File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Test-retest reliability of distortion product otoacoustic emissions in the 1 to 7 kHz range

TitleTest-retest reliability of distortion product otoacoustic emissions in the 1 to 7 kHz range
Authors
KeywordsCochlear Function
Dpoae Amplitude
Ototoxic Medication
Issue Date2005
PublisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/1651386x.asp
Citation
Audiological Medicine, 2005, v. 3 n. 2, p. 108-115 How to Cite?
AbstractDistortion product otoacoustic emissions (DPOAEs) are regularly used to measure cochlear status in the high frequency range, as when monitoring ototoxic medication or for assessing noise-induced hearing loss. This study measured default DP-gram protocols and user-defined DP spectrum protocols in 35 normal hearing young adults using Otodynamics ILO96 equipment. Very short-term and short-term reliability was assessed, with measures conducted 20 minutes, and an average of 15 days later, respectively. The test resolution setting for the DP-gram measurements was varied between 1 to 8 points per octave in each test series. DPOAE amplitudes in the default frequency range (1 to 6 kHz) between test and short-term retest were highly correlated, with average r = 0.81. Standard error of measurement (SEM) was found to average 2.64 dB for DPOAE amplitude in the default frequency range. DPOAE amplitudes in the higher frequency range of 6.5 to 7 kHz were also significantly correlated between test and short-term retest; r ranged from 0.80 to 0.82 and SEM ranged from 2.59 to 3.04 dB. The various resolution and retest conditions showed no significant differences in reliability. DPOAE measurement in the 6.5 to 7 kHz range can be considered a reliable tool for monitoring cochlear function in cases such as exposure to ototoxic medication or noise. © 2005 Taylor & Francis.
Persistent Identifierhttp://hdl.handle.net/10722/175287
ISSN
References

 

DC FieldValueLanguage
dc.contributor.authorNg, IHYen_US
dc.contributor.authorMcpherson, Ben_US
dc.date.accessioned2012-11-26T08:57:58Z-
dc.date.available2012-11-26T08:57:58Z-
dc.date.issued2005en_US
dc.identifier.citationAudiological Medicine, 2005, v. 3 n. 2, p. 108-115en_US
dc.identifier.issn1651-386Xen_US
dc.identifier.urihttp://hdl.handle.net/10722/175287-
dc.description.abstractDistortion product otoacoustic emissions (DPOAEs) are regularly used to measure cochlear status in the high frequency range, as when monitoring ototoxic medication or for assessing noise-induced hearing loss. This study measured default DP-gram protocols and user-defined DP spectrum protocols in 35 normal hearing young adults using Otodynamics ILO96 equipment. Very short-term and short-term reliability was assessed, with measures conducted 20 minutes, and an average of 15 days later, respectively. The test resolution setting for the DP-gram measurements was varied between 1 to 8 points per octave in each test series. DPOAE amplitudes in the default frequency range (1 to 6 kHz) between test and short-term retest were highly correlated, with average r = 0.81. Standard error of measurement (SEM) was found to average 2.64 dB for DPOAE amplitude in the default frequency range. DPOAE amplitudes in the higher frequency range of 6.5 to 7 kHz were also significantly correlated between test and short-term retest; r ranged from 0.80 to 0.82 and SEM ranged from 2.59 to 3.04 dB. The various resolution and retest conditions showed no significant differences in reliability. DPOAE measurement in the 6.5 to 7 kHz range can be considered a reliable tool for monitoring cochlear function in cases such as exposure to ototoxic medication or noise. © 2005 Taylor & Francis.en_US
dc.languageengen_US
dc.publisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/1651386x.aspen_US
dc.relation.ispartofAudiological Medicineen_US
dc.subjectCochlear Functionen_US
dc.subjectDpoae Amplitudeen_US
dc.subjectOtotoxic Medicationen_US
dc.titleTest-retest reliability of distortion product otoacoustic emissions in the 1 to 7 kHz rangeen_US
dc.typeArticleen_US
dc.identifier.emailMcpherson, B: dbmcpher@hkucc.hku.hken_US
dc.identifier.authorityMcpherson, B=rp00937en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1080/16513860510028284en_US
dc.identifier.scopuseid_2-s2.0-22344435820en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-22344435820&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume3en_US
dc.identifier.issue2en_US
dc.identifier.spage108en_US
dc.identifier.epage115en_US
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridNg, IHY=36829683900en_US
dc.identifier.scopusauthoridMcpherson, B=7006800770en_US
dc.identifier.citeulike10601909-
dc.identifier.issnl1651-3835-

Export via OAI-PMH Interface in XML Formats