Article: Prospective clinical trial to evaluate safety and feasibility of using a single port flexible robotic system for transoral head and neck surgery
Title | Prospective clinical trial to evaluate safety and feasibility of using a single port flexible robotic system for transoral head and neck surgery |
---|---|
Authors | |
Keywords | Robotic surgery Single port Transoral robotic surgery TORS Clinical trialTransoral |
Issue Date | 2019 |
Publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/oraloncology |
Citation | Oral Oncology, 2019, v. 94, p. 101-105 How to Cite? |
Abstract | Introduction:
The aim of this study was to determine the clinical safety and feasibility of a novel single-port flexible robot for Transoral Robotic Surgery (TORS).
Materials and methods:
This was a prospective phase II / IDEAL stage 2 clinical trial of both benign and malignant lesions of the head and neck. The primary endpoint included conversion rates and perioperative complications within 30 days following surgery. The study was registered on www.ClinicalTrials.gov (NCT03010813). The Fisher’s exact test and Mann-Whitney U test were used to compare categorical, and non-parametric data for the trial. A p value <0.05 was considered to be statistically significant. Statistical analysis was performed with SPSS 20.0 (IBM Corp., Armonk, New York)
Results:
Twenty-one patients safely underwent TORS with the da Vinci SP (Intuitive Surgical Inc., Sunnyvale, CA) demonstrating the feasibility of access to the nasopharynx, oropharynx, larynx and hypopharynx. There were no conversions of the robotic surgical system. There were no serious adverse events or adverse events related to the use of the robot at 30-day follow-up for all patients.
Conclusions:
In a prospective Phase II clinical trial, a novel single-port flexible robotic system appears safe and feasible to use for transoral endoscopic head and neck surgery to access the nasopharynx, oropharynx, larynx and hypopharynx. |
Persistent Identifier | http://hdl.handle.net/10722/272997 |
ISSN | 2023 Impact Factor: 4.0 2023 SCImago Journal Rankings: 1.257 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chan, JYK | - |
dc.contributor.author | Tsang, RKY | - |
dc.contributor.author | Holsinger, FC | - |
dc.contributor.author | Tong, MCF | - |
dc.contributor.author | Ng, CWK | - |
dc.contributor.author | Chiu, PWY | - |
dc.contributor.author | Ng, SSM | - |
dc.contributor.author | Wong, EWY | - |
dc.date.accessioned | 2019-08-06T09:20:38Z | - |
dc.date.available | 2019-08-06T09:20:38Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Oral Oncology, 2019, v. 94, p. 101-105 | - |
dc.identifier.issn | 1368-8375 | - |
dc.identifier.uri | http://hdl.handle.net/10722/272997 | - |
dc.description.abstract | Introduction: The aim of this study was to determine the clinical safety and feasibility of a novel single-port flexible robot for Transoral Robotic Surgery (TORS). Materials and methods: This was a prospective phase II / IDEAL stage 2 clinical trial of both benign and malignant lesions of the head and neck. The primary endpoint included conversion rates and perioperative complications within 30 days following surgery. The study was registered on www.ClinicalTrials.gov (NCT03010813). The Fisher’s exact test and Mann-Whitney U test were used to compare categorical, and non-parametric data for the trial. A p value <0.05 was considered to be statistically significant. Statistical analysis was performed with SPSS 20.0 (IBM Corp., Armonk, New York) Results: Twenty-one patients safely underwent TORS with the da Vinci SP (Intuitive Surgical Inc., Sunnyvale, CA) demonstrating the feasibility of access to the nasopharynx, oropharynx, larynx and hypopharynx. There were no conversions of the robotic surgical system. There were no serious adverse events or adverse events related to the use of the robot at 30-day follow-up for all patients. Conclusions: In a prospective Phase II clinical trial, a novel single-port flexible robotic system appears safe and feasible to use for transoral endoscopic head and neck surgery to access the nasopharynx, oropharynx, larynx and hypopharynx. | - |
dc.language | eng | - |
dc.publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/oraloncology | - |
dc.relation.ispartof | Oral Oncology | - |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.subject | Robotic surgery | - |
dc.subject | Single port | - |
dc.subject | Transoral robotic surgery | - |
dc.subject | TORS | - |
dc.subject | Clinical trialTransoral | - |
dc.title | Prospective clinical trial to evaluate safety and feasibility of using a single port flexible robotic system for transoral head and neck surgery | - |
dc.type | Article | - |
dc.identifier.email | Tsang, RKY: rkytsang@hku.hk | - |
dc.identifier.authority | Tsang, RKY=rp01386 | - |
dc.description.nature | published_or_final_version | - |
dc.identifier.doi | 10.1016/j.oraloncology.2019.05.018 | - |
dc.identifier.pmid | 31178203 | - |
dc.identifier.scopus | eid_2-s2.0-85066295147 | - |
dc.identifier.hkuros | 300934 | - |
dc.identifier.volume | 94 | - |
dc.identifier.spage | 101 | - |
dc.identifier.epage | 105 | - |
dc.identifier.isi | WOS:000470244300015 | - |
dc.publisher.place | United Kingdom | - |
dc.identifier.issnl | 1368-8375 | - |