Article: Twenty-four-hour intraocular pressure related changes following adjuvant selective laser trabeculoplasty for normal tension glaucoma
Title | Twenty-four-hour intraocular pressure related changes following adjuvant selective laser trabeculoplasty for normal tension glaucoma |
---|---|
Authors | |
Issue Date | 2014 |
Citation | Medicine, 2014, v. 93 n. 27, p. article no. e238 How to Cite? |
Abstract | To investigate intraocular pressure (IOP) related patterns before and after selective laser trabeculoplasty (SLT) for normal tension glaucoma (NTG).In this prospective cohort study, 18 NTG patients underwent SLT. Success was defined as IOP reduction >/= 20% by Goldmann applanation tonometry. 24-hour IOP-related pattern recording with a contact lens sensor (CLS) (SENSIMED Triggerfish, Sensimed, Switzerland) was done before (baseline) and 1 month after SLT. A cosine function was fitted to the mean CLS patterns for each individual in the SLT success and non-success groups and the amplitude before and after SLT was calculated. Diurnal, nocturnal, and 24-hour CLS pattern local variability was determined for pre- and post-SLT sessions. Cosine amplitude and variability were compared before and after SLT by group using paired t-tests, with alpha = 0.05. Patients (11 women, 7 men) had a mean age of 65.1 +/- 13.7 years. Mean IOP was 15.3 +/- 2.2 mm Hg at baseline and was reduced by 17.0% to 12.7 +/- 1.8 mm Hg 1 month after SLT (P = 0.001). SLT was successful in 8 patients (44%). The amplitude of the fitted cosine was reduced by 24.6% in the success group, but displayed an amplitude increase of 19.2% post-SLT in the non-success group. Higher diurnal local variability of the CLS pattern was observed after SLT in non-success subjects (P = 0.002), while nocturnal variability showed no significant change. The increase in diurnal variability in the non-success group led to an increase in 24-hour variability in this group (P = 0.001). No change in local variability (diurnal, nocturnal, and 24-hour) was seen in the success group. The IOP-related pattern cosinor amplitude was reduced in NTG patients with a successful SLT treatment whereas the non-success group exhibited an increase of cosine amplitude. Higher diurnal and 24-hour CLS pattern variability was observed in non-success patients 1 month post-SLT. |
Persistent Identifier | http://hdl.handle.net/10722/208488 |
ISSN | 2023 Impact Factor: 1.3 2023 SCImago Journal Rankings: 0.441 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, WYJ | en_US |
dc.contributor.author | Fu, L | en_US |
dc.contributor.author | Chan, JC | en_US |
dc.contributor.author | Lai, JS | en_US |
dc.date.accessioned | 2015-03-11T07:06:22Z | - |
dc.date.available | 2015-03-11T07:06:22Z | - |
dc.date.issued | 2014 | en_US |
dc.identifier.citation | Medicine, 2014, v. 93 n. 27, p. article no. e238 | en_US |
dc.identifier.issn | 0025-7974 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/208488 | - |
dc.description.abstract | To investigate intraocular pressure (IOP) related patterns before and after selective laser trabeculoplasty (SLT) for normal tension glaucoma (NTG).In this prospective cohort study, 18 NTG patients underwent SLT. Success was defined as IOP reduction >/= 20% by Goldmann applanation tonometry. 24-hour IOP-related pattern recording with a contact lens sensor (CLS) (SENSIMED Triggerfish, Sensimed, Switzerland) was done before (baseline) and 1 month after SLT. A cosine function was fitted to the mean CLS patterns for each individual in the SLT success and non-success groups and the amplitude before and after SLT was calculated. Diurnal, nocturnal, and 24-hour CLS pattern local variability was determined for pre- and post-SLT sessions. Cosine amplitude and variability were compared before and after SLT by group using paired t-tests, with alpha = 0.05. Patients (11 women, 7 men) had a mean age of 65.1 +/- 13.7 years. Mean IOP was 15.3 +/- 2.2 mm Hg at baseline and was reduced by 17.0% to 12.7 +/- 1.8 mm Hg 1 month after SLT (P = 0.001). SLT was successful in 8 patients (44%). The amplitude of the fitted cosine was reduced by 24.6% in the success group, but displayed an amplitude increase of 19.2% post-SLT in the non-success group. Higher diurnal local variability of the CLS pattern was observed after SLT in non-success subjects (P = 0.002), while nocturnal variability showed no significant change. The increase in diurnal variability in the non-success group led to an increase in 24-hour variability in this group (P = 0.001). No change in local variability (diurnal, nocturnal, and 24-hour) was seen in the success group. The IOP-related pattern cosinor amplitude was reduced in NTG patients with a successful SLT treatment whereas the non-success group exhibited an increase of cosine amplitude. Higher diurnal and 24-hour CLS pattern variability was observed in non-success patients 1 month post-SLT. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Medicine | en_US |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.title | Twenty-four-hour intraocular pressure related changes following adjuvant selective laser trabeculoplasty for normal tension glaucoma | en_US |
dc.type | Article | en_US |
dc.identifier.email | Lee, WYJ: jackylee@hku.hk | en_US |
dc.identifier.authority | Lee, WYJ=rp01498 | en_US |
dc.description.nature | published_or_final_version | - |
dc.identifier.doi | 10.1097/MD.0000000000000238 | en_US |
dc.identifier.scopus | eid_2-s2.0-84919388684 | - |
dc.identifier.hkuros | 280743 | - |
dc.identifier.hkuros | 280744 | - |
dc.identifier.volume | 93 | en_US |
dc.identifier.issue | 27 | en_US |
dc.identifier.spage | article no. e238 | en_US |
dc.identifier.epage | article no. e238 | en_US |
dc.identifier.isi | WOS:000346406500043 | - |
dc.customcontrol.immutable | csl 171204 | - |
dc.identifier.issnl | 0025-7974 | - |