File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Real time analysis of fingerpulse plethysmographic signal and its application on pulse oximetry

TitleReal time analysis of fingerpulse plethysmographic signal and its application on pulse oximetry
Authors
Issue Date1994
Citation
Biomedical Engineering - Applications, Basis and Communications, 1994, v. 6 n. 6, p. 878-884 How to Cite?
AbstractPulse oximetry is an innovative technique for continuous noninvasive monitoring of arterial blood oxygen saturation value. It has proved to be very useful for many applications such as clinical management of critically ill infants with cardiac and pulmonary diseases and patient monitoring during surgery. Signal processing algorithm on plethysmographic fingerpulse signal is typically completed in time domain utilizing moving average and peak detection technique. However, it suffers from false detection and errors due to motion artifacts. In this paper, we present an improved method by computing the scaling factor between the red and infrared ac signal. Real-time computer programs are implemented on a personal computer to process the optical sensor output and estimate the desired parameters. Experimental results are provided to illustrate the dramatic improvement.
Persistent Identifierhttp://hdl.handle.net/10722/196624
ISSN

 

DC FieldValueLanguage
dc.contributor.authorLai, KT-
dc.contributor.authorYau, SF-
dc.contributor.authorCheung, PW-
dc.date.accessioned2014-04-24T02:10:28Z-
dc.date.available2014-04-24T02:10:28Z-
dc.date.issued1994-
dc.identifier.citationBiomedical Engineering - Applications, Basis and Communications, 1994, v. 6 n. 6, p. 878-884-
dc.identifier.issn1016-2356-
dc.identifier.urihttp://hdl.handle.net/10722/196624-
dc.description.abstractPulse oximetry is an innovative technique for continuous noninvasive monitoring of arterial blood oxygen saturation value. It has proved to be very useful for many applications such as clinical management of critically ill infants with cardiac and pulmonary diseases and patient monitoring during surgery. Signal processing algorithm on plethysmographic fingerpulse signal is typically completed in time domain utilizing moving average and peak detection technique. However, it suffers from false detection and errors due to motion artifacts. In this paper, we present an improved method by computing the scaling factor between the red and infrared ac signal. Real-time computer programs are implemented on a personal computer to process the optical sensor output and estimate the desired parameters. Experimental results are provided to illustrate the dramatic improvement.-
dc.languageeng-
dc.relation.ispartofBiomedical Engineering - Applications, Basis and Communications-
dc.titleReal time analysis of fingerpulse plethysmographic signal and its application on pulse oximetry-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-0028735510-
dc.identifier.volume6-
dc.identifier.issue6-
dc.identifier.spage878-
dc.identifier.epage884-
dc.identifier.issnl1016-2356-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats