File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: A review of otoacoustic emission hearing screening technology

TitleA review of otoacoustic emission hearing screening technology
Authors
KeywordsNeonatal Hearing Screening
Otoacoustic Emission
Signal-To-Noise Ratio
Time-Frequency Analysis
Issue Date2008
PublisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/1651386x.asp
Citation
Audiological Medicine, 2008, v. 6 n. 2, p. 100-114 How to Cite?
AbstractOtoacoustic emissions (OAEs) have attracted a great deal of interest from audiologists, biophysicists, cell biologists, and engineers worldwide. Despite great achievements having been made in recent years, many theoretical and practical aspects of OAE assessment still remain to be explored. One important area of focus for further OAE research is the development of optimal recording techniques and methods of data processing, which are expected to offer: 1) an improvement in the amplitude and the SNR of the OAE response, and thus increase the pass rate in newborn hearing screening; and 2) a decrease in OAE acquisition time. This paper examines the current limitations of OAE recording for neonatal hearing screening, analyses the possible reasons for these constraints, and reviews possible clinical and technological solutions that have been considered to date. © 2008 Taylor & Francis.
Persistent Identifierhttp://hdl.handle.net/10722/175300
ISSN
References

 

DC FieldValueLanguage
dc.contributor.authorZhang, VWen_US
dc.contributor.authorMcpherson, Ben_US
dc.date.accessioned2012-11-26T08:58:02Z-
dc.date.available2012-11-26T08:58:02Z-
dc.date.issued2008en_US
dc.identifier.citationAudiological Medicine, 2008, v. 6 n. 2, p. 100-114en_US
dc.identifier.issn1651-386Xen_US
dc.identifier.urihttp://hdl.handle.net/10722/175300-
dc.description.abstractOtoacoustic emissions (OAEs) have attracted a great deal of interest from audiologists, biophysicists, cell biologists, and engineers worldwide. Despite great achievements having been made in recent years, many theoretical and practical aspects of OAE assessment still remain to be explored. One important area of focus for further OAE research is the development of optimal recording techniques and methods of data processing, which are expected to offer: 1) an improvement in the amplitude and the SNR of the OAE response, and thus increase the pass rate in newborn hearing screening; and 2) a decrease in OAE acquisition time. This paper examines the current limitations of OAE recording for neonatal hearing screening, analyses the possible reasons for these constraints, and reviews possible clinical and technological solutions that have been considered to date. © 2008 Taylor & Francis.en_US
dc.languageengen_US
dc.publisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/1651386x.aspen_US
dc.relation.ispartofAudiological Medicineen_US
dc.subjectNeonatal Hearing Screeningen_US
dc.subjectOtoacoustic Emissionen_US
dc.subjectSignal-To-Noise Ratioen_US
dc.subjectTime-Frequency Analysisen_US
dc.titleA review of otoacoustic emission hearing screening technologyen_US
dc.typeArticleen_US
dc.identifier.emailMcPherson, B: dbmcpher@hkucc.hku.hken_US
dc.identifier.authorityMcPherson, B=rp00937en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1080/16513860701633326en_US
dc.identifier.scopuseid_2-s2.0-45849127938en_US
dc.identifier.hkuros143676-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-45849127938&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume6en_US
dc.identifier.issue2en_US
dc.identifier.spage100en_US
dc.identifier.epage114en_US
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridZhang, VW=23101824900en_US
dc.identifier.scopusauthoridMcPherson, B=7006800770en_US
dc.identifier.issnl1651-3835-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats