File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Case series: Stability of contour augmentation and esthetic outcomes of implant-supported single crowns in the esthetic zone: 3-year results of a prospective study with early implant placement postextraction

TitleCase series: Stability of contour augmentation and esthetic outcomes of implant-supported single crowns in the esthetic zone: 3-year results of a prospective study with early implant placement postextraction
Authors
KeywordsBone regeneration
Early placement
Dental implant
Bone-level
Clinical trial
Gingival recession
Implants
Bone graft
Issue Date2011
Citation
Journal of Periodontology, 2011, v. 82, n. 3, p. 342-349 How to Cite?
AbstractBackground: Early implant placement is one of the treatment options after tooth extraction. Implant surgery is performed after a healing period of 4 to 8 weeks and combined with a simultaneous contour augmentation using the guided bone regeneration technique to rebuild stable esthetic facial hard- and soft-tissue contours. Methods: In this prospective study, 20 patients were treated with an implant-born single crown and followed for 3 years. Clinical, radiologic, and esthetic parameters were recorded to assess treatment outcomes. Results: At the 3-year examination, all 20 implants were successfully integrated, demonstrating ankylotic stability and healthy peri-implant soft tissues as documented by standard clinical parameters. Esthetic outcomes were assessed by the pink esthetic score (PES) and white esthetic score (WES) and confirmed pleasing results overall. WES values were slightly superior to PES values. Periapical radiographs showed minimal crestal bone loss around used bone-level implants with a mean bone loss of 0.18 mm at 3 years. Only two implants revealed bone loss between 0.5 and 1.0 mm. One of these implants had minor mucosal recession ≤1.0 mm. Conclusions: This prospective study evaluates the concept of early implant placement and demonstrated successful tissue integration for all 20 implants and stable bone-crest levels around implant-abutment interfaces according to the platform-switching concept. The midterm 3-year followup revealed pleasing esthetic outcomes and stable facial soft tissues. The risk of mucosal recession was low, with only one patient showing minor recession of the facial mucosa. These encouraging results need to be confirmed with a 5-year follow-up examination.
Persistent Identifierhttp://hdl.handle.net/10722/236171
ISSN
2023 Impact Factor: 4.2
2023 SCImago Journal Rankings: 1.362
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorBuser, Daniel-
dc.contributor.authorWittneben, Julia-
dc.contributor.authorBornstein, Michael M.-
dc.contributor.authorGrütter, Linda-
dc.contributor.authorChappuis, Vivianne-
dc.contributor.authorBelser, Urs C.-
dc.date.accessioned2016-11-11T07:43:08Z-
dc.date.available2016-11-11T07:43:08Z-
dc.date.issued2011-
dc.identifier.citationJournal of Periodontology, 2011, v. 82, n. 3, p. 342-349-
dc.identifier.issn0022-3492-
dc.identifier.urihttp://hdl.handle.net/10722/236171-
dc.description.abstractBackground: Early implant placement is one of the treatment options after tooth extraction. Implant surgery is performed after a healing period of 4 to 8 weeks and combined with a simultaneous contour augmentation using the guided bone regeneration technique to rebuild stable esthetic facial hard- and soft-tissue contours. Methods: In this prospective study, 20 patients were treated with an implant-born single crown and followed for 3 years. Clinical, radiologic, and esthetic parameters were recorded to assess treatment outcomes. Results: At the 3-year examination, all 20 implants were successfully integrated, demonstrating ankylotic stability and healthy peri-implant soft tissues as documented by standard clinical parameters. Esthetic outcomes were assessed by the pink esthetic score (PES) and white esthetic score (WES) and confirmed pleasing results overall. WES values were slightly superior to PES values. Periapical radiographs showed minimal crestal bone loss around used bone-level implants with a mean bone loss of 0.18 mm at 3 years. Only two implants revealed bone loss between 0.5 and 1.0 mm. One of these implants had minor mucosal recession ≤1.0 mm. Conclusions: This prospective study evaluates the concept of early implant placement and demonstrated successful tissue integration for all 20 implants and stable bone-crest levels around implant-abutment interfaces according to the platform-switching concept. The midterm 3-year followup revealed pleasing esthetic outcomes and stable facial soft tissues. The risk of mucosal recession was low, with only one patient showing minor recession of the facial mucosa. These encouraging results need to be confirmed with a 5-year follow-up examination.-
dc.languageeng-
dc.relation.ispartofJournal of Periodontology-
dc.subjectBone regeneration-
dc.subjectEarly placement-
dc.subjectDental implant-
dc.subjectBone-level-
dc.subjectClinical trial-
dc.subjectGingival recession-
dc.subjectImplants-
dc.subjectBone graft-
dc.titleCase series: Stability of contour augmentation and esthetic outcomes of implant-supported single crowns in the esthetic zone: 3-year results of a prospective study with early implant placement postextraction-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1902/jop.2010.100408-
dc.identifier.pmid20831371-
dc.identifier.scopuseid_2-s2.0-79952799160-
dc.identifier.volume82-
dc.identifier.issue3-
dc.identifier.spage342-
dc.identifier.epage349-
dc.identifier.isiWOS:000288587200002-
dc.identifier.issnl0022-3492-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats