File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Appears in Collections:
Conference Paper: Mathematical Modeling for Evaluating Gustatory Stimulation of Parotid Gland by Proton Density MRI
Title | Mathematical Modeling for Evaluating Gustatory Stimulation of Parotid Gland by Proton Density MRI |
---|---|
Authors | |
Issue Date | 2017 |
Publisher | International Society for Magnetic Resonance in Medicine (ISMRM). |
Citation | The International Society for Magnetic Resonance in Medicine (ISMRM) 25th Annual Meeting & Exhibition, Honolulu, HI, 22-27 April 2017 How to Cite? |
Abstract | The parotid gland function is evaluated by gustatory stimulation using scintigraphy in clinic. Due to the saliva secretion of parotid, it is supposed to measure the water component of parotid gland using PD MRI instead of scintigraphy. Normally the drop magnitude and recover rate of signal-time curve after gustatory stimulation was used to evaluate the function of parotid gland. For more physiology and quantitative parameters of characteristics of signal-time curve, we developed a mathematical model for drainage and refill of a toilet tank to quantify the parotid gland function in this study. |
Persistent Identifier | http://hdl.handle.net/10722/246305 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cheng, YC | - |
dc.contributor.author | Liu, YJ | - |
dc.contributor.author | Lee, YH | - |
dc.contributor.author | Chang, HCC | - |
dc.contributor.author | Chiu, HC | - |
dc.contributor.author | Chiu, TW | - |
dc.contributor.author | Hsu, K | - |
dc.contributor.author | Hsu, HH | - |
dc.contributor.author | Juan, CJ | - |
dc.date.accessioned | 2017-09-18T02:26:10Z | - |
dc.date.available | 2017-09-18T02:26:10Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | The International Society for Magnetic Resonance in Medicine (ISMRM) 25th Annual Meeting & Exhibition, Honolulu, HI, 22-27 April 2017 | - |
dc.identifier.uri | http://hdl.handle.net/10722/246305 | - |
dc.description.abstract | The parotid gland function is evaluated by gustatory stimulation using scintigraphy in clinic. Due to the saliva secretion of parotid, it is supposed to measure the water component of parotid gland using PD MRI instead of scintigraphy. Normally the drop magnitude and recover rate of signal-time curve after gustatory stimulation was used to evaluate the function of parotid gland. For more physiology and quantitative parameters of characteristics of signal-time curve, we developed a mathematical model for drainage and refill of a toilet tank to quantify the parotid gland function in this study. | - |
dc.language | eng | - |
dc.publisher | International Society for Magnetic Resonance in Medicine (ISMRM). | - |
dc.relation.ispartof | The International Society for Magnetic Resonance in Medicine (ISMRM) Annual Meeting & Exhibition | - |
dc.title | Mathematical Modeling for Evaluating Gustatory Stimulation of Parotid Gland by Proton Density MRI | - |
dc.type | Conference_Paper | - |
dc.identifier.email | Chang, HCC: hcchang@hku.hk | - |
dc.identifier.authority | Chang, HCC=rp02024 | - |
dc.identifier.hkuros | 277083 | - |
dc.publisher.place | Honolulu, HI | - |