File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.neuroimage.2013.01.038
- Scopus: eid_2-s2.0-84873702566
- PMID: 23370063
- WOS: WOS:000317166800005
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE)
Title | A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE) |
---|---|
Authors | |
Keywords | Multi-shot echo-planar imaging Interleaved echo-planar imaging Multiplexed sensitivity-encoding Inherent phase correction Diffusion weighted imaging |
Issue Date | 2013 |
Citation | NeuroImage, 2013, v. 72, p. 41-47 How to Cite? |
Abstract | Diffusion weighted magnetic resonance imaging (DWI) data have been mostly acquired with single-shot echo-planar imaging (EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in single-shot EPI, even when the parallel imaging (usually at an acceleration factor of 2) is incorporated. Multi-shot acquisition strategies could potentially achieve higher spatial resolution and fidelity, but they are generally susceptible to motion-induced phase errors among excitations that are exacerbated by diffusion sensitizing gradients, rendering the reconstructed images unusable. It has been shown that shot-to-shot phase variations may be corrected using navigator echoes, but at the cost of imaging throughput. To address these challenges, a novel and robust multi-shot DWI technique, termed multiplexed sensitivity-encoding (MUSE), is developed here to reliably and inherently correct nonlinear shot-to-shot phase variations without the use of navigator echoes. The performance of the MUSE technique is confirmed experimentally in healthy adult volunteers on 3. Tesla MRI systems. This newly developed technique should prove highly valuable for mapping brain structures and connectivities at high spatial resolution for neuroscience studies. © 2013 Elsevier Inc. |
Persistent Identifier | http://hdl.handle.net/10722/210111 |
ISSN | 2023 Impact Factor: 4.7 2023 SCImago Journal Rankings: 2.436 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chen, Nan kuei | - |
dc.contributor.author | Guidon, Arnaud | - |
dc.contributor.author | Chang, Hing Chiu | - |
dc.contributor.author | Song, Allen W. | - |
dc.date.accessioned | 2015-05-22T06:06:40Z | - |
dc.date.available | 2015-05-22T06:06:40Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | NeuroImage, 2013, v. 72, p. 41-47 | - |
dc.identifier.issn | 1053-8119 | - |
dc.identifier.uri | http://hdl.handle.net/10722/210111 | - |
dc.description.abstract | Diffusion weighted magnetic resonance imaging (DWI) data have been mostly acquired with single-shot echo-planar imaging (EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in single-shot EPI, even when the parallel imaging (usually at an acceleration factor of 2) is incorporated. Multi-shot acquisition strategies could potentially achieve higher spatial resolution and fidelity, but they are generally susceptible to motion-induced phase errors among excitations that are exacerbated by diffusion sensitizing gradients, rendering the reconstructed images unusable. It has been shown that shot-to-shot phase variations may be corrected using navigator echoes, but at the cost of imaging throughput. To address these challenges, a novel and robust multi-shot DWI technique, termed multiplexed sensitivity-encoding (MUSE), is developed here to reliably and inherently correct nonlinear shot-to-shot phase variations without the use of navigator echoes. The performance of the MUSE technique is confirmed experimentally in healthy adult volunteers on 3. Tesla MRI systems. This newly developed technique should prove highly valuable for mapping brain structures and connectivities at high spatial resolution for neuroscience studies. © 2013 Elsevier Inc. | - |
dc.language | eng | - |
dc.relation.ispartof | NeuroImage | - |
dc.subject | Multi-shot echo-planar imaging | - |
dc.subject | Interleaved echo-planar imaging | - |
dc.subject | Multiplexed sensitivity-encoding | - |
dc.subject | Inherent phase correction | - |
dc.subject | Diffusion weighted imaging | - |
dc.title | A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE) | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.neuroimage.2013.01.038 | - |
dc.identifier.pmid | 23370063 | - |
dc.identifier.scopus | eid_2-s2.0-84873702566 | - |
dc.identifier.volume | 72 | - |
dc.identifier.spage | 41 | - |
dc.identifier.epage | 47 | - |
dc.identifier.eissn | 1095-9572 | - |
dc.identifier.isi | WOS:000317166800005 | - |
dc.identifier.issnl | 1053-8119 | - |