Conference Paper: Reconstruction of under-sampled Propeller gradient-echo image using projection onto convex sets based multiplexed sensitivity-encoding (POCSMUSE)
Title | Reconstruction of under-sampled Propeller gradient-echo image using projection onto convex sets based multiplexed sensitivity-encoding (POCSMUSE) |
---|---|
Authors | |
Issue Date | 2016 |
Citation | The 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016), Singapore, 7-13 May 2016. How to Cite? |
Abstract | The Propeller technique is a useful acquisition scheme and reconstruction method to reduce motion artifact. However, the higher specific absorption rate (SAR) of RF pulse at high-field magnetic strength can limit the number of multiple slices for a given TR, which in turn reduces the efficiency of acquisition, especially for Propeller-FSE sequence. A possible solution is to reduce the echo-train-length with under-sampling of data of each blade. In this study, we propose to apply POCSMUSE instead of SENSE reconstruction and Propeller reconstruction, to reconstruct the image from all under-sampled blade data with reduced noise amplification. The data acquired from brain and liver using Propeller-GRE will be used to test purposed POCSMUSE algorithm. |
Description | Electronic Poster Session: Acquisition, Reconstruction & Analysis 2 - Motion Correction: no. 4248 |
Persistent Identifier | http://hdl.handle.net/10722/225008 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chang, HCC | - |
dc.contributor.author | Chu, ML | - |
dc.contributor.author | Chen, NK | - |
dc.date.accessioned | 2016-04-18T03:35:18Z | - |
dc.date.available | 2016-04-18T03:35:18Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | The 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016), Singapore, 7-13 May 2016. | - |
dc.identifier.uri | http://hdl.handle.net/10722/225008 | - |
dc.description | Electronic Poster Session: Acquisition, Reconstruction & Analysis 2 - Motion Correction: no. 4248 | - |
dc.description.abstract | The Propeller technique is a useful acquisition scheme and reconstruction method to reduce motion artifact. However, the higher specific absorption rate (SAR) of RF pulse at high-field magnetic strength can limit the number of multiple slices for a given TR, which in turn reduces the efficiency of acquisition, especially for Propeller-FSE sequence. A possible solution is to reduce the echo-train-length with under-sampling of data of each blade. In this study, we propose to apply POCSMUSE instead of SENSE reconstruction and Propeller reconstruction, to reconstruct the image from all under-sampled blade data with reduced noise amplification. The data acquired from brain and liver using Propeller-GRE will be used to test purposed POCSMUSE algorithm. | - |
dc.language | eng | - |
dc.relation.ispartof | Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine, ISMRM 2016 | - |
dc.title | Reconstruction of under-sampled Propeller gradient-echo image using projection onto convex sets based multiplexed sensitivity-encoding (POCSMUSE) | - |
dc.type | Conference_Paper | - |
dc.identifier.email | Chang, HCC: hcchang@hku.hk | - |
dc.identifier.authority | Chang, HCC=rp02024 | - |
dc.identifier.hkuros | 257578 | - |