Conference Paper: Mathematical Modeling for Evaluating Gustatory Stimulation of Parotid Gland by Proton Density MRI

TitleMathematical Modeling for Evaluating Gustatory Stimulation of Parotid Gland by Proton Density MRI
Authors
Issue Date2017
PublisherInternational Society for Magnetic Resonance in Medicine (ISMRM).
Citation
The International Society for Magnetic Resonance in Medicine (ISMRM) 25th Annual Meeting & Exhibition, Honolulu, HI, 22-27 April 2017 How to Cite?
AbstractThe parotid gland function is evaluated by gustatory stimulation using scintigraphy in clinic. Due to the saliva secretion of parotid, it is supposed to measure the water component of parotid gland using PD MRI instead of scintigraphy. Normally the drop magnitude and recover rate of signal-time curve after gustatory stimulation was used to evaluate the function of parotid gland. For more physiology and quantitative parameters of characteristics of signal-time curve, we developed a mathematical model for drainage and refill of a toilet tank to quantify the parotid gland function in this study.
Persistent Identifierhttp://hdl.handle.net/10722/246305

 

DC FieldValueLanguage
dc.contributor.authorCheng, YC-
dc.contributor.authorLiu, YJ-
dc.contributor.authorLee, YH-
dc.contributor.authorChang, HCC-
dc.contributor.authorChiu, HC-
dc.contributor.authorChiu, TW-
dc.contributor.authorHsu, K-
dc.contributor.authorHsu, HH-
dc.contributor.authorJuan, CJ-
dc.date.accessioned2017-09-18T02:26:10Z-
dc.date.available2017-09-18T02:26:10Z-
dc.date.issued2017-
dc.identifier.citationThe International Society for Magnetic Resonance in Medicine (ISMRM) 25th Annual Meeting & Exhibition, Honolulu, HI, 22-27 April 2017-
dc.identifier.urihttp://hdl.handle.net/10722/246305-
dc.description.abstractThe parotid gland function is evaluated by gustatory stimulation using scintigraphy in clinic. Due to the saliva secretion of parotid, it is supposed to measure the water component of parotid gland using PD MRI instead of scintigraphy. Normally the drop magnitude and recover rate of signal-time curve after gustatory stimulation was used to evaluate the function of parotid gland. For more physiology and quantitative parameters of characteristics of signal-time curve, we developed a mathematical model for drainage and refill of a toilet tank to quantify the parotid gland function in this study.-
dc.languageeng-
dc.publisherInternational Society for Magnetic Resonance in Medicine (ISMRM). -
dc.relation.ispartofThe International Society for Magnetic Resonance in Medicine (ISMRM) Annual Meeting & Exhibition-
dc.titleMathematical Modeling for Evaluating Gustatory Stimulation of Parotid Gland by Proton Density MRI-