Article: Feasibility of a Chest-worn accelerometer for physical activity measurement
Title | Feasibility of a Chest-worn accelerometer for physical activity measurement |
---|---|
Authors | |
Keywords | Measurement Activity monitors Actigraph Wrist worn Treadmill |
Issue Date | 2016 |
Publisher | Elsevier Australia. The Journal's web site is located at http://www.elsevier.com/wps/find/journaldescription.cws_home/707423/description?navopenmenu=-2 |
Citation | Journal of Science and Medicine in Sport, 2016 How to Cite? |
Abstract | Objectives
A 'proof-of-concept' study to examine the feasibility of wearing an Actigraph GT3X+ at the Chest (resembling a neck pendant) for physical activity measurement.
Design
A convenience sample of 45 healthy adults (23 male, mean age 20.0 ± 4.5 years) was included in data analysis.
Methods
Participants simultaneously wore three GT3X+ accelerometers, on the Waist, Wrist, and Chest and completed 8 bouts of slow (.67, .89, 1.11 m/s), average (1.33, 1.56, 1.78 m/s) and fast (2.00, 2.22 m/s) walking on a treadmill. Paired t-test, correlations and absolute percentage errors (APE) of accelerometer output (vector magnitude, VM) were computed for the key pairs: Waist–Wrist; and Waist–Chest.
Results
The Wrist-site overestimated VM to a greater extent at all speeds in comparison to the Chest. Pearson's r correlations were weaker for Waist–Wrist (<.80) in comparison to the Waist–Chest (>.85). The APE's were much lower (i.e. higher agreement) for the Chest (9.23–15.5%) compared to the Wrist (19.7–54.9%). Participants also felt the Chest-site was more acceptable than the Waist-site.
Conclusions
PA measurements recorded by a Chest worn GT3X+ more closely resembled PA measurements recorded at the traditional Waist site than when compared to the Wrist site. When combined with high Chest site preference, the findings of our study suggest that the Chest is a feasible site for accelerometer wear. |
Persistent Identifier | http://hdl.handle.net/10722/232170 |
ISSN | 2023 Impact Factor: 3.0 2023 SCImago Journal Rankings: 1.222 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhang, JH | - |
dc.contributor.author | Macfarlane, DJ | - |
dc.contributor.author | Sobko, T | - |
dc.date.accessioned | 2016-09-20T05:28:12Z | - |
dc.date.available | 2016-09-20T05:28:12Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Journal of Science and Medicine in Sport, 2016 | - |
dc.identifier.issn | 1440-2440 | - |
dc.identifier.uri | http://hdl.handle.net/10722/232170 | - |
dc.description.abstract | Objectives A 'proof-of-concept' study to examine the feasibility of wearing an Actigraph GT3X+ at the Chest (resembling a neck pendant) for physical activity measurement. Design A convenience sample of 45 healthy adults (23 male, mean age 20.0 ± 4.5 years) was included in data analysis. Methods Participants simultaneously wore three GT3X+ accelerometers, on the Waist, Wrist, and Chest and completed 8 bouts of slow (.67, .89, 1.11 m/s), average (1.33, 1.56, 1.78 m/s) and fast (2.00, 2.22 m/s) walking on a treadmill. Paired t-test, correlations and absolute percentage errors (APE) of accelerometer output (vector magnitude, VM) were computed for the key pairs: Waist–Wrist; and Waist–Chest. Results The Wrist-site overestimated VM to a greater extent at all speeds in comparison to the Chest. Pearson's r correlations were weaker for Waist–Wrist (<.80) in comparison to the Waist–Chest (>.85). The APE's were much lower (i.e. higher agreement) for the Chest (9.23–15.5%) compared to the Wrist (19.7–54.9%). Participants also felt the Chest-site was more acceptable than the Waist-site. Conclusions PA measurements recorded by a Chest worn GT3X+ more closely resembled PA measurements recorded at the traditional Waist site than when compared to the Wrist site. When combined with high Chest site preference, the findings of our study suggest that the Chest is a feasible site for accelerometer wear. | - |
dc.language | eng | - |
dc.publisher | Elsevier Australia. The Journal's web site is located at http://www.elsevier.com/wps/find/journaldescription.cws_home/707423/description?navopenmenu=-2 | - |
dc.relation.ispartof | Journal of Science and Medicine in Sport | - |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.subject | Measurement | - |
dc.subject | Activity monitors | - |
dc.subject | Actigraph | - |
dc.subject | Wrist worn | - |
dc.subject | Treadmill | - |
dc.title | Feasibility of a Chest-worn accelerometer for physical activity measurement | - |
dc.type | Article | - |
dc.identifier.email | Macfarlane, DJ: djmac@hku.hk | - |
dc.identifier.email | Sobko, T: tsobko@hku.hk | - |
dc.identifier.authority | Macfarlane, DJ=rp00934 | - |
dc.identifier.authority | Sobko, T=rp01843 | - |
dc.description.nature | postprint | - |
dc.identifier.doi | 10.1016/j.jsams.2016.03.004 | - |
dc.identifier.pmid | 27017012 | - |
dc.identifier.scopus | eid_2-s2.0-84962590513 | - |
dc.identifier.hkuros | 265617 | - |
dc.identifier.isi | WOS:000390973000012 | - |
dc.publisher.place | Australia | - |
dc.identifier.issnl | 1878-1861 | - |