |
dc.subject.mesh | Extraction, Obstetrical - Instrumentation | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Hemorrhage - Etiology | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Infant, Newborn | en_US |
dc.subject.mesh | Jaundice, Neonatal - Etiology | en_US |
dc.subject.mesh | Pregnancy | en_US |
dc.subject.mesh | Vacuum Extraction, Obstetrical - Adverse Effects - Instrumentation | en_US |
dc.subject.mesh | Vagina - Injuries | en_US |
dc.title | Vacuum extractor: A safe instrument? | en_US |
dc.type | Article | en_US |
dc.identifier.email | Ngan, HYS:hysngan@hkucc.hku.hk | en_US |
dc.identifier.email | Tang, GWK:gwktang@hkucc.hku.hk | en_US |
dc.identifier.authority | Ngan, HYS=rp00346 | en_US |
dc.identifier.authority | Tang, GWK=rp00328 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1111/j.1479-828X.1986.tb01561.x | - |
dc.identifier.pmid | 3468937 | - |
dc.identifier.scopus | eid_2-s2.0-0022474933 | en_US |
dc.identifier.volume | 26 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.spage | 177 | en_US |
dc.identifier.epage | 181 | en_US |
dc.identifier.isi | WOS:A1986D946400004 | - |
dc.publisher.place | Australia | en_US |
dc.identifier.scopusauthorid | Ngan, HYS=34571944100 | en_US |
dc.identifier.scopusauthorid | Tang, GWK=7401633864 | en_US |
dc.identifier.scopusauthorid | Ma, HK=7403095603 | en_US |
dc.identifier.issnl | 0004-8666 | - |