File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.ajem.2016.12.046
- Scopus: eid_2-s2.0-85009250491
- WOS: WOS:000394924600026
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Using color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position
Title | Using color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position |
---|---|
Authors | |
Keywords | Sensitivity Nasogastric tube Air insufflation Color Doppler Ultrasound Specificity |
Issue Date | 2017 |
Citation | American Journal of Emergency Medicine, 2017, v. 35, n. 2, p. 333-336 How to Cite? |
Abstract | © 2016 Elsevier Inc.Objectives Previous studies have shown that ultrasonography (USG), as an alternative to radiography, has a good accuracy in confirming nasogastric tube (NGT) position. Color flow detection of air insufflation is a novel approach in verifying NGT position. In our study, we aimed at evaluating its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in confirming the NGT position, as compared with 2-dimensional (2D) USG. Methods The study was conducted on adult patients over a period of 38 months in an emergency department in Hong Kong. 2D USG and color flow Doppler imaging were conducted for each subject. Chest X-ray was used as the gold standard for NGT position confirmation. Results 100 patients (59 males and 41 females) were recruited totally. Their mean age was 82. The sensitivity, specificity, PPV and NPV of 2D USG were 11.1% (95% CI 4.6%–17.6%), 100% (95% CI 100%–100%), 100% (95% CI 100%–100%), and 11.1% (95% CI 4.6%–17.6%) respectively. For color flow Doppler USG, the sensitivity, specificity, PPV and NPV were 90% (95% CI 83.7%–96.2%), 80% (95% CI 55.2%–100%), 97.6% (95% CI 94.3%–100%), and 47.1% (95% CI 23.3%–70.8%) respectively. The overall accuracy of color Doppler imaging was 89%, which was higher than that of 2D USG (20% only). Conclusions Color flow detection of air insufflation improves the diagnostic accuracy of ultrasound in verifying NGT position. It is a quick investigation such that fasting time of patients and their length of ED stay can be shortened. |
Persistent Identifier | http://hdl.handle.net/10722/239775 |
ISSN | 2023 Impact Factor: 2.7 2023 SCImago Journal Rankings: 0.858 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wong, Kin Wa | - |
dc.contributor.author | Chan, Hok Hang | - |
dc.contributor.author | Wong, Chi Pang | - |
dc.contributor.author | Chan, Ming Yin | - |
dc.contributor.author | Chau, Jeffrey Cheuk Wai | - |
dc.contributor.author | Wong, Tai Wai | - |
dc.date.accessioned | 2017-04-03T02:41:23Z | - |
dc.date.available | 2017-04-03T02:41:23Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | American Journal of Emergency Medicine, 2017, v. 35, n. 2, p. 333-336 | - |
dc.identifier.issn | 0735-6757 | - |
dc.identifier.uri | http://hdl.handle.net/10722/239775 | - |
dc.description.abstract | © 2016 Elsevier Inc.Objectives Previous studies have shown that ultrasonography (USG), as an alternative to radiography, has a good accuracy in confirming nasogastric tube (NGT) position. Color flow detection of air insufflation is a novel approach in verifying NGT position. In our study, we aimed at evaluating its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in confirming the NGT position, as compared with 2-dimensional (2D) USG. Methods The study was conducted on adult patients over a period of 38 months in an emergency department in Hong Kong. 2D USG and color flow Doppler imaging were conducted for each subject. Chest X-ray was used as the gold standard for NGT position confirmation. Results 100 patients (59 males and 41 females) were recruited totally. Their mean age was 82. The sensitivity, specificity, PPV and NPV of 2D USG were 11.1% (95% CI 4.6%–17.6%), 100% (95% CI 100%–100%), 100% (95% CI 100%–100%), and 11.1% (95% CI 4.6%–17.6%) respectively. For color flow Doppler USG, the sensitivity, specificity, PPV and NPV were 90% (95% CI 83.7%–96.2%), 80% (95% CI 55.2%–100%), 97.6% (95% CI 94.3%–100%), and 47.1% (95% CI 23.3%–70.8%) respectively. The overall accuracy of color Doppler imaging was 89%, which was higher than that of 2D USG (20% only). Conclusions Color flow detection of air insufflation improves the diagnostic accuracy of ultrasound in verifying NGT position. It is a quick investigation such that fasting time of patients and their length of ED stay can be shortened. | - |
dc.language | eng | - |
dc.relation.ispartof | American Journal of Emergency Medicine | - |
dc.subject | Sensitivity | - |
dc.subject | Nasogastric tube | - |
dc.subject | Air insufflation | - |
dc.subject | Color Doppler | - |
dc.subject | Ultrasound | - |
dc.subject | Specificity | - |
dc.title | Using color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.ajem.2016.12.046 | - |
dc.identifier.scopus | eid_2-s2.0-85009250491 | - |
dc.identifier.volume | 35 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 333 | - |
dc.identifier.epage | 336 | - |
dc.identifier.eissn | 1532-8171 | - |
dc.identifier.isi | WOS:000394924600026 | - |
dc.identifier.issnl | 0735-6757 | - |