File Download

There are no files associated with this item.

Conference Paper: 3D multi-band interleaved DW-EPI with 3D phase correction

Title3D multi-band interleaved DW-EPI with 3D phase correction
Authors
Issue Date2017
PublisherInternational Society for Magnetic Resonance in Medicine.
Citation
The 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM), Honolulu, HI., 22-27 April 2017. In Conference Proceedings, 2017, abstract no. 524 How to Cite?
AbstractThe optimal SNR efficiency of 3D multi-slab multi-shot DWI acquisition can be enabled by using a TR range of 1-2s. However, due to the low feasible slab thickness, the multi-slab acquisition can only achieve limited brain coverage when using a short TR. In this study, we first develop a 3D multi-band (MB) iDW-EPI sequence with MB-EVI-based navigator to increase brain coverage when using optimal TR. Second, we extend 3D-MUSER algorithm, which is proposed in another study, to reconstruct 3D-MB-iDW-EPI data with 3D phase correction. Our preliminary result demonstrates the feasibility of 3D MB DWI with 3D phase correction.
Persistent Identifierhttp://hdl.handle.net/10722/240982

 

DC FieldValueLanguage
dc.contributor.authorChang, HCC-
dc.contributor.authorHui, SK-
dc.contributor.authorLiu, X-
dc.contributor.authorChen, NK-
dc.date.accessioned2017-05-22T09:20:33Z-
dc.date.available2017-05-22T09:20:33Z-
dc.date.issued2017-
dc.identifier.citationThe 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM), Honolulu, HI., 22-27 April 2017. In Conference Proceedings, 2017, abstract no. 524-
dc.identifier.urihttp://hdl.handle.net/10722/240982-
dc.description.abstractThe optimal SNR efficiency of 3D multi-slab multi-shot DWI acquisition can be enabled by using a TR range of 1-2s. However, due to the low feasible slab thickness, the multi-slab acquisition can only achieve limited brain coverage when using a short TR. In this study, we first develop a 3D multi-band (MB) iDW-EPI sequence with MB-EVI-based navigator to increase brain coverage when using optimal TR. Second, we extend 3D-MUSER algorithm, which is proposed in another study, to reconstruct 3D-MB-iDW-EPI data with 3D phase correction. Our preliminary result demonstrates the feasibility of 3D MB DWI with 3D phase correction.-
dc.languageeng-
dc.publisherInternational Society for Magnetic Resonance in Medicine.-
dc.relation.ispartofISMRM 2017 Annual Meeting & Exhibition Proceedings-
dc.title3D multi-band interleaved DW-EPI with 3D phase correction-
dc.typeConference_Paper-
dc.identifier.emailChang, HCC: hcchang@hku.hk-
dc.identifier.emailHui, SK: edshui@hku.hk-
dc.identifier.authorityChang, HCC=rp02024-
dc.identifier.authorityHui, SK=rp01832-
dc.identifier.hkuros272198-
dc.publisher.placeUnited States-

Export via OAI-PMH Interface in XML Formats