Article: Face validity, construct validity and training benefits of a virtual reality turp simulator

TitleFace validity, construct validity and training benefits of a virtual reality turp simulator
Authors
KeywordsSimulation
Turp
Validity
Virtual Reality
Issue Date2012
PublisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/ijsu
Citation
International Journal Of Surgery, 2012, v. 10 n. 3, p. 163-166 How to Cite?
AbstractObjective: To assess face validity, construct validity and the training benefits of a virtual reality TURP simulator. Method: 11 novices (no TURP experience) and 7 experts (>200 TURP's) completed a virtual reality median lobe prostate resection task on the TURPsim™ (Simbionix USA Corp., Cleveland, OH). Performance indicators (percentage of prostate resected (PR), percentage of capsular resection (CR) and time diathermy loop active without tissue contact (TAWC) were recorded via the TURPsim™ and compared between novices and experts to assess construct validity. Verbal comments provided by experts following task completion were used to assess face validity. Repeated attempts of the task by the novices were analysed to assess the training benefits of the TURPsim™. Results: Experts resected a significantly greater percentage of prostate per minute (p < 0.01) and had significantly less active diathermy time without tissue contact (p < 0.01) than novices. After practice, novices were able to perform the simulation more effectively, with significant improvement in all measured parameters. Improvement in performance was noted in novices following repetitive training, as evidenced by improved TAWC scores that were not significantly different from the expert group (p = 0.18). Conclusions: This study has established face and construct validity for the TURPsim™. The potential benefit in using this tool to train novices has also been demonstrated. © 2012 Surgical Associates Ltd.
Persistent Identifierhttp://hdl.handle.net/10722/176079
ISSN
2023 Impact Factor: 12.5
2023 SCImago Journal Rankings: 2.895
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorBright, Een_US
dc.contributor.authorVine, Sen_US
dc.contributor.authorWilson, MRen_US
dc.contributor.authorMasters, RSWen_US
dc.contributor.authorMcgrath, JSen_US
dc.date.accessioned2012-11-26T09:04:54Z-
dc.date.available2012-11-26T09:04:54Z-
dc.date.issued2012en_US
dc.identifier.citationInternational Journal Of Surgery, 2012, v. 10 n. 3, p. 163-166en_US
dc.identifier.issn1743-9191en_US
dc.identifier.urihttp://hdl.handle.net/10722/176079-
dc.description.abstractObjective: To assess face validity, construct validity and the training benefits of a virtual reality TURP simulator. Method: 11 novices (no TURP experience) and 7 experts (>200 TURP's) completed a virtual reality median lobe prostate resection task on the TURPsim™ (Simbionix USA Corp., Cleveland, OH). Performance indicators (percentage of prostate resected (PR), percentage of capsular resection (CR) and time diathermy loop active without tissue contact (TAWC) were recorded via the TURPsim™ and compared between novices and experts to assess construct validity. Verbal comments provided by experts following task completion were used to assess face validity. Repeated attempts of the task by the novices were analysed to assess the training benefits of the TURPsim™. Results: Experts resected a significantly greater percentage of prostate per minute (p < 0.01) and had significantly less active diathermy time without tissue contact (p < 0.01) than novices. After practice, novices were able to perform the simulation more effectively, with significant improvement in all measured parameters. Improvement in performance was noted in novices following repetitive training, as evidenced by improved TAWC scores that were not significantly different from the expert group (p = 0.18). Conclusions: This study has established face and construct validity for the TURPsim™. The potential benefit in using this tool to train novices has also been demonstrated. © 2012 Surgical Associates Ltd.en_US
dc.languageengen_US
dc.publisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/ijsuen_US
dc.relation.ispartofInternational Journal of Surgeryen_US
dc.subjectSimulationen_US
dc.subjectTurpen_US
dc.subjectValidityen_US
dc.subjectVirtual Realityen_US
dc.titleFace validity, construct validity and training benefits of a virtual reality turp simulatoren_US
dc.typeArticleen_US
dc.identifier.emailMasters, RSW: mastersr@hku.hken_US
dc.identifier.authorityMasters, RSW=rp00935en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/j.ijsu.2012.02.012en_US
dc.identifier.pmid22366646-
dc.identifier.scopuseid_2-s2.0-84863410195en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-84863410195&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume10en_US
dc.identifier.issue3en_US
dc.identifier.spage163en_US
dc.identifier.epage166en_US
dc.identifier.isiWOS:000307638600013-
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridBright, E=15069550000en_US
dc.identifier.scopusauthoridVine, S=36811509000en_US
dc.identifier.scopusauthoridWilson, MR=7408663801en_US
dc.identifier.scopusauthoridMasters, RSW=7102880488en_US
dc.identifier.scopusauthoridMcGrath, JS=12774961300en_US
dc.identifier.issnl1743-9159-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats