File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Trans-abdominal ultrasound-guided suprapubic puncture of a non-deflating Foley catheter balloon

TitleTrans-abdominal ultrasound-guided suprapubic puncture of a non-deflating Foley catheter balloon
Authors
KeywordsBladder
Equipment Failure
Ultrasonography
Urinary Catheterisation
Issue Date2005
PublisherMedcom Limited. The Journal's web site is located at http://www.hkcem.com/html/publications/
Citation
Hong Kong Journal Of Emergency Medicine, 2005, v. 12 n. 1, p. 42-45 How to Cite?
AbstractFailure of a Foley catheter balloon to deflate is a frustrating problem to both the patient and the doctor. We report a case of non-deflating Foley catheter balloon successfully deflated by needle puncture via the suprapubic route under trans-abdominal ultrasound guidance by emergency physicians. The procedure is simple and safe. We believe that all emergency physicians with adequate knowledge and minimal training can acquire the technique. The choices of different methods to deflate the balloon are also discussed.
Persistent Identifierhttp://hdl.handle.net/10722/178854
ISSN
2021 Impact Factor: 0.529
2020 SCImago Journal Rankings: 0.145
References

 

DC FieldValueLanguage
dc.contributor.authorLee, WMMen_US
dc.contributor.authorTsui, KLen_US
dc.contributor.authorKam, CWen_US
dc.date.accessioned2012-12-19T09:50:11Z-
dc.date.available2012-12-19T09:50:11Z-
dc.date.issued2005en_US
dc.identifier.citationHong Kong Journal Of Emergency Medicine, 2005, v. 12 n. 1, p. 42-45en_US
dc.identifier.issn1024-9079en_US
dc.identifier.urihttp://hdl.handle.net/10722/178854-
dc.description.abstractFailure of a Foley catheter balloon to deflate is a frustrating problem to both the patient and the doctor. We report a case of non-deflating Foley catheter balloon successfully deflated by needle puncture via the suprapubic route under trans-abdominal ultrasound guidance by emergency physicians. The procedure is simple and safe. We believe that all emergency physicians with adequate knowledge and minimal training can acquire the technique. The choices of different methods to deflate the balloon are also discussed.en_US
dc.languageengen_US
dc.publisherMedcom Limited. The Journal's web site is located at http://www.hkcem.com/html/publications/en_US
dc.relation.ispartofHong Kong Journal of Emergency Medicineen_US
dc.subjectBladderen_US
dc.subjectEquipment Failureen_US
dc.subjectUltrasonographyen_US
dc.subjectUrinary Catheterisationen_US
dc.titleTrans-abdominal ultrasound-guided suprapubic puncture of a non-deflating Foley catheter balloonen_US
dc.typeArticleen_US
dc.identifier.emailLee, WMM: hrszlwm@hku.hken_US
dc.identifier.authorityLee, WMM=rp00728en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.scopuseid_2-s2.0-13444279004en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-13444279004&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume12en_US
dc.identifier.issue1en_US
dc.identifier.spage42en_US
dc.identifier.epage45en_US
dc.publisher.placeHong Kongen_US
dc.identifier.scopusauthoridLee, WMM=24799156600en_US
dc.identifier.scopusauthoridTsui, KL=35745300400en_US
dc.identifier.scopusauthoridKam, CW=7102416674en_US
dc.identifier.issnl1024-9079-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats