File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.acra.2014.12.017
- Scopus: eid_2-s2.0-84926964942
- PMID: 25683499
- WOS: WOS:000353078600004
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Model-Based Iterative Reconstruction in Low-Dose CT Colonography-Feasibility Study in 65 Patients for Symptomatic Investigation
Title | Model-Based Iterative Reconstruction in Low-Dose CT Colonography-Feasibility Study in 65 Patients for Symptomatic Investigation |
---|---|
Authors | |
Keywords | CT colonography Low dose MBIR Model-based iterative reconstruction |
Issue Date | 2015 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/arad |
Citation | Academic Radiology, 2015, v. 22 n. 5, p. 563-571 How to Cite? |
Abstract | RATIONALE AND OBJECTIVES: To compare image quality on computed tomographic colonography (CTC) acquired at standard dose (STD) and low dose (LD) using filtered-back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) techniques. MATERIALS AND METHODS: A total of 65 symptomatic patients were prospectively enrolled for the study and underwent STD and LD CTC with filtered-back projection, adaptive statistical iterative reconstruction, and MBIR to allow direct per-patient comparison. Objective image noise, subjective image analyses, and polyp detection were assessed. RESULTS: Objective image noise analysis demonstrates significant noise reduction using MBIR technique (P < .05) despite being acquired at lower doses. Subjective image analyses were superior for LD MBIR in all parameters except visibility of extracolonic lesions (two-dimensional) and visibility of colonic wall (three-dimensional) where there were no significant differences. There was no significant difference in polyp detection rates (P > .05). Doses: LD (dose-length product, 257.7), STD (dose-length product, 483.6). CONCLUSIONS: LD MBIR CTC objectively shows improved image noise using parameters in our study. Subjectively, image quality is maintained. Polyp detection shows no significant difference but because of small numbers needs further validation. Average dose reduction of 47% can be achieved. This study confirms feasibility of using MBIR in this context of CTC in symptomatic population. |
Persistent Identifier | http://hdl.handle.net/10722/210719 |
ISSN | 2023 Impact Factor: 3.8 2023 SCImago Journal Rankings: 1.062 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Vardhanabhuti, V | - |
dc.contributor.author | James, J | - |
dc.contributor.author | Nensey, R | - |
dc.contributor.author | Hyde, C | - |
dc.contributor.author | Roobottom, C | - |
dc.date.accessioned | 2015-06-23T05:48:21Z | - |
dc.date.available | 2015-06-23T05:48:21Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Academic Radiology, 2015, v. 22 n. 5, p. 563-571 | - |
dc.identifier.issn | 1076-6332 | - |
dc.identifier.uri | http://hdl.handle.net/10722/210719 | - |
dc.description.abstract | RATIONALE AND OBJECTIVES: To compare image quality on computed tomographic colonography (CTC) acquired at standard dose (STD) and low dose (LD) using filtered-back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) techniques. MATERIALS AND METHODS: A total of 65 symptomatic patients were prospectively enrolled for the study and underwent STD and LD CTC with filtered-back projection, adaptive statistical iterative reconstruction, and MBIR to allow direct per-patient comparison. Objective image noise, subjective image analyses, and polyp detection were assessed. RESULTS: Objective image noise analysis demonstrates significant noise reduction using MBIR technique (P < .05) despite being acquired at lower doses. Subjective image analyses were superior for LD MBIR in all parameters except visibility of extracolonic lesions (two-dimensional) and visibility of colonic wall (three-dimensional) where there were no significant differences. There was no significant difference in polyp detection rates (P > .05). Doses: LD (dose-length product, 257.7), STD (dose-length product, 483.6). CONCLUSIONS: LD MBIR CTC objectively shows improved image noise using parameters in our study. Subjectively, image quality is maintained. Polyp detection shows no significant difference but because of small numbers needs further validation. Average dose reduction of 47% can be achieved. This study confirms feasibility of using MBIR in this context of CTC in symptomatic population. | - |
dc.language | eng | - |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/arad | - |
dc.relation.ispartof | Academic Radiology | - |
dc.subject | CT colonography | - |
dc.subject | Low dose | - |
dc.subject | MBIR | - |
dc.subject | Model-based iterative reconstruction | - |
dc.title | Model-Based Iterative Reconstruction in Low-Dose CT Colonography-Feasibility Study in 65 Patients for Symptomatic Investigation | - |
dc.type | Article | - |
dc.identifier.email | Vardhanabhuti, V: varv@hku.hk | - |
dc.identifier.authority | Vardhanabhuti, V=rp01900 | - |
dc.identifier.doi | 10.1016/j.acra.2014.12.017 | - |
dc.identifier.pmid | 25683499 | - |
dc.identifier.scopus | eid_2-s2.0-84926964942 | - |
dc.identifier.hkuros | 243525 | - |
dc.identifier.volume | 22 | - |
dc.identifier.issue | 5 | - |
dc.identifier.spage | 563 | - |
dc.identifier.epage | 571 | - |
dc.identifier.isi | WOS:000353078600004 | - |
dc.publisher.place | Netherlands | - |
dc.identifier.issnl | 1076-6332 | - |