File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Balloon dacryoplasty in internal ostium stenosis after endoscopic dacryocystorhinostomy

TitleBalloon dacryoplasty in internal ostium stenosis after endoscopic dacryocystorhinostomy
Authors
Issue Date2014
Citation
Ophthalmic Plastic and Reconstructive Surgery, 2014, v. 30, n. 1, p. 7-10 How to Cite?
AbstractPURPOSE: To determine the effectiveness of balloon dacryoplasty in the treatment of internal ostium stenosis after endoscopic dacryocystorhinostomy (EnDCR). METHODS: A retrospective, noncomparative interventional case series of patients who underwent balloon dacryoplasty for post-EnDCR internal ostium stenosis were included. A balloon catheter was used in all procedures, with bicanalicular silicone intubation. Patient records were reviewed and data analyzed. Anatomical success was defined by functional endoscopic dye test, and functional success was defined as a subjective improvement in symptoms at last follow up. RESULTS: Nineteen lacrimal systems of 18 consecutive patients were studied between July 2007 and September 2012. At a mean follow up of 20 months (range, 3-53 months), anatomical success rate was 84% (16/19 systems), whereas functional success was 74% (14/19 systems). No major complication was observed. CONCLUSIONS: Balloon dacryoplasty is a minimally invasive procedure in the treatment of post-EnDCR internal ostium stenosis. It is a simple, safe procedure and can provide symptomatic relief to some of these patients. It can be considered as a treatment option for patients demonstrated with internal ostium stenosis after EnDCR.
Persistent Identifierhttp://hdl.handle.net/10722/281929
ISSN
2023 Impact Factor: 1.2
2023 SCImago Journal Rankings: 0.472
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLee, Allie-
dc.contributor.authorAli, Mohammad Javed-
dc.contributor.authorLi, Emmy Yuen Mei-
dc.contributor.authorWong, Alex Chun Wah-
dc.contributor.authorYuen, Hunter Kwok Lai-
dc.date.accessioned2020-04-09T09:19:08Z-
dc.date.available2020-04-09T09:19:08Z-
dc.date.issued2014-
dc.identifier.citationOphthalmic Plastic and Reconstructive Surgery, 2014, v. 30, n. 1, p. 7-10-
dc.identifier.issn0740-9303-
dc.identifier.urihttp://hdl.handle.net/10722/281929-
dc.description.abstractPURPOSE: To determine the effectiveness of balloon dacryoplasty in the treatment of internal ostium stenosis after endoscopic dacryocystorhinostomy (EnDCR). METHODS: A retrospective, noncomparative interventional case series of patients who underwent balloon dacryoplasty for post-EnDCR internal ostium stenosis were included. A balloon catheter was used in all procedures, with bicanalicular silicone intubation. Patient records were reviewed and data analyzed. Anatomical success was defined by functional endoscopic dye test, and functional success was defined as a subjective improvement in symptoms at last follow up. RESULTS: Nineteen lacrimal systems of 18 consecutive patients were studied between July 2007 and September 2012. At a mean follow up of 20 months (range, 3-53 months), anatomical success rate was 84% (16/19 systems), whereas functional success was 74% (14/19 systems). No major complication was observed. CONCLUSIONS: Balloon dacryoplasty is a minimally invasive procedure in the treatment of post-EnDCR internal ostium stenosis. It is a simple, safe procedure and can provide symptomatic relief to some of these patients. It can be considered as a treatment option for patients demonstrated with internal ostium stenosis after EnDCR.-
dc.languageeng-
dc.relation.ispartofOphthalmic Plastic and Reconstructive Surgery-
dc.titleBalloon dacryoplasty in internal ostium stenosis after endoscopic dacryocystorhinostomy-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1097/IOP.0b013e3182a74e1d-
dc.identifier.pmid24317099-
dc.identifier.scopuseid_2-s2.0-84893689111-
dc.identifier.volume30-
dc.identifier.issue1-
dc.identifier.spage7-
dc.identifier.epage10-
dc.identifier.eissn1537-2677-
dc.identifier.isiWOS:000335559600007-
dc.identifier.issnl0740-9303-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats