Article: Bearing Factors of Cold-formed Stainless Steel Double Shear Bolted Connections at Elevated Temperatures
Title | Bearing Factors of Cold-formed Stainless Steel Double Shear Bolted Connections at Elevated Temperatures |
---|---|
Authors | |
Keywords | Bearing strength Bolt hole deformation Bolted connection Finite element analysis Reliability analysis Stainless steel |
Issue Date | 2016 |
Publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/tws |
Citation | Thin-Walled Structures, 2016, v. 98, p. 212-229 How to Cite? |
Persistent Identifier | http://hdl.handle.net/10722/250299 |
ISSN | 2023 Impact Factor: 5.7 2023 SCImago Journal Rankings: 1.527 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | CAI, Y | - |
dc.contributor.author | Young, B | - |
dc.date.accessioned | 2017-12-20T09:23:43Z | - |
dc.date.available | 2017-12-20T09:23:43Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Thin-Walled Structures, 2016, v. 98, p. 212-229 | - |
dc.identifier.issn | 0263-8231 | - |
dc.identifier.uri | http://hdl.handle.net/10722/250299 | - |
dc.language | eng | - |
dc.publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/tws | - |
dc.relation.ispartof | Thin-Walled Structures | - |
dc.rights | Posting accepted manuscript (postprint): © <year>. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Bearing strength | - |
dc.subject | Bolt hole deformation | - |
dc.subject | Bolted connection | - |
dc.subject | Finite element analysis | - |
dc.subject | Reliability analysis | - |
dc.subject | Stainless steel | - |
dc.title | Bearing Factors of Cold-formed Stainless Steel Double Shear Bolted Connections at Elevated Temperatures | - |
dc.type | Article | - |
dc.identifier.email | Young, B: young@hku.hk | - |
dc.identifier.authority | Young, B=rp00208 | - |
dc.identifier.doi | 10.1016/j.tws.2015.04.021 | - |
dc.identifier.scopus | eid_2-s2.0-84929427744 | - |
dc.identifier.hkuros | 283576 | - |
dc.identifier.volume | 98 | - |
dc.identifier.spage | 212 | - |
dc.identifier.epage | 229 | - |
dc.identifier.isi | WOS:000366767200019 | - |
dc.publisher.place | United Kingdom | - |
dc.identifier.issnl | 0263-8231 | - |