File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Development of Implant Stability Quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants

TitleDevelopment of Implant Stability Quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants
Authors
KeywordsResonance frequency analysis
SLActive
Sinus floor elevation
Autogenous bone grafts
Implant Stability Quotient
Early implant loading
Deproteinized bovine bone mineral
Dental implant
Issue Date2017
Citation
Clinical Oral Implants Research, 2017, v. 28 n. 1, p. 109-115 How to Cite?
Abstract© 2016 John Wiley & Sons A/S.Objectives: In patients with implant placement and simultaneous sinus floor elevation (SFE), healing periods of 6 months have been the standard of care for more than 25 years. The primary objective of this prospective case series study was to determine what percentage of implants placed with SFE reach a threshold Implant Stability Quotient (ISQ) of ≥70 after 8 weeks of healing using Resonance Frequency Analysis (RFA). Material and Methods: A total of 109 dental implants were placed in 97 patients. SFE was carried out with a lateral window approach and a mixture of autogenous bone chips and deproteinized bovine bone mineral (DBBM). Titanium screw-type, tissue-level implants with a chemically modified SLA surface were used. ISQ values were measured after implant insertion (ISQBL) and after 8 weeks of healing (ISQ8 wk). Patients showing ISQ8 wk ≥ 70 subsequently underwent restoration. Implants with an ISQ value < 70 were recalled at 2-week intervals. Results: The ISQ at baseline had a mean value of 68.3 (SD ± 9.8). At 8 weeks, the mean ISQ value was 73.6 (SD ± 6.4). This increase was statistically significant (P < 0.001). An ISQ8 wk value ≥70 was observed for 91 implants (83%). One implant (0.9%) with a peri-implant infection and severe bone loss at 8 weeks was considered an early failure. Conclusions: This study showed that 83% of implants reached the threshold level of ISQ ≥ 70 after 8 weeks, allowing an early loading protocol. The early failure rate was considered low with 0.9%. The RFA technology is a suitable method to objectively monitor implant stability longitudinally.
Persistent Identifierhttp://hdl.handle.net/10722/236071
ISSN
2023 Impact Factor: 4.8
2023 SCImago Journal Rankings: 1.865
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorKuchler, Ulrike-
dc.contributor.authorChappuis, Vivianne-
dc.contributor.authorBornstein, Michael M.-
dc.contributor.authorSiewczyk, Marta-
dc.contributor.authorGruber, Reinhard-
dc.contributor.authorMaestre, Laura-
dc.contributor.authorBuser, Daniel-
dc.date.accessioned2016-11-11T07:42:52Z-
dc.date.available2016-11-11T07:42:52Z-
dc.date.issued2017-
dc.identifier.citationClinical Oral Implants Research, 2017, v. 28 n. 1, p. 109-115-
dc.identifier.issn0905-7161-
dc.identifier.urihttp://hdl.handle.net/10722/236071-
dc.description.abstract© 2016 John Wiley & Sons A/S.Objectives: In patients with implant placement and simultaneous sinus floor elevation (SFE), healing periods of 6 months have been the standard of care for more than 25 years. The primary objective of this prospective case series study was to determine what percentage of implants placed with SFE reach a threshold Implant Stability Quotient (ISQ) of ≥70 after 8 weeks of healing using Resonance Frequency Analysis (RFA). Material and Methods: A total of 109 dental implants were placed in 97 patients. SFE was carried out with a lateral window approach and a mixture of autogenous bone chips and deproteinized bovine bone mineral (DBBM). Titanium screw-type, tissue-level implants with a chemically modified SLA surface were used. ISQ values were measured after implant insertion (ISQBL) and after 8 weeks of healing (ISQ8 wk). Patients showing ISQ8 wk ≥ 70 subsequently underwent restoration. Implants with an ISQ value < 70 were recalled at 2-week intervals. Results: The ISQ at baseline had a mean value of 68.3 (SD ± 9.8). At 8 weeks, the mean ISQ value was 73.6 (SD ± 6.4). This increase was statistically significant (P < 0.001). An ISQ8 wk value ≥70 was observed for 91 implants (83%). One implant (0.9%) with a peri-implant infection and severe bone loss at 8 weeks was considered an early failure. Conclusions: This study showed that 83% of implants reached the threshold level of ISQ ≥ 70 after 8 weeks, allowing an early loading protocol. The early failure rate was considered low with 0.9%. The RFA technology is a suitable method to objectively monitor implant stability longitudinally.-
dc.languageeng-
dc.relation.ispartofClinical Oral Implants Research-
dc.subjectResonance frequency analysis-
dc.subjectSLActive-
dc.subjectSinus floor elevation-
dc.subjectAutogenous bone grafts-
dc.subjectImplant Stability Quotient-
dc.subjectEarly implant loading-
dc.subjectDeproteinized bovine bone mineral-
dc.subjectDental implant-
dc.titleDevelopment of Implant Stability Quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1111/clr.12768-
dc.identifier.scopuseid_2-s2.0-84955561031-
dc.identifier.hkuros271083-
dc.identifier.volume28-
dc.identifier.issue1-
dc.identifier.spage109-
dc.identifier.epage115-
dc.identifier.eissn1600-0501-
dc.identifier.isiWOS:000394181300015-
dc.identifier.issnl0905-7161-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats