Article: The impact of central lung distance, maximal heart distance, and radiation technique on the volumetric dose of the lung and heart for intact breast radiation.

TitleThe impact of central lung distance, maximal heart distance, and radiation technique on the volumetric dose of the lung and heart for intact breast radiation.
Authors
Issue Date2002
Citation
International journal of radiation oncology, biology, physics, 2002, v. 54, n. 3, p. 963-971 How to Cite?
AbstractPURPOSE: To investigate the impact of radiographic parameter and radiation technique on the volumetric dose of lung and heart for intact breast radiation. METHODS AND MATERIALS: Forty patients with both two-dimensional (2D) and computed tomographic (CT) simulations were enrolled in the study. Central lung distance (CLD), maximal heart distance (MHD), and maximal heart length (MHL) were measured under virtual simulation. Four plans were compared for each patient. Plan A used a traditional 2D tangential setup. Plan B used clinical target volume (CTV) based three-dimensional (3D) planning. Both plans C and D used a combination of a medial breast field with shallow tangents. Plan D is a further modification of plan C. RESULTS: Under the traditional tangential setup, the mean ipsilateral lung dose and volume at 20, 30, and 40 Gy correlated linearly with CLD (R = 0.85 approximately 0.91). The mean ipsilateral lung dose (Gy) approximated 4 times the CLD value (cm), whereas the percentage volume (%) of ipsilateral lung at 20, 30, and 40 Gy was about 10 times the CLD (cm). The mean heart dose and percentage volume at 20, 30, and 40 Gy correlated with MHD (R = 0.76 approximately 0.80) and MHL (R = 0.65 approximately 0.75). The mean heart dose (Gy) approximated 3 times the MHD value (cm), and the percentage volume (%) of the heart at 10, 20, 30, and 40 Gy was about 6 times MHD (cm). Radiation technique impacted lung and heart dose. The 3D tangential plan (plan B) failed to reduce the volumetric dose of lung and heart from that of the 2D plan (plan A). The medial breast techniques (plans C and D) significantly decreased the volume of lung and heart receiving high doses (30 and 40 Gy). Plan D further decreased the 20 Gy volumes. By use of the medial breast technique, the lung and heart dose were not impacted by original CLD and MHD/MHL. Therefore, the improvement from the tangential technique was more remarkable for patients with CLD >or= 3.0 cm (p < 0.001). CONCLUSIONS: The CLD and MHD impact the volumetric dose of lung and heart. The application of 3D planning for tangential breast irradiation does not decrease heart and lung dose. Adding a medial breast port significantly decreases percentage volume (PV) of lung and heart receiving high doses, especially when the CLD is excessive.
Persistent Identifierhttp://hdl.handle.net/10722/266839
ISSN
2023 Impact Factor: 6.4
2023 SCImago Journal Rankings: 1.992
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorKong, Feng Ming-
dc.contributor.authorKlein, Eric E.-
dc.contributor.authorBradley, Jeffrey D.-
dc.contributor.authorMansur, David B.-
dc.contributor.authorTaylor, Marie E.-
dc.contributor.authorPerez, Carlos A.-
dc.contributor.authorMyerson, Robert J.-
dc.contributor.authorHarms, William B.-
dc.date.accessioned2019-01-31T07:19:46Z-
dc.date.available2019-01-31T07:19:46Z-
dc.date.issued2002-
dc.identifier.citationInternational journal of radiation oncology, biology, physics, 2002, v. 54, n. 3, p. 963-971-
dc.identifier.issn0360-3016-
dc.identifier.urihttp://hdl.handle.net/10722/266839-
dc.description.abstractPURPOSE: To investigate the impact of radiographic parameter and radiation technique on the volumetric dose of lung and heart for intact breast radiation. METHODS AND MATERIALS: Forty patients with both two-dimensional (2D) and computed tomographic (CT) simulations were enrolled in the study. Central lung distance (CLD), maximal heart distance (MHD), and maximal heart length (MHL) were measured under virtual simulation. Four plans were compared for each patient. Plan A used a traditional 2D tangential setup. Plan B used clinical target volume (CTV) based three-dimensional (3D) planning. Both plans C and D used a combination of a medial breast field with shallow tangents. Plan D is a further modification of plan C. RESULTS: Under the traditional tangential setup, the mean ipsilateral lung dose and volume at 20, 30, and 40 Gy correlated linearly with CLD (R = 0.85 approximately 0.91). The mean ipsilateral lung dose (Gy) approximated 4 times the CLD value (cm), whereas the percentage volume (%) of ipsilateral lung at 20, 30, and 40 Gy was about 10 times the CLD (cm). The mean heart dose and percentage volume at 20, 30, and 40 Gy correlated with MHD (R = 0.76 approximately 0.80) and MHL (R = 0.65 approximately 0.75). The mean heart dose (Gy) approximated 3 times the MHD value (cm), and the percentage volume (%) of the heart at 10, 20, 30, and 40 Gy was about 6 times MHD (cm). Radiation technique impacted lung and heart dose. The 3D tangential plan (plan B) failed to reduce the volumetric dose of lung and heart from that of the 2D plan (plan A). The medial breast techniques (plans C and D) significantly decreased the volume of lung and heart receiving high doses (30 and 40 Gy). Plan D further decreased the 20 Gy volumes. By use of the medial breast technique, the lung and heart dose were not impacted by original CLD and MHD/MHL. Therefore, the improvement from the tangential technique was more remarkable for patients with CLD >or= 3.0 cm (p < 0.001). CONCLUSIONS: The CLD and MHD impact the volumetric dose of lung and heart. The application of 3D planning for tangential breast irradiation does not decrease heart and lung dose. Adding a medial breast port significantly decreases percentage volume (PV) of lung and heart receiving high doses, especially when the CLD is excessive.-
dc.languageeng-
dc.relation.ispartofInternational journal of radiation oncology, biology, physics-
dc.titleThe impact of central lung distance, maximal heart distance, and radiation technique on the volumetric dose of the lung and heart for intact breast radiation.-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0360-3016(02)03741-0-
dc.identifier.pmid12377351-
dc.identifier.scopuseid_2-s2.0-0036835101-
dc.identifier.volume54-
dc.identifier.issue3-
dc.identifier.spage963-
dc.identifier.epage971-
dc.identifier.isiWOS:000178715200043-
dc.identifier.issnl0360-3016-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats