File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: An integrated dual sensor system automatically optimized by target rate histogram

TitleAn integrated dual sensor system automatically optimized by target rate histogram
Authors
KeywordsAutomatic optimization
Sensor combination
Target rate histogram
Issue Date1998
PublisherPace College.
Citation
PACE, 1998, v. 21 n. 8, p. 1559-1566 How to Cite?
AbstractThe use of combined sensors and advanced algorithms using different principles can improve rate performance over a single sensor system. Combinations of sensors and more sophisticated algorithms, however, invariably increase the complexity of pacemaker programming. An automatically optimized combined minute ventilation and activity DDDR pacemaker was developed to minimize repeated sensor adjustment. The device used subthreshold (below cardiac stimulation threshold) lead impedance to detect lead configuration at implantation automatically, followed by “implant management,” including setting of lead polarity and initiation of DDDR pacing. Automatic sensor adaptation was achieved by programming a “target rate histogram” based on the patient's activity level and frequency of exertion, and the rate profile optimization process matched the recorded integrated sensor response to the target rate histogram profile. In nine patients implanted with the DX2 pacemakers, the implant management gave 100% accuracy in the detection of lead polarity. Rate profile optinuzation automatically increased the pacing rate during exercise between discharge and 3-month follow-up (hall walk: 78 ± 3 vs 98 ± 3 beats/min, and maximal treadmill exercise: 89 ± 6 vs 115 ± 5 beats/min, P < 0.001) with a significant increase in exercise duration during maximal exercise (7.18 ± 1 min vs 9.56 ± 2 min, P = 0.05). The accuracy of rate profile optimization versus manual programming was assessed at 1 month, and there was no significant difference between pacing rate kinetics and maximal pacing rate between the two methods of programming. In conclusion, pacemaker automaticity can be initiated at implantation and the self-optimized rate adaptive response appeared to be comparable to that derived from a manual programming procedure, which may reduce the need to perform time consuming sensor programming.
Persistent Identifierhttp://hdl.handle.net/10722/224307
ISSN
2023 Impact Factor: 1.7
2023 SCImago Journal Rankings: 0.579
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLeung, SK-
dc.contributor.authorLau, CP-
dc.contributor.authorTang, MO-
dc.contributor.authorLeung, Z-
dc.contributor.authorYakimow, K-
dc.date.accessioned2016-03-31T08:15:15Z-
dc.date.available2016-03-31T08:15:15Z-
dc.date.issued1998-
dc.identifier.citationPACE, 1998, v. 21 n. 8, p. 1559-1566-
dc.identifier.issn0147-8389-
dc.identifier.urihttp://hdl.handle.net/10722/224307-
dc.description.abstractThe use of combined sensors and advanced algorithms using different principles can improve rate performance over a single sensor system. Combinations of sensors and more sophisticated algorithms, however, invariably increase the complexity of pacemaker programming. An automatically optimized combined minute ventilation and activity DDDR pacemaker was developed to minimize repeated sensor adjustment. The device used subthreshold (below cardiac stimulation threshold) lead impedance to detect lead configuration at implantation automatically, followed by “implant management,” including setting of lead polarity and initiation of DDDR pacing. Automatic sensor adaptation was achieved by programming a “target rate histogram” based on the patient's activity level and frequency of exertion, and the rate profile optimization process matched the recorded integrated sensor response to the target rate histogram profile. In nine patients implanted with the DX2 pacemakers, the implant management gave 100% accuracy in the detection of lead polarity. Rate profile optinuzation automatically increased the pacing rate during exercise between discharge and 3-month follow-up (hall walk: 78 ± 3 vs 98 ± 3 beats/min, and maximal treadmill exercise: 89 ± 6 vs 115 ± 5 beats/min, P < 0.001) with a significant increase in exercise duration during maximal exercise (7.18 ± 1 min vs 9.56 ± 2 min, P = 0.05). The accuracy of rate profile optimization versus manual programming was assessed at 1 month, and there was no significant difference between pacing rate kinetics and maximal pacing rate between the two methods of programming. In conclusion, pacemaker automaticity can be initiated at implantation and the self-optimized rate adaptive response appeared to be comparable to that derived from a manual programming procedure, which may reduce the need to perform time consuming sensor programming.-
dc.languageeng-
dc.publisherPace College.-
dc.relation.ispartofPACE-
dc.subjectAutomatic optimization-
dc.subjectSensor combination-
dc.subjectTarget rate histogram-
dc.subject.meshArrhythmias, Cardiac - physiopathology - therapy-
dc.subject.meshElectronics, Medical - instrumentation-
dc.subject.meshHeart Rate-
dc.subject.meshPacemaker, Artificial-
dc.subject.meshProspective Studies-
dc.titleAn integrated dual sensor system automatically optimized by target rate histogram-
dc.typeArticle-
dc.identifier.emailLau, CP: cplau@hku.hk-
dc.identifier.emailTang, MO: motang@hkucc.hku.hk-
dc.identifier.doi10.1111/j.1540-8159.1998.tb00243.x-
dc.identifier.pmid9725154-
dc.identifier.scopuseid_2-s2.0-0031826754-
dc.identifier.hkuros40415-
dc.identifier.volume21-
dc.identifier.issue8-
dc.identifier.spage1559-
dc.identifier.epage1566-
dc.identifier.eissn1540-8159-
dc.identifier.isiWOS:000075350100008-
dc.publisher.placeUnited States-
dc.identifier.issnl0147-8389-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats