File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: Comparing the sensitivity of ionization chamber array to film and point dose measurement for IMRT delivery errors

TitleComparing the sensitivity of ionization chamber array to film and point dose measurement for IMRT delivery errors
Authors
KeywordsMedical sciences physics
Issue Date2009
PublisherAmerican Association of Physicists in Medicine. The Journal's web site is located at http://ojps.aip.org/medphys
Citation
The 51st Annual Meeting and Exhibition of The American Association for Physicists in Medicine (AAPM 2009), Anaheim, CA., 26-30 July 2009. In Medical Physics, 2009, v. 36 n. 6, p. 2572 How to Cite?
AbstractPURPOSE: To compare the sensitivity of 2D ion chamber array, film dosimetry and point dose measurement for detecting IMRT delivery errors. METHOD AND MATERIALS: 2 types of IMRT delivery errors were considered. First type involved adding 1 mm systematic error to 1 bank of the MLC leaves, resulting in a dose discrepancy of ≥ 5%. The second type involved ‘undeliverable intensity patterns’, resulting from improper use of smoothness constraint during optimization. 4 and 2 plans were studied for type 1 and …
DescriptionTherapy General Poster Discussion: SU‐FF‐T‐226
Abstract no. 10625
Persistent Identifierhttp://hdl.handle.net/10722/183924
ISSN
2023 Impact Factor: 3.2
2023 SCImago Journal Rankings: 1.052
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorNg, CYen_US
dc.contributor.authorLi, Hen_US
dc.contributor.authorKwong, L-
dc.contributor.authorLaw, M-
dc.contributor.authorWu, P-
dc.date.accessioned2013-06-18T04:28:42Z-
dc.date.available2013-06-18T04:28:42Z-
dc.date.issued2009en_US
dc.identifier.citationThe 51st Annual Meeting and Exhibition of The American Association for Physicists in Medicine (AAPM 2009), Anaheim, CA., 26-30 July 2009. In Medical Physics, 2009, v. 36 n. 6, p. 2572en_US
dc.identifier.issn0094-2405-
dc.identifier.urihttp://hdl.handle.net/10722/183924-
dc.descriptionTherapy General Poster Discussion: SU‐FF‐T‐226-
dc.descriptionAbstract no. 10625-
dc.description.abstractPURPOSE: To compare the sensitivity of 2D ion chamber array, film dosimetry and point dose measurement for detecting IMRT delivery errors. METHOD AND MATERIALS: 2 types of IMRT delivery errors were considered. First type involved adding 1 mm systematic error to 1 bank of the MLC leaves, resulting in a dose discrepancy of ≥ 5%. The second type involved ‘undeliverable intensity patterns’, resulting from improper use of smoothness constraint during optimization. 4 and 2 plans were studied for type 1 and …-
dc.languageengen_US
dc.publisherAmerican Association of Physicists in Medicine. The Journal's web site is located at http://ojps.aip.org/medphys-
dc.relation.ispartofMedical Physicsen_US
dc.subjectMedical sciences physics-
dc.titleComparing the sensitivity of ionization chamber array to film and point dose measurement for IMRT delivery errorsen_US
dc.typeConference_Paperen_US
dc.identifier.emailNg, CY: ngchoryi@hku.hken_US
dc.description.naturepostprint-
dc.identifier.doi10.1118/1.3181702-
dc.identifier.scopuseid_2-s2.0-85024811787-
dc.identifier.hkuros214649en_US
dc.identifier.volume36-
dc.identifier.issue6-
dc.identifier.spage2572-
dc.identifier.epage2572-
dc.identifier.isiWOS:000411575400023-
dc.publisher.placeUnited States-
dc.identifier.issnl0094-2405-

Export via OAI-PMH Interface in XML Formats


OR