Article: Single-needle lateral sacroplasty technique
Title | Single-needle lateral sacroplasty technique |
---|---|
Authors | |
Issue Date | 2019 |
Publisher | American Society of Neuroradiology. The Journal's web site is located at http://www.ajnr.org |
Citation | American Journal of Neuroradiology, 2019, v. 40 n. 2, p. 382-385 How to Cite? |
Abstract | Sacral insufficiency fractures result in significant morbidity, and percutaneous sacroplasty has emerged as a promising technique for their treatment. We present a technical note regarding our method of treating these fractures using a “single-needle” lateral technique with a combination of conebeam CT and biplane fluoroscopy. We treated 10 patients, in whom the median Visual Analog Scale pain score decreased from 7.0 to 0 (P < .001). We concluded that single-needle sacroplasty is feasible and safe using this technique. |
Persistent Identifier | http://hdl.handle.net/10722/266047 |
ISSN | 2023 Impact Factor: 3.1 2023 SCImago Journal Rankings: 1.020 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nicholson, PJ | - |
dc.contributor.author | Hilditch, CA | - |
dc.contributor.author | Brinjikji, W | - |
dc.contributor.author | Tsang, COA | - |
dc.contributor.author | Smith, R | - |
dc.date.accessioned | 2018-12-17T02:16:38Z | - |
dc.date.available | 2018-12-17T02:16:38Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | American Journal of Neuroradiology, 2019, v. 40 n. 2, p. 382-385 | - |
dc.identifier.issn | 0195-6108 | - |
dc.identifier.uri | http://hdl.handle.net/10722/266047 | - |
dc.description.abstract | Sacral insufficiency fractures result in significant morbidity, and percutaneous sacroplasty has emerged as a promising technique for their treatment. We present a technical note regarding our method of treating these fractures using a “single-needle” lateral technique with a combination of conebeam CT and biplane fluoroscopy. We treated 10 patients, in whom the median Visual Analog Scale pain score decreased from 7.0 to 0 (P < .001). We concluded that single-needle sacroplasty is feasible and safe using this technique. | - |
dc.language | eng | - |
dc.publisher | American Society of Neuroradiology. The Journal's web site is located at http://www.ajnr.org | - |
dc.relation.ispartof | American Journal of Neuroradiology | - |
dc.title | Single-needle lateral sacroplasty technique | - |
dc.type | Article | - |
dc.identifier.email | Tsang, COA: acotsang@hku.hk | - |
dc.identifier.authority | Tsang, COA=rp01519 | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.3174/ajnr.A5884 | - |
dc.identifier.pmid | 30442694 | - |
dc.identifier.scopus | eid_2-s2.0-85061511494 | - |
dc.identifier.hkuros | 296371 | - |
dc.identifier.volume | 40 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 382 | - |
dc.identifier.epage | 385 | - |
dc.identifier.isi | WOS:000458569700034 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 0195-6108 | - |