Title | Magnitude and reproducibility of forces generated by clinicians during laceback placement |
---|---|
Authors | |
Keywords | Force Magnitude Lacebacks Typodont |
Issue Date | 2006 |
Publisher | Maney Publishing. The Journal's web site is located at http://www.maney.co.uk/search?fwaction=show&fwid=467 |
Citation | Journal Of Orthodontics, 2006, v. 33 n. 4, p. 270-275 How to Cite? |
Abstract | Objective: To determine the magnitude and reproducibility of forces generated by clinicians during laceback placement using a force-measuring typodont. Setting: An in vitro investigation. Materials and methods: An in vitro typodont model was developed, which incorporated strain gauges attached to a personal computer to allow measurement of the force generated on application of lacebacks. Ten operators were instructed to place lacebacks five times, on two separate occasions (T1 and T2). Inter-operator and intra-operator forces produced at T1 and T2 were compared. Main outcome measures: Forces generated by laceback placement. Results: The forces generated by clinicians ranged from 0 to 11.1 N. There were significant differences in the mean forces generated by the different operators (P<0.001), with differences between time points not being consistent across all operators (P<0.001). Some operators were more consistent than others in the forces generated. Conclusion: In vitro, there was a large inter-operator variation in the forces produced during laceback placement. With the in vitro model used in this study, few operators applied similar forces when placing lacebacks on two separate occasions. © 2001 British Orthodontic Society. |
Persistent Identifier | http://hdl.handle.net/10722/174213 |
ISSN | 2023 Impact Factor: 1.4 2023 SCImago Journal Rankings: 0.421 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Khambay, BS | en_US |
dc.contributor.author | Mchugh, S | en_US |
dc.contributor.author | Millett, DT | en_US |
dc.date.accessioned | 2012-11-22T01:58:36Z | - |
dc.date.available | 2012-11-22T01:58:36Z | - |
dc.date.issued | 2006 | en_US |
dc.identifier.citation | Journal Of Orthodontics, 2006, v. 33 n. 4, p. 270-275 | en_US |
dc.identifier.issn | 1465-3125 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/174213 | - |
dc.description.abstract | Objective: To determine the magnitude and reproducibility of forces generated by clinicians during laceback placement using a force-measuring typodont. Setting: An in vitro investigation. Materials and methods: An in vitro typodont model was developed, which incorporated strain gauges attached to a personal computer to allow measurement of the force generated on application of lacebacks. Ten operators were instructed to place lacebacks five times, on two separate occasions (T1 and T2). Inter-operator and intra-operator forces produced at T1 and T2 were compared. Main outcome measures: Forces generated by laceback placement. Results: The forces generated by clinicians ranged from 0 to 11.1 N. There were significant differences in the mean forces generated by the different operators (P<0.001), with differences between time points not being consistent across all operators (P<0.001). Some operators were more consistent than others in the forces generated. Conclusion: In vitro, there was a large inter-operator variation in the forces produced during laceback placement. With the in vitro model used in this study, few operators applied similar forces when placing lacebacks on two separate occasions. © 2001 British Orthodontic Society. | en_US |
dc.language | eng | en_US |
dc.publisher | Maney Publishing. The Journal's web site is located at http://www.maney.co.uk/search?fwaction=show&fwid=467 | en_US |
dc.relation.ispartof | Journal of Orthodontics | en_US |
dc.subject | Force Magnitude | en_US |
dc.subject | Lacebacks | en_US |
dc.subject | Typodont | en_US |
dc.title | Magnitude and reproducibility of forces generated by clinicians during laceback placement | en_US |
dc.type | Article | en_US |
dc.identifier.email | Khambay, BS: bkhambay@hku.hk | en_US |
dc.identifier.authority | Khambay, BS=rp01691 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1179/146531205225021762 | en_US |
dc.identifier.scopus | eid_2-s2.0-36549003368 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-36549003368&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 33 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.spage | 270 | en_US |
dc.identifier.epage | 275 | en_US |
dc.identifier.isi | WOS:000442872600007 | - |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.scopusauthorid | Khambay, BS=7003979053 | en_US |
dc.identifier.scopusauthorid | McHugh, S=7006653642 | en_US |
dc.identifier.scopusauthorid | Millett, DT=7005512194 | en_US |
dc.identifier.issnl | 1465-3125 | - |